Alloy of (HgTe) has been prepared succesful in evacuated qurtz ampoule at pressure 4×10-5torr, and melting temperature equal to 823K for five days. Thin films of HgTe of thickness 1μm were deposited on NaCl crystal by thermal evaporation technique at room temperature under vacuum about 4×10-5torr as well as investiagtion in the optical porperties included (absorption coefficient , energy gap) of HgTe films and The optical measurements showed that HgTe film has direct energy gap equal to 0.05 eV. The optical constants (n, k, εr, εi) have been measured over will range (6-28)μm.
A series of experiments have been taken out to test the validity of the effect of Aluminum hydrate on its interaction with Aluminum during sintering of aluminum metal matrix. The approach has been shown to be valid and several compositions have been fabricated. The alumina hydrate particle size and the amount of alumina hydrate in the composites are also shown to have an influence on the extent of densification.
The densities for all sintered specimens were measured. It was found that density increases as compaction pressure increases, the density decreases as particles size increases. At 400 MPa there is an optimum particles size which is (90-125) µm to reach maximum density and the density decreases as volume fraction increase
... Show MoreThe Study was achieved adjectives physical and chemical water wells in the district of
Samarra , where a study has 42 sample groundwater in different regions of the judiciary
randomly distributed all over the judiciary and examined in vitro.
The study showed that the quality of groundwater in the general area of study
Kipritateh punctuated Klordih water quality and other quality Bicarboonatih.
Varied the key components of groundwater in the study area in concentrations
between periods of rain and drought, especially because of the cation ion exchange processes
as well as mitigation as a result of filtering rain water and dominated the calcium ion,
followed by sodium.
As for the negative ions has dominated ion s
The orogenic gold deposit of Tamilouw – Haya is hosted by slate and metapelitic rocks within Tehoru metamorphic complex. Gold and polymetallic sulfides mineralization at study area is predominantly formed in the form of veins, stockwork and breccia although minor dissemination is slightly appeared in the rock float samples. They are trapped and controlled by NE-SW and NNE-SSW trending geologic structure occurred during orogeny process from Late Miocene to Pliocene. The common ore minerals assemblage at Tamilouw – Haya deposit are dominated by native gold, chalcopyrite, pyrite, sphalerite, galena, pyrrhotite, tetrahedrite-tennantite (sulphosalt), marcasite,realgar, kalininite and arsenopyrite as hypogene minerals and accompanied by co
... Show MoreThe first chapter includes introduce the research and the problem of the research that there are negligence of some educational institutions and schools management , some parents and supervisors .Also there are some educators who believes that school activities are obstacles means to learning and prevent pupils from studying and understanding the subjects. That may due to social , psychological and educational reasons
The purposes of the researches come from the reports of supervision visits which indicate a lot of difficulties faced by pupils and teachers related to education activities and its influence on in education and the necessity of indentify these difficulties and remedy them
... Show MoreIraqi bentonite is used as main material for preparing ceramic samples with the additions of alumina and magnesia. X-ray diffractions analyses were carried out for the raw material at room temperature. The sequence of mineral phase's transformations of the bentonite for temperatures 1000 ,1100 ,1200 and 1250 ºC reflects that it finally transformed in to mullite 39.18% and cristobalite 62.82%. Samples of different weight constituent were prepared. The effect of its constitutional change reveals through its heat treatments at 1000,1100,1200,1250and 1300ºC .The samples of additions less than 15% of alumina and magnesia could not stand up to 1300ºC while the samples of addition more than 15% are stable .That is shown by analy
... Show MoreAbstract
This work involves the manufacturing of MAX phase materials include V2AlC and Cr2AlC using powder metallurgy as a new class of materials which characterized by regular crystals in lattice. Corrosion behavior of these materials was investigated by Potentiostat to estimate corrosion resistance and compared with the most resistant material represented by SS 316L. The experiments were carried out in 0.01N of NaOH solution at four temperatures in the range of 30–60oC. Polarization resistance values which calculated by Stern-Geary equation indicated that the MAX phase materials more resistant than SS 316L. Also cyclic polarization tests confirme
... Show MoreObjective: To assess mothers' knowledge and practices concerning cholera and their relationship with some
sociodemographic characteristics of those mothers.
Methodology: A sample of (100) mother was selected through a convenience sample for the period of July First
through August 31 2007 '؛
. Data were collected through interview of mothers were visiting PHC centers by using
of constructed questionnaire developed by the researcher that contains (31) item. Reliability and Validity of the
tool were determined through pilot study. A descriptive and inferential statistical approaches were used for data
analysis.
Results: The study indicated that mothers’ knowledge and practices concerning cholera were unacceptable
Objectives: This study aims to determine the disease’s patterns and outcomes of admission among neonates hospitalized at the neonatal care unit in Erbil City, and using the findings as a baseline for neonate’s morbidity and mortality assessment in the future. Methodology: A retrospective study carried out at neonatal care unit of Raparin pediatric teaching hospital. An instrument for data collection developed by researcher included (age, gender, cause of admission, diagnosis and outcome upon discharge and causes of death). Content validity of the instrument was determined through the use of panel ex