Preferred Language
Articles
/
rxaFVocBVTCNdQwCwEbJ
Plasma parameters of Au nano-particles ablated on porous silicon produced via Nd-YAG laser at 355 nm for sensing NH3 gas
...Show More Authors

The current study aimed the syntheses and characterizations of Gold nanoparticles (Au NPs) using a laser ablation Q-switched Nd: YAG laser with a wave-length of 355 nm at a variety of laser pulse energies (E) and deposited on porous silicon (PS). Optical emission spectrometer was used to diagnosed medium air to study gold plasma characteristics and prepared Au nanoparticles. The laser pulse energy influence has been studied on the plasma characteristics in air. The data showed the emergence of the ionic (Au II) spectral emission lines in the gold plasma emission spectrum. XRD has been utilized to examine structural characteristics. Moreover, AFM results 37.2 nm as the mean value of the diameter that is coordinated in a shape similar to the rod that appears for Au NPs, in addition to that, TEM has been an indication of the fact that synthesized Au NPs were spherical with a mean size of particles, ranging from 25 nm to 30 nm. At high laser pulse energy, the intensity of all emission peaks in the air at atmospheric pressure was considerably greater. Finally, variations in the operating temperature associated with the NH3 gas sensor, created from the samples that have been prepared on the sensitivity of the sensor and response time have been evaluated, the maximal sensitivity is nearly 41% concerning Au NPs that have been ablated via laser energy (E) 400 mJ on the porous silicon of the NH3 gas.

Publication Date
Mon Jun 15 2020
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of plasma treatment on some surface properties of acrylic resin polymer
...Show More Authors

Background: Polymer surfaces usually present problems in bonding and finishing due to their low hydrophilicity. The aim of this study is to investigate the effect of plasma treatment with the use of two types of gases (oxygen and argon) on surface roughness, and chemical surface properties of acrylic resin denture base polymer material. Materials and Methods: Three heat cured acrylic resin specimens of (2*8*30 mm) dimensions were prepared for each test carried out in this study. Two tests were conducted, surface roughness test and chemical surface analysis test. Results: Application of plasma treatment increased surface roughness for both oxygen and argon plasma treated acrylic resin specimen groups compared with control untreated group,

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Wed May 29 2019
Journal Name
Iraqi Journal Of Physics
The effect of the cold atmospheric plasma on the number of platelets
...Show More Authors

This study includes the direct influence of (single & multi) dose of Cold Atmospheric Plasma (CAP) on the no. of platelets for mice for different exposure time (15, 30, 60, and 120) sec. the influence of CAP on mice was measured after 1, 2, 3, 7, and 14 day from exposure.
The results obtained in this study indicate that the effect of low doses of CAP on platelets was stimulatory effect in the first few hours from exposure (1day) but the high dose was inhibitory, It was found that after two weeks of exposure that the number of platelets became normal comparable to the control one, and this indicates that plasma effect was removed after this period.

View Publication Preview PDF
Crossref
Publication Date
Mon Oct 05 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Platelet-Rich Plasma on Osseointegration Period of Dental Implants
...Show More Authors

Background: The preparation of Platelet-rich plasma (PRP) is minimally invasive way, simple, low cost to obtain natural autologous growth factors and is now being widely used in different fields of medicine for its ability to increase the regeneration potential of tissue. The aim of this study was to investigate the effect of local application of autologous PRP gel on acceleration rate of osseointegration period by clinical assessment accomplished by determining the changes in implant stability during 3 months healing period using resonance frequency analysis (RFA). Materials and methods: A total of 28 dental implants were inserted in edentulous maxillae or mandibles of 13 patients using a split mouth design, i.e. each patient was received

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 30 2017
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Study the Performance of Nanozeolite NaA on CO2 Gas Uptake
...Show More Authors

The adsorption isotherms and kinetic uptakes of CO2 were measured. Adsorption isotherms were measured at two temperatures 309 K and 333 K and over a pressure range of 1 to 7 bar. Experimental data of CO2 adsorption isotherms were modeled using Langmuir, Freundlich and Temkin. Based on coefficient of correlation it was found that Langmuir isotherm model was well suited with the experimental data of CO2 adsorption isotherms.  In addition, Adsorption kinetic of CO2 mixture with N2 containing 10 % by volume CO2 and 90 % by volume N2 were determined in a temperature 36 °C and under the atmospheric pressure .When the flow rate was increased from

