The Humidification-Dehumidification (HDH) desalination technique offers a viable solution for providing freshwater to populations in water-scarce, remote areas. This study experimentally investigates a novel humidifying method by cross airflow over water-wetted pottery tubes, which function as a humidifier, incorporating a thermoelectric cooler to condense water vapor for freshwater production. To optimize freshwater production and thermal efficiency, meticulous design of these components and appropriate operational parameters are selected. Experiments were performed in three environments with differing temperatures and relative humidity levels, while air velocity varied from 1.02 to 1.89 m/s, and thermoelectric cooler voltage ranged from 6 to 12 V. These measures include GOR, COP, fresh water production, and dehumidifier efficiency. Air, saline water, and thermoelectric cooler voltage volume flow rates greatly affected system performance, according to the findings. The obtained optimal freshwater yield, COP, humidification efficiency, evaporation efficiency, and GOR were 1.7 L/hr, 4.3, 71 %, 65 %, and 4.6, respectively. Higher water productivity is indicated for low saline water flowrate supplied. Results show 71 % efficiency of the pottery tube humidifier for air speed lower than 1.02 m/s. Increasing the air flow rate from 38.88 m3/hr to 72 m3/hr decreases the system’s freshwater yield from 1.7 L/hr to 0.7 L/hr. A 55.8 % reduction in COP is found as the thermoelectric voltage increases from 6 to 12 volts for the same air flow rate (38 m3/hr). The results indicate that pottery tubes and air velocity significantly influence freshwater yield and energy efficiency, thereby promoting cost-effective and sustainable atmospheric water harvesting.
Abstract
The effect of physical and mental health on the feelings of personal welfare are known as health-related quality of life. Infection with hepatitis B virus is a major global health problem. Health-related quality of life was emerged as an important consideration in the care of patients with chronic hepatitis B infection. The aim of the current study was to measure health-related quality of life among a sample of chronic hepatitis B patients in AL-Najaf city/Iraq. The current study was cross-sectional study carried out on (104) already diagnosed chronic viral hepatitis B patients who attended the Gastroenterology and Hepatology Center/Al-Sader Medical City/Najaf during November 2018 to May
... Show MorePresent study was conducted in order to assess Slabiaat water quality by measuring some physical and chemical factors of river water, the study included a choice of three stations along of Slabiaat River in Samawa city, water samples collected a monthly during the period from September 2013 August 2014. The study involved measuring the Air & water temperatures, pH, Electrical conductivity, Total dissolved solids, Dissolved oxygen, Total hardness, calcium hardness, magnesium, turbidity, and some types of bacteria in River water. The study results showed that the values of air & water temperatures have ranged between (20.1-36.6)?C , (10-21.8) in Slabiaat River, respectively . pH values ranged between (6.6-8.7). Electrical conductivity in
... Show MoreA solar updraft tower power plant (solar tower) is a solar thermal power plant that utilizes a combination of solar
air collector and central updraft tube to generate an induced convective flow which drives pressure staged turbines to generate electricity.
This paper presents practical results of a prototype of a solar chimney with thermal mass, where the glass surface is replaced by transparence plastic cover. The study focused on chimney's basements kind effect on collected air temperatures. Three basements were used: concrete, black concrete and black pebbles basements. The study was conducted in Baghdad from August to November 2009.
The results show that the best chimney efficiency attaine
... Show MoreThe distribution of chilled water flow rate in terminal unit is a major factor used to evaluate the performance of central air conditioning unit. In this work, a theoretical chilled water distribution in the terminal units has been studied to predict the optimum heat performance of terminal unit. The central Air-conditioning unit model consists of cooling/ heating coil (three units), chilled water source (chiller), three-way and two-way valve with bypass, piping network, and pump. The term of optimization in terminal unit ingredient has two categories, the first is the uniform of the water flow rate representing in statically permanents standard deviation (minimum value) and the second category is the maximum heat transfer rate fro
... Show MoreAlmost all thermal systems utilize some type of heat exchanger. In a lot of cases, evaporators are important for systems like organic Rankine cycle systems. Evaporators give a share in a large portion of the capital cost, and their cost is significantly attached to their size or transfer area. Open-cell metal foams with high porosity are taken into consideration to enhance thermal performance without increase the size of heat exchangers. Numerous researchers have tried to find a representation of the temperature distribution closer to reality due to the different properties between the liquid and solid phases. Evaporation heat transfer in an annular pipe of double pipe heat exchanger (DPHEX) filled with cooper foam is investigated numerical
... Show MoreA solar cell was manufactured from local materials and was dyed using dyes extracted from different organic plants. The solar cell glass slides were coated with a nano-porous layer of Titanium Oxide and infused with two types of acids, Nitric acid and Acetic acid. The organic dyes were extracted from Pomegranate, Hibiscus, Blackberry and Blue Flowers. They were then tested and a comparison was made for the amount of voltage they generate when exposed to sunlight. Hibiscus sabdariffa extract had the best performance parameters; also Different plants give different levels of voltage.
This work provides an analysis of the thermal flow and behavior of the (load-free) refrigerator compartment. The main goal was to compare the thermal behavior inside the refrigerator cavity to the freezer door (home refrigerator) effect and install a fan on the freezer door while neglecting the heat transmitted by thermal radiation. Moreover, the velocity distribution, temperature, and velocity path lines are theoretically studied. This was observed without affecting the shelves inside the cabinet and the egg and butter places on the refrigerator door as they were removed and the aluminum door replaced with a glass door. This study aims to expand our knowledge about the temperature and flow fields of this refrigerator mo
... Show MoreDust and bird residue are problems impeding the operation of solar street lighting systems, especially in semi-desert areas, such as Iraq. The system in this paper was designed and developed locally using simple and inexpensive materials. The system runs automatically. It Connects to solar panels used in solar street lighting, and gets the required electricity from the same solar system. Solar panels are washed with dripping water in less than half a minute by this system. The cleaning period can also be controlled. It can also control, sensing the amount of dust the system operates. The impact of different types of falling dust on panels has also been studied. This was collected from different winds and studied their impact o
... Show MoreIn 2010, the tomato leaf miner Tuta absoluta (Meyrick, 1917) was reported for the first time in Iraq. The larvae can feed on all parts of tomato plants and can damage all the growth stages. The main host plant is tomato, Lycopersicon esculentum, but it can also attack other plants in Solanaceae family. In this study it was found attacking alfalfa plants, Medicago sativa in Baghdad Province. This finding reveals that alfalfa also serves as a host plant for T. absoluta in Iraq.