In every country in the world, there are a number of amputees who have been exposed to some accidents that led to the loss of their upper limbs. The aim of this study is to suggest a system for real-time classification of five classes of shoulder girdle motions for high-level upper limb amputees using a pattern recognition system. In the suggested system, the wavelet transform was utilized for feature extraction, and the extreme learning machine was used as a classifier. The system was tested on four intact-limbed subjects and one amputee, with eight channels involving five electromyography channels and three-axis accelerometer sensor. The study shows that the suggested pattern recognition system has the ability to classify the shoulder girdle motions for high-level upper limb motions with 88.4% average classification accuracy for four intact-limbed subjects and 92.8% classification accuracy for one amputee by combining electromyography and accelerometer channels. The outcomes of this study may suggest that the proposed pattern recognition system can help to provide control signals to drive a prosthetic arm for high-level upper limb amputees.
Research includes evaluation of projects implemented and which entered into trial operation period in accordance with the evaluation criteria and of (cost, quality and time) to determine the size deviations gap for the sample of projects during the years of assessment (2011-2012-2013-2014) of each of the three evaluation criteria, and then followed by a calculation the size of the overall gap to the problem based on the research problem to determine deviations from the specific implementation of each project by answering several questions to answer turns out the reasons for these deviations occur.
The importance of research Focus on the evaluation of received projects from contractors executing the projec
... Show MoreThe research dealt with the study of the element of time in the cinematic language and the role it plays in creating the aesthetic meanings in the documentary film by means of the various structural constructions with which time is constructed. The research included the introduction and the problem of research, which was represented by the following question: (Did the documentary film adopt the values of time formats in the fiction film or it created for itself special linguistic formulations and models which achieve the aesthetic concept?). It also included the importance of research, the need for it and its goal in addition to clarifying the limits of research.The theoretical framework included three sections the first of which is the
... Show MoreThe aim of the current research is to identify the self-control of kindergarten teachers as well as to identify the significance of the differences according to a variable (years of service, academic achievement, specialization). Its final paragraphs consist of (35) paragraphs, and its psychometric properties were verified and the tool was applied to a sample of (400) teachers chosen randomly from kindergarten teachers affiliated to the General Directorates of Education in Baghdad, Rusafa, and Karkh for the academic year 2019-2020
In light of the objectives of the current research, the following results were reached
- The current research sample is from kindergarten teachers with self-contro
- There are diffe
This paper represents an experimental study on the application of smart control represented by the use of the fuzzy logic controller. Two-link flexible manipulators that are used in airspace and military applications are made of flexible materials characterized by low frequency and damping ratio. To solve this problem, this paper proposes the use of smart materials (piezoelectric transducers), where each link is bonded with a pair of piezoelectric transducers that act as a sensor and another as an actuator. As the arm vibrates because of the movement generated by the motor, this voltage is controlled by a regulator inside the LABVIEW® 2020 software and sends the output control voltage to the piezoelectric actuator. Experimental results
... Show MoreThe current research aims to verify the relationship and impact of internal control activities as an independent variable in its dimensions (efficiency, training, independence) in making administrative decisions as a responsive variable and its dimensions (identifying and diagnosing the problem, searching for alternatives, evaluating alternatives, choosing the appropriate alternative, implementing the decision, following up Decision and evaluation) in the Kirkuk Water Directorate, as well as to identify the levels of their practices, and then try to come up with a number of recommendations contribute to the strengthening of internal control activities and the process of making administrative decisions of the researched Directorat
... Show MoreMany of mechanical systems are exposed to undesired vibrations, so designing an active vibration control (AVC) system is important in engineering decisions to reduce this vibration. Smart structure technology is used for vibration reduction. Therefore, the cantilever beam is embedded by a piezoelectric (PZT) as an actuator. The optimal LQR controller is designed that reduce the vibration of the smart beam by using a PZT element.
In this study the main part is to change the length of the aluminum cantilever beam, so keep the control gains, the excitation, the actuation voltage, and mechanical properties of the aluminum beam for each length of the smart cantilever beam and observe the behavior and effec
... Show MoreAbstract Background: Dne of the key component of nasal tipplasty is effecter control of naral tip projection. Several cartilage grafts have been decreased for this purpose each had its own advantage and disadvantage. Aim: To evaluate using of double teostrut graft for controlling of tip projection. Patients and Methods: A total number of 170 patients were subjected to primary and secondary rhino plaster between January 2020 to January 2023. Those patients had double Teostrut banner graft for support of their nasal tip and maintaining tip projection after operation. Results: The follow period was ranging between 6-12 months. The shape of the nose was evaluating by patents vernal analogues scale. The average score for patients satisfaction wa
... Show More