... Show More
View Publication Preview PDF
Publication Date
Sat Apr 09 2016
Journal Name
Photonic Sensors
Parametric Analysis of NO2 Gas Sensor Based on Carbon Nanotubes
...Show More Authors

View Publication
Scopus (41)
Crossref (40)
Scopus Clarivate Crossref
Publication Date
Wed May 01 2024
Journal Name
Journal Of Engineering
Investigation on Natural Convection in a Square Porous Cavity with an Open Side
...Show More Authors

Natural convection in a porous, rectangular hollow full of saturated air was investigated numerically in the current study. The bottom side was warmed with a continuous heat flux, the right side's temperature was kept at (Tc), the left wall was opened to the surroundings, and the top side was insulated. The pertinent filled-out research parameters in the current experiment were four heat flux values (1500, 3000, 4500, and 6000 W/m²) and three Darcy’s numbers (Da1=4.025×10-10, Da2=4.025×10-8, Da3=4.025×10-6). COMSOL Multiphysics 5.5a, using finite elements and a relying Brinkman-Darcy extended model, was employed to resolve government equations. Local thermal balance simulation was assumed in this solution. Energy transfer and

... Show More
View Publication
Scopus (7)
Crossref (5)
Scopus Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Study the Effects of Machining Parameters on Surface Roughness for Free Form Surface Using Taguchi Method
...Show More Authors

The surface finish of the machining part is the mostly important characteristics of products quality and its indispensable customers’ requirement. Taguchi robust parameters designs for optimizing for surface finish in turning of 7025 AL-Alloy using carbide cutting tool has been utilized in this paper. Three machining variables namely; the machining speeds (1600, 1900, and 2200) rpm, depth of cut (0.25, 0.50, 0.75) mm and the feed rates (0.12, 0.18, 0.24) mm/min utilized in the experiments. The other variables were considered as constants. The mean surface finish was utilized as a measuring of surface quality. The results clarified that increasing the speeds reduce the surface roughness, while it rises with increasing the depths and fee

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of Mechanical and Histological Significance of Nano Hydroxyapatite and Nano Zirconium Oxide Coating On the Osseointegration of CP Ti Implants
...Show More Authors

Background: Dental implant considers a unique treatment option for the replacement of missing dentition. The new trend of implants is looking for materials which accelerate bone formation in bone implant interface and enhance osseointegration to provide immediate loading directly after placement and decrease the time period which is disturbs patients and uncomfortable. The aim of the study was to evaluate the effect of nano zirconium oxide (ZrO2) and nano hydroxyapatite (Hap) mixture coating of screw shaped commercially pure titanium (cpTi) implants on bond strength at the bone implant interface with torque removal test and histological analysis in comparison with non coated implants. Materials and methods: Forty screws were machined from c

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Thu Oct 01 2009
Journal Name
Iraqi Journal Of Physics
تأثیر التطعیم بأیونات النیودیمیوم الفعالة Nd+3 على طیف الفلورة لزجاج التلیریت TeO2
...Show More Authors

In the present work, the fabrication techniques of type of Nd +3-glass laser active
media : namely, Neodymium- Tellurite glass, where the glass system(TeO2(1-x) - BaOZnO-
Nd2O3x) for values of (X=1,1.5,2,2.5,3,3.5 wt%) was used.
Measurements have been taken for the signal of fluorescence spectrum of Nd+3- glass
samples. The fluorescence spectrum, for one of the samples, has been taken, after the
sequences of polishing for the out surface.
The results give signal of fluorescence spectrum for the samples. Intensity of the peak of
the signal increases with Nd +3 concentration. The fluorescence at (l=1.06 mm) for one
of the samples has been detected and the fluorescence line width was (100 cm-1). The
cross section

... Show More
View Publication Preview PDF
Publication Date
Mon Aug 03 2020
Journal Name
Digest Journal Of Nanomaterials And Biostructures
PREPARATION OF MIXED In2O3 – CdO THIN FILMS BY CSP TECHNIQUE FOR LIGHT SENSING
...Show More Authors

In this work, chemical spray pyrolysis deposition (CSP) technique was used to prepare a mixed In2O3-CdO thin films with different CdO content (10, 30 and 50)%volume ratio on glass substrates at 150 ᵒC substrate temperature. The surface morphology and structural properties were measured to find the optimum conditions to improve thin films properties for using as photo detector. Current –Time, the sensitivity and response speed vary for each mixture. Samples with 10% vol. CdO content has square pulse response with average rise time nearly 1s and fall time 1s.