Background: Hypothyroidism is the most prevalent thyroid disorders worldwide. Hypothyroidism manifestations are wide spectrum, affecting various systems in human body including the nervous system. Hypothyroidism can cause neuropsychiatric symptoms such as anxiety, depression and diminishing in attention, memory and executive function. Aim: to investigate the level of anxiety and depression in patients with hypothyroidism receiving levothyroxine treatment. Method: a cross-sectional study was conducted at Baghdad Center for Nuclear Medicine and Radiation Therapy from March to June 2022. The study population included patients of both genders, aged 18-65 years, diagnosed with hypothyroidism, were receiving levothyroxine treatment and have achieved euthyroid state for at least 2 months prior to their enrolment in the study. Based on levothyroxine dose, the enrolled patients were divided into two groups: low dose group < 1.7 µg/kg/day and high dose group ≥ 1.7 µg/kg. Hospital Anxiety and Depression Scale (HADS) was used for the evaluation of anxiety and depression. Result: The mean age of the participants was 40.35 ± 9.5 years with mean body mass index of 30.61 ± 5.72 kg/m2. The mean scores of anxiety and depression for the total sample are 8.72 ±3.46 and 7.80 ±2.83; respectively, there was statistically non-significant difference for anxiety and depression scores between the low dose group and the high dose group. Conclusion: the presence of anxiety and depression symptoms although the patients were in euthyroid state. However, socio-demographic and clinical characteristics did not significantly influence the scores of anxiety and depression.
This research investigates manganese (Mn) extraction from Electric Arc Furnace Steel Slag (EAFS) by using the Liquid-liquid extraction (LLE) method. The chemical analysis was done on the slag using X-ray fluorescence, X-ray diffraction, and atomic absorption spectroscopy. This work consisted of two parts: the first was an extensive study of the effect of variables that can affect the leaching process rate for Mn element from slag (reaction time, nitric acid concentration, solid to liquid ratio, and stirring speed), and the second part evaluates the extraction of Mn element from leached solution. The results showed the possibility of leaching 83.5 % of Mn element from the slag at a temperature of 25°C, nitric acid co
... Show More
Multipoint forming process is an engineering concept which means that the working surface of the punch and die is produced as hemispherical ends of individual active elements (called pins), where each pin can be independently, vertically displaced using a geometrically reconfigurable die. Several different products can be made without changing tools saved precious production time. Also, the manufacturing of very expensive rigid dies is reduced, and a lot of expenses are saved. But the most important aspects of using such types of equipment are the flexibility of the tooling. This paper presents an experimental investigation of the effect of three main parameters which are blank holder, rubber thickness and forming speed th
... Show MoreThe objective of this paper is to improve the general quality of infrared images by proposes an algorithm relying upon strategy for infrared images (IR) enhancement. This algorithm was based on two methods: adaptive histogram equalization (AHE) and Contrast Limited Adaptive Histogram Equalization (CLAHE). The contribution of this paper is on how well contrast enhancement improvement procedures proposed for infrared images, and to propose a strategy that may be most appropriate for consolidation into commercial infrared imaging applications.
The database for this paper consists of night vision infrared images were taken by Zenmuse camera (FLIR Systems, Inc) attached on MATRIC100 drone in Karbala city. The experimental tests showed sign
A simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration
... Show MoreThirteen isolates were collected from various clinical sources during the periodfrom 22/10/2017 to 22/12/2017. All the isolates were diagnosed based on the microscopic and biochemical propertiesby Vitek-2 Compact system. All isolates formed biofilm 100%, with 30% of isolatesbiofilm produced strongly and 70% on medium. The results of the present study have shown the presence of Curli fimbriae genes in E. cloacae bacteria from cases of urinary tract infections, infected patient with blood bacteremia and inflammation of wounds. Curli fimbriae is considered to be an important factor in the virulence of E.cloacae bacteria, which plays an important role in adhering and combining cells on solid surfaces to form the biofilmand helps in the adhesion
... Show MoreProteus mirabilis isolates have been intensively researched for their capacity to cause urinary tract infections (UTIs) and their swarming motility, although little is known about this phenomenon. Probiotic Lactobacillus species, which are beneficial bacteria, are being studied worldwide as therapeutic and preventative agents against bacterial infections. This study investigated Lactobacillus supernatants as a potential new treatment against Proteus mirabilis. In addition to testing their antimicrobial and anti-swarming activities, the research also aimed to understand the genetic mechanisms behind the observed phenotypic changes. Methods. A total of 150 urine specimens were collected from UTI patients at various hospitals in Baghdad. Dire
... Show MorePharmaceuticals have been widely remaining contaminants in wastewater, and diclofenac is the most common pharmaceutical pollutant. Therefore, the removal of diclofenac from aqueous solutions using activated carbon produced by pyrocarbonic acid and microwaves was investigated in this research. Apricot seed powder and pyrophosphoric acid (45 wt%) were selected as raw material and activator respectively, and microwave irradiation technique was used to prepare the activated carbon. The raw material was impregnated in pyrophosphoric acid at 80◦C with an impregnation ratio of 1: 3 (apricot seeds to phosphoric acid), the impregnation time was 4 h, whereas the power of the microwave was 700 watts with a radiation time of 20 min. A series o
... Show MoreSpectrophotometric method was developed for the determination of copper(II) ion. Synthesized (2,2[O-Tolidine-4,4-bis azo]bis[4,5-diphenyl imidazole]) (MBBAI) was used as chromogenic reagent at pH=5. Various factors affecting complex formation, such as, pH effect, reagent concentration, time effect and temperature effect, have been considered and studied. Under optimum conditions concentration ranged from (5.00-80.00) µg/mL of copper(II) obeyed Beer`s Low. Maximum absorption of the complex was 409nm with molar absorpitivity 0.127x104 L mol-1 cm-1. Limit of detection(LOD) and Limit of quantification were 1.924 and 6.42 μg/mL, respectively.
... Show MoreA newly developed analytical method was conducted for the determination of Ketotifen fumarate (KTF) in pharmaceuticals drugs via quenching of continuous fluorescence of 9(10H)-Acridone (ACD). The method was applied using flow injection system of a new homemade ISNAG fluorimeter with fluorescence measurements at ± 90◦ via 2×4 solar cell. The calibration graph was linear in the range of 1-45 mmol/L, with correlation coefficient r = 0.9762 and the limit of detection 29.785 µg/sample from the stepwise dilution for the minimum concentration in the linear dynamic ranged of the calibration graph. The method was successfully applied to the determination of Ketotifen fumarate in two different pharma
... Show More