Mathematical Modeling and Kinetics of Removing Metal Ions from Industrial Wastewater
...Show More Authors

The study's objective is to produce Nano Graphene Oxide (GO) before using it for batch adsorption to remove heavy metals (Cadmium Cd+2, Nickel Ni+2, and Vanadium V+5) ions from industrial wastewater. The temperature effect (20-50) °C and initial concentration effect (100-800) mg L-1 on the adsorption process were studied. A simulation aqueous solution of the ions was used to identify the adsorption isotherms, and after the experimental data was collected, the sorption process was studied kinetically and thermodynamically. The Langmuir, Freundlich, and Temkin isotherm models were used to fit the data. The results showed that Cd, Ni, and V ions on the GO adsorbing surface matched the Langmuir model with correlation coefficients (R2) of 0.999. Kinetic models studied showed that a pseudo-second-order model was followed and thermodynamically, the process was exothermic due to ∆H negative, the reduction in randomness because of negative ∆S. additionally, spontaneous adsorption of metal ions was ∆G negative values influenced.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jan 21 2021
Journal Name
Iop Conf. Series: Materials Science And Engineering
Synthesis, spectroscopic study, biological activity and dyeing application of curcumin - Schiff base with various metal ions complexes
...Show More Authors

A tetradentate (N2O2) Schiff base (H2Ldfm) was successfully synthesized via condensation of curcumin / diferuloylmethane (dfm) and L-leucine amino acid (HL). There were three different methods that used for synthesizing H2Ldfm; (refluxing, grading, and fusion). Ten different metal complexes were also successfully synthesized by combination of the Schiff base (H2Ldfm) and 1,10-phenanthroline (phen) ligand to form a hexadentate (N4O2) mixed ligands (Ldfm , phen) with ten different metal salts (M) where{ M= Al(III), Mn(II), Fe(III), Co(II), Ni(II), Cu(II), Ag(I), Cd(II), Hg(II), and Pb(II)}. The molar ratio of reactants was (1:1:1) (M: H2Ldfm : phen). The new Schiff base and its new complexes were characterized by different physicochemical tec

... Show More
Preview PDF
Publication Date
Sat Jan 07 2023
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Cr (III), Fe (III), Co (II) and Cu(II)Metal ions Complexes with Azo Compound Derived from 2-hydroxy Quinoline Synthesis, Characterization, Thermal Study and Antioxidant Activity
...Show More Authors

Azo-ligand-(HL) ([4- ((2-hydroxyquinolin-3-yl) diazenyl) -N- (5-methylisoxazol-3yl) benzenesulfonamide]), (2- hydroxy quinolin derivative),reacts with the next metal ions (Cr (III), Fe (III),Co (II) and Cu(II)) forming stable complexes with unique geometries such as(tetrahedral for bothCo (II) and Cu (II), octahedral for both Cr (III) and Fe (III)). The creation of such complexes was detected by employing spectroscopic means involving ultraviolet-visible which proved the obtained geometries, Fourier transfer proved the involvement of coordinated water molecule in all complexes besides the pyrolysis (TGA & DSC) studies proved the coordination of water residues with metal ions inside the coordination sphere as well as chlorine atoms. Moreover

... Show More
Publication Date
Thu Jul 31 2025
Journal Name
Indonesian Journal Of Chemistry
Evaluation of the Antioxidant and Anticancer Effectiveness of Some New Metal Ions Complexes with Azo Dye: Synthesis and Characterization
...Show More Authors

This paper presents a new azo dye 3-[2-(1H-indol-2-yl)ethyldiazenyl]quinolin-2-ol] from the reaction of the diazonium salt derived from tryptamine and 2-hydroxyquinoline. Azo dye was used to prepare a series of complexes with the chlorides of Ni(II), Pt(IV), Pd(II), Cd(II), and Zn(II). Compounds were analyzed and characterized using elemental analysis, magnetic measurement, UV-vis, IR, MS, NMR, and conductivity. The findings demonstrated that the ligand acts as ionic in complex form, O-bidentate, supporting the proposed formula. The complexes generally exhibited tetrahedral and octahedral geometries, except the palladium complex, which adopted a square planar geometry. TGA was used to investigate the thermal characteristics of compo

