Objective. This study aimed to evaluate and compare the force degradation of two types of elastomeric chains following different periods of immersion in zinc-containing mouthwashes. Materials and Methods. Four hundred and forty pieces of Elasto-Force and Super Elasto-Force elastomeric chains were divided into two control and eight experimental groups. The pieces were stretched to 25 mm on pins mounted on an acrylic block and stored in distilled water at 37°C. The experimental groups were immersed in four different types of mouthwash for one minute twice a day throughout the test period. Ten continuous thermocycles per day between cold and hot water baths (5–55°C) were carried out. Forces were measured at six-time intervals (initial, 24 hours, 1, 3, 6, and 8 weeks). The mean force was calculated and compared among different elastomeric chains, mouthwashes, and times using the t-test and one-way ANOVA test followed by Tukey’s HSD test. The level of significance was set at 0.05. Results. Both types of elastomeric chains had significant force degradation over time (74–79% at 8 weeks). The Super Elasto-Force generated a higher force level than the Elasto-Force elastomeric chain at all time points. SmartMouth Clinical DDS mouthwash had a significantly lower effect on force degradation than other mouthwashes with no significant difference compared to control groups. Conclusions. Depending on these results: there is no clinically significant difference between both types of elastomeric chains, although Super Elasto-Force delivered a higher force level. The pH of the mouthwashes could play a role in force degradation over time, rather than other ingredients including zinc. The SmartMouth mouthwash had the minimum effect on force degradation of elastomeric chains, followed by Halita, Listerine Total Care Zero, and Breath Rx, respectively.
Background. Implant insertion in regions with poor bone quantity, such as the posterior maxilla, is potentially associated with an increased rate of implant failure. Calcium sulfate can be used as the coating material for commercially pure titanium (CpTi) and as the bone graft material around implants when bound to eggshell powder to enhance the bone quality and quantity of bone defect regions. This study performed a torque removal test to evaluate the effectiveness of eggshell powder as a bone substitute for filling bone defects around CpTi-coated implants coated with nanocrystalline calcium sulfate. Materials and Methods. Eighty screw implant designs were used in the tibiae of 20 white New Zealand rabbits. A total of uncoated 20 s
... Show MoreThis research investigates manganese (Mn) extraction from Electric Arc Furnace Steel Slag (EAFS) by using the Liquid-liquid extraction (LLE) method. The chemical analysis was done on the slag using X-ray fluorescence, X-ray diffraction, and atomic absorption spectroscopy. This work consisted of two parts: the first was an extensive study of the effect of variables that can affect the leaching process rate for Mn element from slag (reaction time, nitric acid concentration, solid to liquid ratio, and stirring speed), and the second part evaluates the extraction of Mn element from leached solution. The results showed the possibility of leaching 83.5 % of Mn element from the slag at a temperature of 25°C, nitric acid co
... Show MoreEncasing glass fiber reinforced polymer (GFRP) beam with reinforced concrete (RC) improves stability, prevents buckling of the web, and enhances the fire resistance efficiency. This paper provides experimental and numerical investigations on the flexural performance of RC specimens composite with encased pultruded GFRP I-sections. The effect of using shear studs to improve the composite interaction between the GFRP beam and concrete was explored. Three specimens were tested under three-point loading. The deformations, strains in the GFRP beams, and slippages between the GFRP beams and concrete were recorded. The embedded GFRP beam enhanced the peak loads by 65% and 51% for the composite specimens with and without shear connectors,
... Show MoreThe complexity and partially defined nature of jet grouting make it hard to predict the performance of grouted piles. So the trials of cement injection at a location with similar soil properties as the erecting site are necessary to assess the performance of the grouted piles. Nevertheless, instead of executing trial-injected piles at the pilot site, which wastes money, time, and effort, the laboratory cement injection devices are essential alternatives for evaluating soil injection ability. This study assesses the performance of a low-pressure laboratory grouting device by improving loose sandy soil injected using binders formed of Silica Fume (SF) as a chemical admixture (10% of Ordinary Portland Cement OPC mass) to di
... Show MoreIn this study, the flexural performance of a new composite beam–slab system filled with concrete material was investigated, where this system was mainly prepared from lightweight cold-formed steel sections of a beam and a deck slab for carrying heavy floor loads as another concept of a conventional composite system with a lower cost impact. For this purpose, seven samples of a profile steel sheet–dry board deck slab (PSSDB/PDS) carried by a steel cold-formed C-purlins beam (CB) were prepared and named “composite CBPDS specimen”, which were tested under a static bending load. Specifically, the effects of the profile steel sheet (PSS) direction (parallel or perpendicular to the span of the specimen) using different C-purlins c
... Show MoreThis study presents a novel, custom‑built fluorescence detector for the precise determination of chloride and iodide ions based on their quenching effect on fluorescein. The detection system incorporates eight blue LEDs irradiation sources arranged at 0–90° angles relative to twin solar cell detectors connected. Two fluorescence quenching strategies were developed. The injected‑mixture mode (IMFQ) exhibited linear ranges of 0.00–1.00 mM for Cl⁻ and 0.00–1.25 mM for I⁻, with detection limits of 20 µM and 10 µmol L⁻¹, respectively. The continuous‑flow mode (CFFQ) demonstrated superior sensitivity with a dispersion factor of 1.33, wider linear ranges (0.1–6.0 m
this paper consists of three sections, Section one deals with the most important difficulties and characteristics of English subordinate clauses whereas section two tackles the difficulties faced by the Iraqi EFL students at the third year in the Department of English, College of languages, University of Baghdad in recognizing and producing the subordinate clauses submitting them to a test consisting of two questions (recognition and production). Finally, some pedagogical recommendation of the findings can be found in section four.
The study aims to provide a Suggested model for the application of Virtual Private Network is a tool that used to protect the transmitted data through the Web-based information system, and the research included using case study methodology in order to collect the data about the research area ( Al-Rasheed Bank) by using Visio to design and draw the diagrams of the suggested models and adopting the data that have been collected by the interviews with the bank's employees, and the research used the modulation of data in order to find solutions for the research's problem.
The importance of the study Lies in dealing with one of the vital topics at the moment, namely, how to make the information transmitted via
... Show More