Background: Hybrid diabetes (or double diabetes, DD) occur when the patient which exhibits characteristics that combine type 1 diabetes (T1DM) and type 2 diabetes (T2DM). Formerly epidemiological studies found that quarter of people with T1D also had the metabolic syndrome. Subfatin, Also called cometin, it is a small (~27kDa) cytokine secreted by protein encoded by a gene called METRNL (simeler of meteorin). is much expressed in skin in the mucosal tissues and activated macrophages. Subfatin has also been described as a hormone that effected in some diseases such as metabolic diseases (including dyslipidemia), type 2 diabetes and obesity. Objectives: The current study objective is evaluating the subfatin in the blood serum of double diabetes patients to find predictive significance of diagnosis for this disease. Subjects and methods: Eighty individuals were studied , divided them into two groups . Forty patients with double diabetes represented the first group (G1), and the second group (G2), which represented the control group, consisted of (40) individuals, and the range ages of the study were (18-60)years. Whole blood was used to determine HbA1c. Samples were centrifuged, and the obtained serum was used to evaluate other biochemical markers. The technique used to determine the level of subfatin in the blood was a quantitative sandwich enzyme-linked immunosorbent assay (ELISA). Results: A significant increase shown by this study in the serum levels of subfatin in (DD) patients (n = 40) compared with control subjects (n = 40) (p value < 0.05). The ROC curves analysis for serum subfatin level when used as test for diagnosis subjects into of double diabetes cases (G1) and control group (G2), showed the AUC ( area under curve) for serum of subfatin was (1.000) have interval of confidence (95% ) and both lower and upper bound was (1.000). Conclusions: serum subfatin level could be a used as a novel biomarker of double diabetes (DD) and may contribute to the early diagnosis of diabetes.
A Schiff base ligand (L) was synthesized via condensation of
Environmentally friendly copper oxide nanoparticles (CuO NPs) were prepared with a green synthesis route via Anchusa strigosa L. Flowers extract. These nanoparticles were further characterized by FTIR, XRD and SEM techniques. Removing of Gongo red from water was applied successfully by using synthesized CuO NPs which used as an adsorbent material. It was validated that the CuO NPs eliminate Congo red by means of adsorption, and the best efficiency of adsorption was gained at pH (3). The maximum adsorption capacity of CuO NPs for Congo red was observed at (35) mg/g. The equilibrium information for adsorption have been outfitted to the Langmuir, Freundlich, Temkin and Halsey adsorption isot
... Show MoreThe current study performed in order to detect and quantify epicatechin in two tea samples of Camellia sinensis (black and green tea) by thin layer chromatography (TLC) and high performance liquid chromatography (HPLC). Extraction of epicatechin from black and green tea was done by using two different methods: maceration (cold extraction method) and decoction (hot extraction method). Qualitative and quantitative determinations of epicatechin in two tea samples were investigated. Epicatechin identification was made by utilizing preliminary chemical tests and TLC. This identification was also boosted by HPLC and then quantified epicatechin in all ethyl acetate fractions of two tea samples. This research revealed the existence of epica
... Show MoreA new Ni(II) nanostructured chelating system (DHN) was introduced for selective optical heavy-metal ion sensing in an aqueous medium. The cooperative chelating system comprising 8-hydroxyquinoline (8-HQ) and dimethylglyoxime (DMG) has been developed for the first time in association with fibre optic sensing for selective optical heavy-metal ion sensing in an aqueous medium. The Ni(II) nanocompound fluoresces upon 578 nm excitation, showing a highly sensitive optical response with a linear calibration curve in the range 0–100 ng/mL. The regression equation of the calibration curve is y = 0.0035x + 0.9990, which indicates very good linearity, implying R2 = 0.999 with high sensitivity (calibration slope of 0.0035) and low baseline noise (bla
... Show MoreThis study examined the adsorption behavior of anionic dye (orange G) from aqueous solution onto the raw and activated a mixture of illite, kaolinite and chlorite clays from area of Zorbatiya (east of Iraq).The chemical treatment involved alkali and acid activation. The alkali activation obtained by treated the raw clay (RC) with 5M NaOH (ACSO) and the acid activation founded by treated it with 0.25M HCl (ACH) and 0.25M (ACS). The thermal treatment carried out by calcination the produce activated clay at 750oC for acid activation and 105oC for alkali activation. Batch
... Show More