The Humidification-Dehumidification (HDH) desalination technique offers a viable solution for providing freshwater to populations in water-scarce, remote areas. This study experimentally investigates a novel humidifying method by cross airflow over water-wetted pottery tubes, which function as a humidifier, incorporating a thermoelectric cooler to condense water vapor for freshwater production. To optimize freshwater production and thermal efficiency, meticulous design of these components and appropriate operational parameters are selected. Experiments were performed in three environments with differing temperatures and relative humidity levels, while air velocity varied from 1.02 to 1.89 m/s, and thermoelectric cooler voltage ranged from 6 to 12 V. These measures include GOR, COP, fresh water production, and dehumidifier efficiency. Air, saline water, and thermoelectric cooler voltage volume flow rates greatly affected system performance, according to the findings. The obtained optimal freshwater yield, COP, humidification efficiency, evaporation efficiency, and GOR were 1.7 L/hr, 4.3, 71 %, 65 %, and 4.6, respectively. Higher water productivity is indicated for low saline water flowrate supplied. Results show 71 % efficiency of the pottery tube humidifier for air speed lower than 1.02 m/s. Increasing the air flow rate from 38.88 m3/hr to 72 m3/hr decreases the system’s freshwater yield from 1.7 L/hr to 0.7 L/hr. A 55.8 % reduction in COP is found as the thermoelectric voltage increases from 6 to 12 volts for the same air flow rate (38 m3/hr). The results indicate that pottery tubes and air velocity significantly influence freshwater yield and energy efficiency, thereby promoting cost-effective and sustainable atmospheric water harvesting.
Objectives: To review the failure rates of molar tubes and the effect of molar tube base design, adhesive type, and bonding technique on the failure rates of molar tubes. Data: The revolution of molar bonding greatly impacted fixed orthodontic appliance treatment by reducing chair-side time and improving patient comfort. Even with the many advantages of molar bonding, clinicians sometimes hesitate to use molar tubes due to their failure rates. Sources: Internet sources, such as Pubmed and Google Scholar. Study selection: studies testing the bond failure rate of molar tubes. Conclusions: The failure rate of the molar tubes can be reduced and the bond strength of the molar tubes can be improved by changing the design of the molar tube base
... Show MoreThe aerodynamic characteristics of the forward swept wing aircraft have been studied theoretically and experimentally. Low order panel method with the Dirichlet boundary condition have been used to solve the case of the steady, inviscid and compressible flow. Experimentally, a model was manufactured from wood to carry out the tests. The primary objective of the experimental work was the measurements of the wake dimensions and orientation, velocity defect along the wake and the wake thickness. A blower type low speed (open jet) wind tunnel was used in the experimental work. The mean velocity at the test section was (9.3 m/s) and the Reynolds number based on the mean aerodynamic chord and the mean velocity was (0.46x105). The measurements sho
... Show MoreThe aim of this research is to estimate the area unit function of productivity for the potato crop in Anbar province for the autumn season (2008 / 2009) Anbar province has been chosen as an applied model for the study due to its well known in cultivating potato crop , and the data were collected through a random sample about (10%) from the study society with a (150) farmers, The results indicated that the double logarithmic formula was the best representative of the relationship between crop productivity and independent variables (quantity of potato tubers , quantity of herbicides stuffs, quantity of fertilizer , hours of mechanical labour
... Show MoreHeat transfer process and fluid flow in a solar chimney used for natural ventilation are investigated numerically and experimentally her in. Solar chimney was designed, manufactured and tested by selecting different positions of air entrance namely: bottom entrance, side entrance, and both side and bottom entrances. The effect of integrating the chimney with paraffin (phase change material) on its thermal behavior has been also investigated. CFD analysis based on finite volume method is used to predict the thermal performance, and fluid flow in two-dimensional solar chimney under unsteady state condition, to identify the effect of different parameters such as solar radiation, and inclination angle. Experimental results show that a solar chi
... Show MoreIn this paper, an experimental study was conducted to enhance the thermal performance of a double-pass solar air heater (SAH) using phase change material (PCM) for thermal storage at climatic conditions of Baghdad city - Iraq. The double-pass solar air heater integrated with thermal storage system was manufactured and tested to ensure that the air heating reserved after the absence of the sun. The rectangular cavity filled with paraffin wax was used as a latent heat storage and incorporated into the lower channel of solar air heater. Experiments were carried out to evaluate the charging and discharging characteristics of two similar designed solar air collectors with and without using phase change material at a constant
... Show MoreThe coefficient of performance of a window type Air-Conditioner system can be improved if a reduction in the work of compressor can be achieved by a suitable technique. The present study investigates the effect of dispersing a low concentration of TiO2 nanoparticles in the mineral oil based lubricant, as well as on the overall performance of a window type Air-Conditioner system using R22 as the working fluid. An enhancement in the COP of the refrigeration system has been observed and the existence of an optimum volume fraction noticed, with low concentrations of nanoparticles suspended in the mineral oil. Results showed that the average compressor work reduced by 13.3%, which ultimately resulted in an increase of 11.99% in the COP due to
... Show MoreThe skirt foundation is one of the powerful types of foundations to resist the lateral loads produced from natural forces, such as earthquakes and wind action, or from the type of structures, such as oil platforms and offshore wind turbines.
This research experimentally investigated the response of skirted footing resting on sandy soil of different states to lateral applications of loads on a small-scale physical model manufactured for this purpose. The parameters studied are the dista
In this work Laser wireless video communication system using intensity modualtion direct
detection IM/DD over a 1 km range between transmitter and receiver is experimentally investigated and
demonstrated. Beam expander and beam collimeter were implemented to collimete laser beam at the
transmitter and focus this beam at the receiver respectively. The results show that IM/DD communication
sysatem using laser diode is quite attractive for transmitting video signal. In this work signal to noise
ratio (S/N) higher than 20 dB is achieved in this work.
In the present work, experimental tests was done to explain the effect of insulation and water level on the yield output. Linear basin, single slope solar still used to do this purpose. The test was done from May to August 2017 in Mosul City-Iraq (Latitude: Longitude: Elevation: 200 m, and South-East face). Experimental results showed that the yield output of the still increased by 20.785% and 19.864% in case of using thermal insulation at 4cm and 5cm respectively, also the yield output decrease by 15.134% as the water level increase from 4 to 5cm, with the presence of insulation and 14.147% without it. It has been conclude that the insulation and water level play important role in the process of passive
... Show MoreA new bio-electrochemical system was proposed for simultaneous removal of organic matters and salinity from actual domestic wastewater and synthetically prepared saline water, respectively. The performance of a three-chambered microbial osmotic fuel cell (MOFC) provided with forward osmosis (FO) membrane and cation exchange membrane (CEM) was evaluated with respect to the chemical oxygen demand (COD) removal from wastewater, electricity generation, and desalination of saline water. The MOFC wasinoculated with activated sludge and fueled with actual domestic wastewater. Results revealed that maximum removal efficiency of COD from wastewater, TDS removal efficiency from saline water, power density, and current density were
... Show More