Background: This study aimed to apply a high-power pulsed alexandrite laser in vitro, the researchers tested different exposure periods, pulse lengths, and laser fluencies to see which dosage was most successful against S. aureus bacteria, which had developed resistance to many antibiotics. Method: Three bacteria samples were exposed to laser beams for 30 seconds with a 5ms pulse duration and a laser fluency of 5J/cm2. The process was repeated with laser fluencies of 10, 15, and 20. Results: The study was carried out by using different doses of Alexandrite laser. Results: There are significant differences (p = 0.05) in the mean number of bacteria colonies exposed for 30 and 60 seconds at any laser fluencies utilized in the present investigation. Except for the 15 J.cm-2 laser fluency; there was a statistically significant difference (p < 0.001) between 60 sec and 90-sec exposure durations. Conclusion: In conclusion, the exposure periods, pulse durations, and laser fluencies of pulsed alexandrite laser were found to have an influence on the mean colony count of S aureus bacteria and to establish the effective dose.
both strongly associated with vascular and metabolic complications. Endothelin-1 is a potent vasoconstrictor that plays a key role in vascular tone regulation and endothelial function. Objective: To evaluate serum Endothelin-1 levels, lipid profile parameters (total cholesterol, LDL-C, VLDL-C, HDL-C, triglycerides), and HbA1c in patients with type 2 diabetes and essential hypertension compared with healthy controls, in order to assess their association with vascular injury and metabolic risk. Methods: A case-control study was conducted in the Department of Biochemistry, College of Medicine, University of Baghdad. Between November 2024 and February 2025, a sample of patients were recruited from Baghdad Teaching Hospital and Ibn Al-Bi
... Show MoreIn this study, cadmium oxide (CdO) was deposited on glass bases by thermal chemical spraying technique at three concentrations (0.05, 0.1, 0.15) M and then was irradiated by CO2 laser with 10.6 μm wave length and 1W power. The results of the atomic force microscope AFM test showed that the surfaces of these CdO thin films were homogenous and that the laser irradiated effect resulted in decreasing the roughness of the surface as well as the heights of the granular peaks, indicating a greater uniformity and homogeneity of the surfaces. The optical properties were studied to determine laser effect. The results of optical tests of these thin films showed that the photoluminescence spectra and absorption s
... Show MoreEffect of the thermal annealing at 400oC for 2 hours and Argon laser radiation for half hour on the optical properties of AgAlS2 thin films, prepared on glass slides by chemical spray pyrolysis at 360oC with (0.18±0.05) μm thickness .The optical characteristics of the prepared thin films have been investigated by UV/Vis spectrophotometer in the wavelength range (300 – 1100)nm .The films have a direct allow electronic transition with optical energy (Eg) values decreased from (2.25) eV for untreated thin films to (2.10) eV for the annealed films and to (2.00) eV for the radiated films. The maximum value of the refractive index (n) for all thin films are given about (2.6). Also the extinction coefficient (K) and the real and imaginary d
... Show MoreSamples of Hg0.15Ag0.85Ba2Ca2Cu3-xAgx O6+δ with x =0.0, 0.05, 0.1 and 0.15 were prepared using the standard solid-state reaction technique. The study used X-ray diffraction XRD analysis and a scanning electron microscope to examine how the partial substitution of silver in superconductors, along with 90 seconds of laser irradiation, affected their structures. The XRD analysis exposed a tetragonal structure for all samples, increasing the lattice constant a by the increasing of x compared to the sample with no silver substance. Also, it was found that changing the concentrations of silver in the samples leads to a change in density ρm and HTP (high-temperature phase). After exposure to laser radiation, there were variances in latti
... Show MoreIn this study, Laser Shock Peening (LSP) effect on the polymeric composite materials has been investigated experimentally. Polymeric composite materials are widely used because they are easy to fabricate and have many attractive features. Unsaturated polyester resin as a matrix was selected and Aluminum powder with micro particles as a reinforcement material was used with different volume fraction (2.5%, 5% and 7.5%). Hand lay-up process was used for preparation the composites. Fatigue test with constant amplitude with stress ratio (R =-1) was carried out before and after LSP process with two levels of energy (1Joule and 2Joule). The result showed an increase in the endurance strength of 25.448% at 7.5% volume fraction when peened is 1J
... Show MoreTerrestrial Laser Scanning (TLS) can be used to detect damage and analyze volumetric changes in large structural test specimens. Compared to traditional imaging and surface analysis methods, the primary reason for using 3D scanning is the difficulty of attaching targets to towers of varying heights, as well as the fact that some towers are covered with insulating materials that obscure key landmarks. In addition, the large number of incoming and outgoing pipes and stairs attached to the towers further complicates traditional assessment methods. This research focuses on assessing the damage to the three refining towers at the Baiji Refinery facility. Scanning was performed using a 3D laser scanner with HDR color imaging, capturing da
... Show MoreThe objective of the research is to shed light on the nature of the impact of the activities of the national strategy for poverty alleviation in achieving the goals of sustainable development, and the research problem was represented by Is there an effect of the activities of the national strategy for poverty reduction in achieving the goals of sustainable development? and represents the field of research in the Ministry of Labor and Social Affairs For the years (2012-2016) and the results of the sustainable development goals indicators for the years (2012-2016), the ready-made statistical program (SPSS ver.10) was used to calculate the percentages, multiple linear regression equation, the F test and the R2 coefficient, and the research
... Show MoreBackground: planter fasciitis is a common condition
seen in adults and sport men, it is characterized by dull
pain in the heel, especially when getting up and
standing on the foot in the morning or after sitting for a
long time.
Recently low level laser therapy is used as a method of
treatment.
Objective: to evaluate the benefit of laser therapy in
treatment of planter fasciitis.
Methods: Out of twenty five patients with planter
fasciitis exposed to laser therapy. Laser used is (diode
type) given in two cessions per week for four weeks,
time for each cession is about (12 minutes).
Results: complete recovery seen in (32%) of patients,
moderate improvement in (16%), mild improvement in
(24%), no
Background: Atrophic postoperative and traumatic scarring are common cosmetic problems for patients. Combining CO2 laser ablation with a fractional photothermolysis system in a treatment known as ablative fractional resurfacing fulfilling the new demands for a lesser risk of side effects and minimal or no downtime.Objective: To assess the safety and efficacy of ablation fractional CO2 laser treatments for surgical scarring .methods: Twenty one patient ( 14 women, and 7 men ) with various skin types , I to IV , aged 3 to 48 years , presents with 24 scars between June and December 2012 , four patients excluded from study because they are not continued in follow up , the remaining 17 patient completed all 3 treatments & 6 months follow
... Show MoreThere are many causes for epistaxis but it is mainly idiopathic in type. In Management of epistaxis there are different modality either medical or cautery(chemical or galvanic) recently laser is used in management of epistaxis. The type of laser used in current study was 810 nm diode laser. The aim of the study is to evaluate its efficiency in control of active and non active idiopathic epistaxis; The design of the study is interventional therapeutic trial. The study was performed from December 2011 to December 2012 in Al Yarmouk teaching hospital at otorhinolaryngology department. In current study the diode laser is used in different power with same exposure time in all application; The power density is measured and choose the best one
... Show More