... Show More
View Publication
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
International Journal Of Pharmaceutical Research
Synthesis, characterization and bioactivity study of mixed-lig and complexes with some metal ions for new dithiocarbamate,3-aminophenol
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sun May 23 2010
Journal Name
Ibn Al- Haitham J. Fo R Pure & Appl. Sc I
Synthesis, Spectroscopic and Dyeing Performance Studies of Some New Heterocyclic Azo Dyes and Their Complexes with Selected Metal Ions
...Show More Authors

Coupling reaction of m-and p- amino acetop henone and p-amino benzoic acid with (LHistidine) gave the new bidentate azo ligands (L1, L2 and L3). The prepared ligands were identified by FT-IR, UV-Vis, 1HNMR and GC- mass sp ectroscopic technique. Treatment of the prepared ligands with the following metal ions (CoII, NiII, CuII, ZnII, CdII and HgII) in aqueous ethanol with a 1:2 M:L ratio and at optimum pH, yielded a series of neutral complexes of the general formula [M (L)2 Cl2]. The prepared complexes were characterized by using flame atomic absorption, FT-IR, UV-Vis and 1HNMR spectroscopic methods as well as magnetic susceptibility and conductivity measurements. Chloride ion content was also evaluated by (Mohr method). The nature of the com

... Show More
Publication Date
Fri Jul 19 2024
Journal Name
Applied Science And Engineering Progress
Multicomponent Equilibrium Isotherms and Kinetics Study of Heavy Metals Removal from Aqueous Solutions Using Electrocoagulation Combined with Mordenite Zeolite and Ultrasonication
...Show More Authors

Combining different treatment strategies successively or simultaneously has become recommended to achieve high purification standards for the treated discharged water. The current work focused on combining electrocoagulation, ion-exchange, and ultrasonication treatment approaches for the simultaneous removal of copper, nickel, and zinc ions from water. The removal of the three studied ions was significantly enhanced by increasing the power density (4–10 mA/cm2) and NaCl salt concentration (0.5–1.5 g/L) at a natural solution pH. The simultaneous removal of these metal ions at 4 mA/cm2 and 1 g NaCl/L was highly improved by introducing 1 g/L of mordenite zeolite as an ion-exchanger. A remarkable removal of heavy metals was reported

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Fri Jul 19 2024
Journal Name
Applied Science And Engineering Progress
Multicomponent Equilibrium Isotherms and Kinetics Study of Heavy Metals Removal from Aqueous Solutions Using Electrocoagulation Combined with Mordenite Zeolite and Ultrasonication
...Show More Authors

Combining different treatment strategies successively or simultaneously has become recommended to achieve high purification standards for the treated discharged water. The current work focused on combining electrocoagulation, ion-exchange, and ultrasonication treatment approaches for the simultaneous removal of copper, nickel, and zinc ions from water. The removal of the three studied ions was significantly enhanced by increasing the power density (4–10 mA/cm2) and NaCl salt concentration (0.5–1.5 g/L) at a natural solution pH. The simultaneous removal of these metal ions at 4 mA/cm2 and 1 g NaCl/L was highly improved by introducing 1 g/L of mordenite zeolite as an ion-exchanger. A remarkable removal of heavy metals was reported

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
REMOVAL OF COPPER ION FROM WASTEWATER BY FLOTATION
...Show More Authors

Several industrial wastewater streams may contain heavy metal ions, which must be effectively removal
before the discharge or reuse of treated waters could take place. In this paper, the removal of copper( II)
by foam flotation from dilute aqueous solutions was investigated at laboratory scale. The effects of
various parameters such as pH, collector and frother concentrations, initial copper concentration, air flow
rate, hole diameter of the gas distributor, and NaCl addition were tested in a bubble column of 6 cm inside
diameter and 120 cm height. Sodium dodecylsulfate (SDS) and Hexadecyl trimethyl ammonium bromide
(HTAB) were used as anionic and cationic surfactant, respectively. Ethanol was used as frothers and the

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Jun 03 2015
Journal Name
Baghdad
Synthesis, characterization and Antibacterial of 2, 3 Dihydrobenzo Thiazole -2- Carboxylic acid complexes with some selected Metal ions.
...Show More Authors

Publication Date
Fri Jan 01 2021
Journal Name
Desalination And Water Treatment
Microwave induced activated carbon for the removal of metal ions in fixed-bed column study: modelling and mechanisms
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref