Preferred Language
Articles
/
rRZbZ4cBVTCNdQwCjUkV
Reconstruction of an orthotropic thermal conductivity from non-local heat flux measurements
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Fri Oct 20 2023
Journal Name
Baghdad Science Journal
Synthesis, Characterization , Thermal Studies and Antioxidant Activities of Transition Metal Complexes with Azo Dye ligand
...Show More Authors

Diazotization reaction between 1-(2,4,6-Trihydroxy-phenyl)-ethanone and diazonium salts was carried out resulting in ligand 4-(3-Acetyl-2,4,6-trihydroxy-phenylazo)-N-(5-methyl-isoxazol-3-yl)-benzenesulfonamide, this in turn reacted with the next metal ions (V4+ , Cr3+ , Mn2+ and Cu2+) forming stable complexes with unique geometries such as (Octahedral for both Cr3+ , Mn2+ and Cu2+ ,squar pyramidal for V4+). The creation of such complexes was detected by employing spectroscopic means involving ultraviolet-visible which proved the obtained geometries, fourier transfer proved the formation of azo group and and the coordination with metal ion through it. Pyrolysis (TGA & DSC) studies proved the coordination of water residues with me

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Fri May 01 2015
Journal Name
Journal Of Engineering
Experimental Study of the Thermal Performance of Flat Plate Solar Collectors Array by Different Connection Configurations
...Show More Authors

The current research illustrates experimentally the effect of series and parallel connection (Z-I Configurations) of flat plate water solar collectors array on the thermal performance of closed loop solar heating system. The study includes the effect of changing the water flow rate on the thermal efficiency. The results show that, the collector's efficiency in series connection is higher than the parallel connection within flow rate level less than (100) ℓ/hr. Moreover, the collector efficiency in parallel connection of (I-Configurations) is more than the (Z- Configurations) with increasing the water flow rate .The maximum daily efficiency for parallel (I-Configurations) and (Z- Configurations) are (55%) and (51%) at w

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Environmental Assessment of Polycyclic Aromatic Hydrocarbon Concentrations in Air at Thermal South Power Station of Baghdad
...Show More Authors

Sixteen polycyclic aromatic hydrocarbons (PAHs) concentrations were measured in aerosol samples collected for the period from April 2012 to February 2013 at thermal south power station of Baghdad. Fourty one aerosol sample were extracted with (1:1) dichloromethane and methanol using soxhlet for seventeen hour. The extraction solution was analyzed applying GC/MS. The PAH concentrations outside thermal south power station were higher than those inside it, and higher in summer season than in winter. Naphthalene, pyrene, Anthracene, Indeno [1, 2, 3-cd] pyrene and Phenanthrene were the most abundant PAHs detected in all points at the site sampling. The total polycyclic aromatic hydrocarbon (TPAH) and total suspended particles (TSP) concentrat

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 01 2024
Journal Name
Inorganic Chemistry Communications
Investigation of optical, mechanical, thermal, wettability, and antibacterial activity of polyvinyl alcohol mixed with clay nanoparticles
...Show More Authors

View Publication
Scopus (12)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Mon Mar 07 2022
Journal Name
Journal Of Inorganic And Organometallic Polymers And Materials
Mechanical Characteristics and Thermal Stability of Hybrid Epoxy and Acrylic Polymer Coating/Nanoclay of Various Thicknesses
...Show More Authors

View Publication
Crossref (28)
Crossref
Publication Date
Tue Mar 31 2015
Journal Name
Al-khwarizmi Engineering Journal
Study on Flow Characteristics and Heat Transfer Behavior Around Different Geometrical Corrugated Extended Surfaces
...Show More Authors

Abstract

The current study presents numerical investigation of the fluid (air) flow characteristics and convection heat transfer around different corrugated surfaces geometry in the low Reynolds number region (Re<1000). The geometries are included wavy, triangle, and rectangular. The effect of different geometry parameters such as aspect ratio and number of cycles per unit length on flow field characteristics and heat transfer was estimated and compared with each other. The computerized fluid dynamics package (ANSYS 14) is used to simulate the flow field and heat transfer, solve the governing equations, and extract the results. It is found that the turbulence intensity for rectangular extended surface was larg

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
MIXED CONVECTIVE AND RADIATIVE HEAT TRANSFER IN A HORIZONTAL CONCENTRIC AND ECCENTRIC CYLINDRICAL ANNULI
...Show More Authors

A numerical investigation has been performed to study the effect of eccentricity on unsteady state, laminar aiding mixed convection in a horizontal concentric and eccentric cylindrical annulus. The outer cylinder was kept at a constant temperature
while the inner cylinder was heated with constant heat flux. The study involved numerical solution of transient momentum (Navier-Stokes) and energy equation using finite difference method (FDM), where the body fitted coordinate system (BFC) was
used to generate the grid mesh for computational plane. The governing equations were transformed to the vorticity-stream function formula as for momentum equations and to the temperature and stream function for energy equation.
A computer progra

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
DEVELOPING LAMINAR MIXED CONVECTION HEAT TRANSFER THROUGH VERTICAL CONCENTRIC ANNULI WITH ADIABATIC INNER CYLINDER
...Show More Authors

Theoretical and experimental investigations have been carried out on developing laminar
combined free and forced convection heat transfer in a vertical concentric annulus with uniformly
heated outer cylinder (constant heat flux) and adiabatic inner cylinder for both aiding and opposing
flows. The theoretical investigation involved a mathematical modeling and numerical solution for
two dimensional, symmetric, simultaneously developing laminar air flows was achieved. The
governing equations of motion (continuity, momentum and energy) are solved by using implicit
finite difference method and the Gauss elimination technique. The theoretical work covers heat flux
range from (200 to 1500) W/m2, Re range from 400 to 2000 an

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Nov 01 2021
Journal Name
Energies
Solidification Enhancement in a Triple-Tube Latent Heat Energy Storage System Using Twisted Fins
...Show More Authors

This work evaluates the influence of combining twisted fins in a triple-tube heat exchanger utilised for latent heat thermal energy storage (LHTES) in three-dimensional numerical simulation and comparing the outcome with the cases of the straight fins and no fins. The phase change material (PCM) is in the annulus between the inner and the outer tube, these tubes include a cold fluid that flows in the counter current path, to solidify the PCM and release the heat storage energy. The performance of the unit was assessed based on the liquid fraction and temperature profiles as well as solidification and the energy storage rate. This study aims to find suitable and efficient fins number and the optimum values of the Re and the inlet tem

... Show More
View Publication
Scopus (41)
Crossref (40)
Scopus Clarivate Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Journal Of Economics And Administrative Sciences
The quality of the auditor's report in the local environment in compliance with the requirements of the ISA 701 standard
...Show More Authors

The research aims to demonstrate the quality of the auditor’s report by analyzing a number of models represented by the auditor’s report based on the Iraqi audit evidence and the auditor’s report in light of the application of international auditing standards for the report and the auditor’s report in light of the application of the International Auditing Standard 701, in addition to explaining the impact of applying the International Auditing Standard 701. International Auditing 701 in enhancing the quality of the auditor's report, and in order to reach these goals, a comparison was made on international experiences before and after the application of the standard in addition to the results of the questionnaire distribut

... Show More
View Publication Preview PDF
Crossref