Preferred Language
Articles
/
tBbHT4kBVTCNdQwCfIi7
Synthesis and Characterization of Heterocyclic Compounds-Based Liquid Crystals
...Show More Authors

This research includes the synthesis, characterization, and investigation of liquid crystalline properties of new rod-shaped liquid crystal compounds 1,4- phenylene bis(2-(5-(four-alkoxybenzylidene)-2,4-dioxothiazolidin-3- yl)acetate), prepared thiazolidine-2,4-dione (I) by the thiourea reaction with chloroacetic acid and water in the presence of the concentrated hydrochloric acid. The n-alkoxy benzaldehyde (II)n synthesized from the reacted 4- hydreoxybenzaldehyde and n-alkyl bromide with potassium hydroxide, and then the compound (I) was reacted with (II)n in the presence of piperidine to produce compounds (III)n. Also, hydroquinone was converted into a corresponding compound (IV) by refluxing with two moles of chloracetyl chloride in pyridine and DMF. After that, the compounds (III)n was interacted with sodium acetate to form compounds (V)n. FT-IR and 1H-NMR spectroscopy were really used to determine the structures of the produced substances. By using the polarized optical microscopy, these mesogens' mesomorphic characteristics were studied (POM). The produced compounds displayed enantiotropic liquid crystal phases, while the substances (V)6–8 displayed a smectic enantiotropy in a variation on the nematic phases.

Preview PDF
Quick Preview PDF
Publication Date
Mon Jun 08 2020
Journal Name
Research Journal Of Chemistry And Environment
High Performance Liquid Chromatographic and Areaunder Curve spectrophotometric Methods forEstimation of Cefixime in Pure and MarketedFormulation: A Comparative Study
...Show More Authors

Cefixime is an antibiotic useful for treating a variety ofmicroorganism infections. In the present work, tworapid, specific, inexpensive and nontoxic methods wereproposed for cefixime determination. Area under curvespectrophotometric and HPLC methods were depictedfor the micro quantification of Cefixime in highly pureand local market formulation. The area under curve(first technique) used in calculation of the cefiximepeak using a UV-visible spectrophotometer.The HPLC (2nd technique) was depended on thepurification of Cefixime by a C18 separating column250mm (length of column) × 4.6 mm (diameter)andusing methanol 50% (organic modifier) and deionizedwater 50% as a mobile phase. The isocratic flow withrate of 1 mL/min was applied, the temper

... Show More
Publication Date
Sat Mar 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Preparation, Characterization, and Properties of Barium Titanate
...Show More Authors

View Publication Preview PDF
Publication Date
Sat Oct 19 2024
Journal Name
European Journal Of Human Genetics
Epigenomic and phenotypic characterization of DEGCAGS syndrome
...Show More Authors

View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Wed Oct 07 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Anti-Urease Activity of Essential oil and Phenolic compounds of Thymus vulgaris, Melaleuca alternifolia and Betula pendula against Proteus mirabilis isolates
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
International Journal Of Drug Delivery Technology
Phytochemical Investigation and Pharmacological Activity of Solidago canadensis L. against H1N1 Virus, involving the Separation and Identification of Three New Compounds
...Show More Authors

Scopus (1)
Scopus
Publication Date
Thu Nov 01 2018
Journal Name
Environmental Technology & Innovation
Extraction of glycyrrhizin from licorice (Glycyrrhiza Glabra L.) by bulk liquid membrane
...Show More Authors

In this work, the extraction of glycyrrhizin from Licorice using bulk liquid membrane technique was developed and optimized. The effect of various parameters such as pH of stripping and donor solutions, temperature, stirring speed and kinetic parameters were investigated. Moreover, to study the impact of the polarity of membrane solvent, two types of extraction solvents were used as a membrane solvent: n-Hexane was used as a non-polar solvent and 1-Hexanol was as a polar solvent. The optimum extraction condition was found (95.53%) using 1-Hexanol, rotating speed was 400 rpm, and pH of the acceptor and donor solutions were 8 and 5.5, respectively. The reaction kinetics constants ( and ) for the transport of glycyrrhizin from the donor pha

... Show More
View Publication
Scopus (18)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Mon Sep 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of-Copper Ions-from Aqueous Solution Using Liquid-Surfactant-Membrane Technique
...Show More Authors

Extraction of copper (Cu) from aqueous solution utilizing Liquid Membrane technology (LM) is more effective than precipitation method that forms sludge and must be disposed of in landfills. In this work, we have formulated a liquid surfactant membrane (LSM) that uses kerosene oil as the main diluent of LSM to remove copper ions from the aqueous waste solution through di- (2-ethylhexyl) phosphoric acid - D2EHPA- as a carrier. This technique displays several advantages including one-stage extraction and stripping process, simple operation, low energy requirement, and. In this study, the LSM process was used to transport Cu (II) ions from the feed phase to the stripping phase, which was prepared, using H2SO4. For LSM p

... Show More
View Publication Preview PDF
Crossref (11)
Crossref
Publication Date
Tue Mar 30 2010
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Minimization of Toxic Ions in Waste Water Using Emulsion Liquid Membrane Technique
...Show More Authors

In the present study, the removal of zinc from synthetic waste water using emulsion liquid membrane extraction technique was investigated. Synthetic surfactant solution is used as the emulsifying agent. Diphenylthiocarbazon (ditizone) was used as the extracting agent dissolved in carbon tetrachloride as the organic solvent and sulfuric acid is used as the stripping agent. The parameters that influence the extraction percentage of Zn+2 were studied. These are the ratio of volume of organic solvent to volume of aqueous feed (0.5-4), ratio of volume of surfactant solution to volume of aqueous feed (0.2-1.6), pH of the aqueous feed solution (5-10), mixing intensity (100-1000) rpm, concentration of extracting agent (20-400) ppm, surfactant co

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Process Optimization Study of Pb(II) Removal by Bulk Liquid Membrane (BLM)
...Show More Authors

   Box-Wilson experimental design method was employed to optimized lead ions removal efficiency by bulk liquid membrane (BLM) method. The optimization procedure was primarily based on four impartial relevant parameters: pH of feed phase (4-6), pH of stripping phase (9-11), carrier concentration TBP (5-10) %, and initial metal concentration (60-120 ppm). maximum recovery efficiency of lead ions is 83.852% was virtually done following thirty one-of-a-kind experimental runs, as exact through 24-Central Composite Design (CCD). The best values for the aforementioned four parameters, corresponding to the most restoration efficiency were: 5, 10, 7.5% (v/v), and 90 mg/l, respectively. The obtained experimental data had been

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
High performance liquid chromatographic method for the determination of guaifenesin in pharmaceutical syrups and in environmental samples
...Show More Authors

A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml res

... Show More
View Publication Preview PDF
Crossref