This study, which was conducted in the city of Mosul, through collected 1200 samples from the stool of patients with diarrhea attending hospitals and private clinics for the period from the beginning of January 2019 to the end of December 2019, those whose ages ranged from less than a year-60 year, and for both sexes and by reality 700 samples stool for males and 500 samples stool for females. Samples were collected in clean, sterile, and sealed 40ml plastic bottles. Patient information is noted, name of the parasite, history, sex, age, address. The result showed that climate and temperature have a significant effect on increase the incidence of intestinal parasites through the direct effect on the increase in infection rate. This effect was the temperatures are suitable for converting the cyst into the trophoizote and fatal phase . The results showed that the infection rate in Mosul governorate with intestinal parasites is 23.83%,which is Entamoeba histolytica & Giardia lamblia, The result showed the number of infected males 193 with an infection rate (27.57%) which is higher than the number of infected females 93 with an infection rate (18.6%) of the total infections and shown the highest percentage infection of intestinal protozoa, parasites occurred in May it has reached (61%) while the lowest percentage of infection was in January (7%). The showed the percentage of intestinal protozoa, parasites infection, according to the age, the highest rate of infection in age group (0-10) (25.09%) while the age group (10-30) recorded the percentage of infection (21.44%), the age group (30-60) percentage of infection is (19.56%) the percentage of intestinal protozoa, parasites infection, according to the age, the highest rate of infection in age group (0-10) (25.09%) while the age group (10-30) recorded the percentage of infection (21.44%), the age group (30-60) percentage of infection is (19.56%), showed the percentage of intestinal protozoa parasite infection, according to the seasons of year the highest rate of infection in spring (32.66%) while the Summer (30%), the autumn recorded the percentage of infection (22%).
This study included the isolation and diagnosis of Pseudomonas aeruginosa from cases of burns samples. 100 samples were collected from resident patients at Al-Kindi Teaching Hospital, who suffer from different types of burns. Pseudomonas aeruginosa was isolated and diagnosed with 39% of the total samples. The cold and hot aqueous and alcoholic extract of flaxseeds oil was prepared and its inhibitory efficacy has been studied on the growth of isolated Pseudomonas aeruginosa. It is revealed that both extracts of flaxseeds oil had a high inhibitory effect on Pseudomonas aeruginosa growth. The Minimum Inhibitory Concentration (MIC) of flaxseed oil on the studied bacteria was also estimated, which was 25 mg/ml. In conclusion, the efficacy of fla
... Show MoreThe research aims to develop a proposed mechanism for financial reporting on sustainable investment that takes the specificity of these investments.
To achieve this goal, the researcher used (what if scenario) where the future financial statements were prepared for the year 2026, after completion of the sustainable project and operation, as the project requires four years to be completed.
The researcher relied on the results of the researchers collected from various modern sources relevant to the research topic and published on the internet, and the financial data and information obtained to assess the reality of the company's activity and its environmental, social, and economic i
... Show MoreThis paper aims to improve the voltage profile using the Static Synchronous Compensator (STATCOM) in the power system in the Kurdistan Region for all weak buses. Power System Simulation studied it for Engineers (PSS\E) software version 33.0 to apply the Newton-Raphson (NR) method. All bus voltages were recorded and compared with the Kurdistan region grid index (0.95≤V ≤1.05), simulating the power system and finding the optimal size and suitable location of Static Synchronous Compensator (STATCOM)for bus voltage improvement at the weakest buses. It shows that Soran and New Koya substations are the best placement for adding STATCOM with the sizes 20 MVAR and 40 MVAR. After adding STATCOM with the sizes [20MVAR and 40MV
... Show MoreBearing capacity of a concrete pile in fine grained cohesive soils is affected by the degree of saturation of the surrounding soil through the contribution of the matric suction. In addition, the embedded depth and the roughness of the concrete pile surface (expressed as British Pendulum Number BPN) also have their contribution to the shear strength of the concrete pile, consequently its bearing capacity. Herein, relationships among degree of saturation, pile depth, and surface roughness, were proposed as a mathematical model expressed as an equation where the shear strength of a pile can be predicted in terms of degree of saturation, depth, and BPN. Rel
... Show MoreABSTRACT:
Interest rates are one of the important aspects that affect the banking business directly, which is characterized by unstable dynamic dynamics, which must be viewed on a daily and continuous basis through the macroeconomic view, which directly affects the bank’s income realized from loans as interest received or interest paid on its deposits as an expense. Hence the earnings per share. The relationship between interest rates and between net income and earnings per share was measured and a correlation was found between them, and then the effect between them was measured using regression equations and they were applied and th
... Show MoreEvaluating treatment effect on interferon-alpha in female patients with systemic lupus erythematosus: a case-control study
This study aims to show, the strength of steel beam-concrete slab system without using shear connectors (known as a non-composite action), where the effect of the friction force between the concrete slab and the steel beam has been investigated, by using finite element simulation.
The proposed finite element model has been verified based on comparison with an experimental work. Then, the model was adopted to study the system strength with a different steel beam and concrete slab profile. ABAQUS has been adopted in the preparation of all numerical models for this study.
After validation of the numerical models, a parametric study was conducted, with linear and non-linear Regression analysis. An equation re
... Show More