Preferred Language
Articles
/
rhcEt40BVTCNdQwC3Bmn
Design and Fabrication of an Electromechanical Tester to Perform Two-dimensional Tensile Testing for Flexible Materials
...Show More Authors

There are many diseases that affect the arteries, especially those related to their elasticity and stiffness, and they can be guessed by estimating and calculating the modulus of elasticity. Hence, the accurate calculation of the elastic modulus leads to an accurate assessment of these diseases, especially in their early stages, which can contribute to the treatment of these diseases early. Most of the calculations used the one-dimensional (1D) modulus of elasticity. From a mechanical point of view, the stresses to which the artery is subjected are not one-dimensional, but three-dimensional. Therefore, estimating at least a two-dimensional (2D) modulus of elasticity will necessarily be more accurate. To the knowledge of researchers, there is a lack of published research on this subject, as well as a paucity of research that designed and implemented a 2D tensile testing device (2DTTD). However, there is no inspection of arterial flexibility and elasticity using the 2DTTD adequately studied before. Therefore, the aim of this work is to design and implement the 2DTTD to scrutinize if there is a difference between the 1D and 2D tensile examination. Different sized rectangular silicone specimens were manually fabricated; they were tested individually using the fabricated 2DTTD, which mainly comprises four actuators synchronously working with the same velocity and axial load force, two at each axis. As expected using the 2DTTD, the dimensions of the specimen remarkably influence the tensile testing results; the strain and stress rates and the modulus of elasticity were influenced. To validate the acquired 2D tensile testing results, the 1D tensile testing was performed using the same fabricated 2DTTD and compared to results gained using another tensile testing apparatus. During the verification process, the input data for models calibration were sufficiently and accurately provided. The results showed reasonable precision and reliability in calculations of the 2D stress and strain rates during the whole deformation process. Each mechanical device that has been used has the possibility to stretch and squeeze the sample and log the change in the specimen elongation. The authors thought that the present experimental methodology was applied to the linear mechanical device successfully, where the encoder that is attached to tested samples was in the principal direction. The present method is used to measure the deformation in a manner that differs from the traditional digital image correlation method, which required a toolset that is more expensive, where it incorporates high-accuracy optical equipment.

Preview PDF
Quick Preview PDF
Publication Date
Wed Jul 01 2020
Journal Name
Journal Of Engineering
An Analytical Solution for the Maximum Tensile Stress and Stress Concentration Factor Investigations for Standard, Asymmetric fillets, Asymmetric Pressure Angle and Profile Shifted Helical and Spur Gears
...Show More Authors

This research introduces a developed analytical method to determine the nominal and maximum tensile stress and investigate the stress concentration factor. The required tooth fillets parametric equations and gears dimensions have been reformulated to take into account the asymmetric fillets radiuses, asymmetric pressure angle, and profile shifting non-standard modifications. An analytical technique has been developed for the determination of tooth weakest section location for standard, asymmetric fillet radiuses, asymmetric pressure angle and profile shifted involute helical and spur gears. Moreover, an analytical equation to evaluate gear tooth-loading angle at any radial distance on the involute profile of spur and hel

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Oct 01 2018
Journal Name
2018 International Conference On Advanced Science And Engineering (icoase)
Real-Time Face Tracking and Recognition System Using Kanade-Lucas-Tomasi and Two-Dimensional Principal Component Analysis
...Show More Authors

View Publication
Scopus (18)
Crossref (9)
Scopus Crossref
Publication Date
Mon Apr 30 2018
Journal Name
Journal Of Theoretical And Applied Information Technology
An efficient artificial fish swarm algorithm with harmony search for scheduling in flexible job-shop problem
...Show More Authors

Flexible job-shop scheduling problem (FJSP) is one of the instances in flexible manufacturing systems. It is considered as a very complex to control. Hence generating a control system for this problem domain is difficult. FJSP inherits the job-shop scheduling problem characteristics. It has an additional decision level to the sequencing one which allows the operations to be processed on any machine among a set of available machines at a facility. In this article, we present Artificial Fish Swarm Algorithm with Harmony Search for solving the flexible job shop scheduling problem. It is based on the new harmony improvised from results obtained by artificial fish swarm algorithm. This improvised solution is sent to comparison to an overall best

