Age and BMI may be used to diagnosis of thyroid autoimmune disease. One hundred Iraqi women with age ranged from 18 to 60 years participate in this research, 50 of them were hypothyroidism patients, 30 were hyperthyroidism patients and the other 20 were euthyroidism served as controls. Blood samples were collected from the studied subjects to determine thyroid profile [free triiodothyronine (FT3), free tetraiodothyronine (FT4) and thyroid stimulating hormone (TSH)], thyroid antibodies [anti-thyroid peroxidase (anti-TPO), anti-thyroglobulin (anti-Tg), and anti-thyroid stimulating hormone receptor (anti-TSHR)], and levels of vitamin D (vit D), calcium (Ca), and phosphorus (P) using different analysis techniques. When the effect of age on the studied parameters was investigated, the findings of hyperthyroidism revealed a significant (P<0.05) decrease in levels of FT4, anti-TPO, anti-TG, vit D, and Ca with increase of age. The findings of hypothyroidism revealed a significant (P<0.05) increase in levels of TSH, anti-TPO, and anti-TG with progress of age; while a significant (P<0.05) decrease was found in levels of anti-TSHR, vit D, and Ca with progress of age. The findings of euthyroidism revealed a significant (P<0.05) increase in levels of TSH and anti-TG with progress of age. Also, a high significant (P<0.01) increase was found in levels of anti-TPO and anti-TSHR with progress of age. While a significant (P<0.05) decrease was found in levels of vit D with progress of age. On the other hand, when the effect of BMI on the studied parameters was investigated, the results of hyperthyroidism revealed a high significant (P<0.01) decrease in level of TSH with increase of BMI value. Also, levels of anti-TSHR, Ca, and P decreased significantly (P<0.05) with increase of BMI value. In hypothyroidism, the results showed a high significant (P<0.01) increase in levels of TSH, anti-TPO, and anti-TG with increase of BMI value; while levels of anti-TSHR, Ca, and P decreased significantly (P<0.05) with increase of BMI value. Conclusion: Both of age and body mass index affect on levels of thyroid hormones and thyroid autoantibodied in patients with thyroid disorders (hyperthyroidism and hypothyroidism).
Hypoxic training, which in turn is one of the methods adopted in sports training methods, especially in activities that depend on the aerobic system in its performance, which includes training with a lack of oxygen by reducing its molecular pressure, since this method targets functional organs and works temporary responses during training and permanent responses After training as an adaptation to these devices as a result of training in this way, the study aimed to identify the effect of hypoxic exercises using the training mask and the extent of the change in some biochemical indicators, in addition to that to identify the effect of these exercises on the indicator of energy expenditure and )VMA) and the achievement of the effectiveness of
... Show MoreBackground: Although methotrexate (MTX) is a frequently used chemotherapy drug, its effectiveness is sometimes hampered by the drug's toxic consequences. Omega 7 is a monounsaturated fatty acid, with different anti-inflammatory, anti-diabetic anti-obesity applications, and its possible protective effects against MTX-induced blood toxicity were investigated in this study. Objective: Evaluation of possible protective effects of omega7 against MTX-induced blood toxicity. Methods: 30 mice were divided into five groups, the First group take liquid paraffin orallyfor 7 days for served as negative control and the second group take methotrexate (20mg/kg) intraperitoneallyto serve as a positive control,the third group takes omega 7 (100mg/kg
... Show MoreThe bubble columns are widely used as a two or three phase reactor in industrial chemical process such as absorption, biochemical reactions, coal liquefaction, etc. To design such a column, two main parameters should be taken in consideration, the gas hold-up (), and the liquid phase mass transfer coefficient KLa. The study includes the effect of gas velocity and the addition of alcohols on gas hold-up and mass transfer coefficient in bubble column with draught tube when the length of the column is 1.5m and the ratio of the draught tube diameter to the column diameter equals 0.5 and the air dispersion into the base of the draught tube using a multi hole tuyere is equivalent to a diameter of 0.15 mm and
... Show Morehe study aimed to purify of Leucine aminopeptidase (LAP) from sera of hyperthyroidism patients and its relation to some thyroid hormones (TSH, T 3 , T 4 ) of subclinical hyperthyroidism and hyperthyroidism patients with lipid peroxidation levels that may be play a role in this diseases. Specimens were collected during the time from Nov 2017 until Jan 2018 from Endocrine and Diabetes Center, blood samples were collected from fifty healthy control and one hundred patients, patients were divided into two groups consisted of (50) with hyperthyroidism and (50) with subclinical hyperthyroidism. The aged for all subjects ranged (15-60) years with body mass ranged ((25- 29) kg/m 2 . The purification is done by addition of ammonium sulfate, dial
... Show MoreBackground: Hemoglobin A1c (HbA1c) is a widely used test for glycemic control. It is done for chronic kidney disease (CKD) patients. Renal disease is accompanied by thyroid abnormalities, which affect HbA1c, especially in those taking erythropoiesis-stimulating agents (ESAs). We aimed to find the effect of thyroid dysfunction on HbA1c in hemodialysis patients taking ESAs and those who do not. Materials and Method: Fifty six patients were included in this study, which was done between September 2017 and June 2018, in Baghdad Teaching Hospital. Thyroid stimulating hormone, free T3, free T4 and HbA1c measurements were done. The patients were divided into 2 groups; those who took ESAs and those who did not, then they were subdivided into those
... Show MoreAbstract Background Hemoglobin A1c (HbA1c) is a widely used test for glycemic control. It is done for chronic kidney disease (CKD) patients. Renal disease is accompanied by thyroid abnormalities, which affect HbA1c, especially in those taking erythropoiesis-stimulating agents (ESAs). We aimed to find the effect of thyroid dysfunction on HbA1c in hemodialysis patients taking ESAs and those who do not. Materials and Method Fifty six patients were included in this study, which was done between September 2017 and June 2018, in Baghdad Teaching Hospital. Thyroid stimulating hormone, free T3, free T4 and HbA1c measurements were done. The patients were divided into 2 groups; those who took ESAs and those who did not, then they were subdivided into
... Show MoreThe effect of the aqueous extract of fig (Ficus carica) fruit was studied by using different concentrations of this fruit (15, 20 and 25 mg/kg of body weight) on some hematological parameters (hemoglobin concentration, packed cell volume, white blood cell count and platelets count) in female rabbits. Twenty female rabbits were randomly divided into four groups (five animals in each group). Three groups were dosed with the concentrations mentioned above, while the last was administered with distilled water and considered as control group. These animals were orally dosed by aqueous extract using a micropipette. The results showed that there was a significant (P<0.05) increase in hemoglobin concentration and packed cell volume means for all
... Show MoreObjective: To determine the correlation between the second derivative of digital pulse wave and the QT variability index. Method: The cross-sectional study was conducted from October 2021 to May 2022 at the Department of Physiology, College of Medicine, University of Mustansiriyah, Baghdad, Iraq, and comprised healthy women. Samples were raised by simple random technique. Digital pulse waves were captured using a fingertip pulse wave transducer. Lab Chart Pro version 7.2 was used to automatically detect and quantify the amplitude of A, B, C, D and E waves expressed by the second derivative. QT interval of each beat was recorded by electrocardiogram, and was calculated automatically via Lab chart Pro version 7.2 without averaging. D
... Show More