An experiment was conducted to study the effect of the sprayer type according to the source of power and the size of the spray nozzle concerning the quality of the spray produced and fuel consumption.Two types of sprayers were used: a conventional boom sprayer (S1) and a modified (electrified) boom sprayer (S2), along with three sizes of the XR TeeJet 110 spray nozzle (N). The following technical performance indicators were examined: Density of coverage (drops/cm2) using ImageJ software, a 600dpi business card scanner, specifically the ScanShell 800N by CSSN, Inc, and water-sensitive paper (WSP), rate of spray nozzles discharge (ml/min), and fuel consumption (liters/hectare) using a calibrated cylinder, and the percentage of weed control by sampling treated and untreated weeds. The experiment was designed as a complete randomized block design in the order of the system (Nested design). Sprayer type had significant effect on spray coverage and nozzle discharge rate. The conventional boom sprayer resulted in a coverage of 169.5 drops/cm2, while the modified (electrified) boom sprayer achieved only 149.4 drops/cm2. The discharge rate was 707.5 ml/min when using the conventional boom sprayer, compared to 671.2 ml/min with lower pesticide consumption when using the modified (electrified) boom sprayer.The smaller-sized XR TeeJet 110.015 VP nozzle (N1) outperformed the other nozzle sizes in terms of coverage (178.7 drops/cm2), weed control percentage (84.56%), and lower pesticide consumption (lower nozzle discharge) of 490.4 ml/min.
Thermal energy storage is an important component in energy units to decrease the gap between energy supply and demand. Free convection and the locations of the tubes carrying the heat-transfer fluid (HTF) have a significant influence on both the energy discharging potential and the buoyancy effect during the solidification mode. In the present study, the impact of the tube position was examined during the discharging process. Liquid-fraction evolution and energy removal rate with thermo-fluid contour profiles were used to examine the performance of the unit. Heat exchanger tubes are proposed with different numbers and positions in the unit for various cases including uniform and non-uniform tubes distribution. The results show that
... Show MoreAbstract: A home-made dc sputtering is characterized by cathode potential of 250-2500 V and sputtering gas pressures of (3.5×10-2 – 1.5) mbar. This paper studies in experiment the breakdown of argon, nitrogen, and oxygen in a uniform dc electric field at different discharge gaps and cathode potentials. Paschen curves for Argon, Nitrogen, and oxygen are obtained by measuring the breakdown voltage of gas within a stainless steel vacuum chamber with two planar, stainless steel electrodes. The Paschen curves in Ar, N2, and O2 gases show that the breakdown voltage between two electrodes is a function of pd (The product of the pressure inside the chamber and distance between the electrodes). Current-voltage characteristics visualization of the
... Show MoreA gracious invitation was extended to us on 9/11/2002 AD, by the University of Tikrit / the Preparatory Committee, for a symposium (Sheikh Daoud Al-Tikriti, and his Scientific Effects), to participate in it.
The symposium was scheduled to be held on the 25th and 26th of March 2003 AD, but God Almighty decreed that our country be occupied, so the Preparatory Committee set another date for the symposium on 10/21/2003 AD.
It was not possible for the symposium to be held until 25-26/4/2004 AD, and many researchers attended, who were assigned to investigate some manuscripts of Sheikh Dawood (may God have mercy on him) or to write about his personal and scientific biography.
And God (Glory be to Him) did not enable us to attend, becau
Twisted tape insertion in smooth plain tube is one of types of passive methods that is used to enhance heat transfer. Swirl fluid flow inside tube and related heat transfer characteristics are very complex. ANSYS FLUENT (V 16.1) and ASPEN industrial program are used in analyzing this technique for enhancement heat transfer. A circular plain tube has length L=8534mm and 17 mm inner diameter with twisted tape has twist ratio of y = (H/D) = (150/17) =8.8 along with a plain tube were considered for this study. Eight Reynolds numbers (Re) of 784, 1000, 2000, 3000, 4000, 5000, 6000 and 7000 are used to analyze the response of thermal performance. Crude oil API 28 exit temperature, film heat transfer coefficient, Nusselt number
... Show MoreS Ali…, Journal of Physical Education, 2019 - Cited by 1
Twisted tape insertion in the smooth plain tube is one of the types of passive methods that are used to enhance heat transfer. Swirl fluid flow inside the tube and related heat transfer characteristics are very complex. ANSYS FLUENT (V 16.1) and ASPEN industrial program are used in analyzing this technique for enhancement heat transfer. A circular plain tube has length L=8534mm and 17 mm inner diameter with a twisted tape of twist ratio of y = (H/D) = (150/17) =8.8 along the plain tube were considered for this study. Eight Reynolds numbers (Re) of 784, 1000, 2000, 3000, 4000, 5000, 6000 and 7000 are used to analyze the response of thermal performance. Crude oil API 28 exit temperature, film heat transfer coefficient, Nus
... Show MoreWeb testing is very important method for users and developers because it gives the ability to detect errors in applications and check their quality to perform services to users performance abilities, user interface, security and other different types of web testing that may occur in web application. This paper focuses on a major branch of the performance testing, which is called the load testing. Load testing depends on an important elements called request time and response time. From these elements, it can be decided if the performance time of a web application is good or not. In the experimental results, the load testing applied on the website (http://ihcoedu.uobaghdad.edu.iq) the main home page and all the science departments pages. In t
... Show MoreThe aim of the research is to reveal the reality of teacher performance evaluation in the Sultanate of Oman in light of some global models. The study followed a qualitative descriptive research design. Seven forms of teacher formative and summative assessments were analyzed. Besides, an analytical template was developed, consisting of six areas related to the teaching performance of teachers. These included: lesson planning and preparation, learning environment, education, professional development, student academic, and community and parental partnership. The study reached a number of results; the most notable is the lack of change of forms for more than a decade despite the rapid development of the educational system in the sultanate in
... Show MoreIncident laser power and concentration effects on fluorescence emission from DCM dye in PMMA polymer have been investigated. Different concentrations of the dye were used. It was found that the fluorescence intensity increased with increasing of the concentration of the dye, with a red shift. In addition, it was found that the fluorescence intensity increased with the increase of the incident laser power I0.