... Show More
View Publication Preview PDF
Scopus (3)
Scopus
Publication Date
Thu Oct 01 2015
Journal Name
Journal Of Nanoelectronics And Optoelectronics
Hypothetical Design of Carbon Nanotube Materials Based on [8]Circulene
...Show More Authors

B3LYP/6-31G, DFT method was applied to hypothetical study the design of six carbon nanotube materials based on [8]circulene, through the use of cyclic polymerization of two and three molecules of [8]circulene. Optimized structures of [8]circulene have saddle-shaped. Design of six carbon nanotubes reactions were done by thermodynamically calculating (Δ S, Δ G and Δ H) and the stability of these hypothetical nanotubes depending on the value of HOMO energy level. Nanotubes obtained have the most efficient gap energy, making them potentially useful for solar cell applications.

Publication Date
Fri Aug 02 2024
Journal Name
Engineering, Technology & Applied Science Research
Contributory Factors related to the Tensile Strength of Hot Mix Asphalt Concrete
...Show More Authors

Tensile strength is a critical property of Hot Mix Asphalt (HMA) pavements and is closely related to distresses such as fatigue cracking. This study aims to evaluate methods for assessing fatigue cracking in Asphalt Concrete (AC) mixes. In order to achieve optimum density at different binder contents, the mixes were compressed using a gyratory compactor. Tensile strength was assessed using the Indirect Tensile (IDT) and Semi-Circular Bend (SCB) tests. The results showed that the tensile strength measured by the SCB test was consistently higher than that measured by the IDT test at 25 °C. In addition, the SCB test showed a stronger correlation between increasing binder content and tensile strength. For binder contents ranging from 4

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Feb 25 2024
Journal Name
Baghdad Science Journal
Hybrid Framework To Exclude Similar and Faulty Test Cases In Regression Testing
...Show More Authors

 

Regression testing is a crucial phase in the software development lifecycle that makes sure that new changes/updates in the software system don’t introduce defects or don’t affect adversely the existing functionalities. However, as the software systems grow in complexity, the number of test cases in regression suite can become large which results into more testing time and resource consumption. In addition, the presence of redundant and faulty test cases may affect the efficiency of the regression testing process. Therefore, this paper presents a new Hybrid Framework to Exclude Similar & Faulty Test Cases in Regression Testing (ETCPM) that utilizes automated code analysis techniques and historical test execution data to

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Tue Jan 08 2019
Journal Name
International Journal Of Mechanical Engineering And Technology (ijmet)
MANUFACTURING AND ANALYSIS CUSTOM FOOT ORTHOTIC FOR FLEXIBLE FLATFOOT
...Show More Authors

This paper presents two main parts: The first part involves manufacturing the specimens form composite material for mechanical testing (tensile, flexural and fatigue tests), then design a custom foot orthesis (CFO) and manufacturing from composite lamination (3nylglass 2carbon fiber 3nylglass) for patient suffer from flexible flat foot since birth and over-pronation. The second part of this research involves a design a model of custom foot orthesis in (solid work 2018) and then analysis of custom foot orthosis in engineering analysis program (ANSYS V.18.2).The applied pressure in boundary condition adopted from Force Sensor Resistance (FSR 402 ) in various regions in foot after wearing composite CFO. Used a composite materials in engineerin

... Show More
View Publication
Scopus (2)
Scopus
Publication Date
Wed Oct 05 2011
Journal Name
Iraqi Journal Of Physics
Study of linear shrinkage for siliceous materials to meet insulating requirements
...Show More Authors

Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Aip Conference Proceedings
Design and establishment of an implementation program to simulate the far field propagation for a Gaussian beam of x-ray laser
...Show More Authors

View Publication
Scopus (2)
Crossref (3)
Scopus Crossref
Publication Date
Fri Sep 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
FEM: Mono-implant cement retained crown with two different adhesive materials
...Show More Authors

Background: The finite element method (FEM) is expected to be one of the most effective computational tools for measuring the stress on implant-supported restorations. This study was designed using the 3D-FEM to evaluate the effect of two adhesive luting types of cement on the occlusal stress and deformation of a hybrid crown cemented to a mono-implant. Materials and Method: The mono-screw STL file was imported into the CAD/CAM system library from a database supported by De-Tech Implant Technology. This was to assist in the accurate reproduction of details and design of a simulated implant abutment. Virtually, a digital crown was designed to be cemented on an abutment screw. A minimum occlusal thickness of 1mm and marginal fitting of 1.2

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref