Preferred Language
Articles
/
qBbWfYwBVTCNdQwChPxL
COII, NIII AND CDII COMPLEXES DERIVED FROM MIXED AZO-LINKED SCHIFF-BASE LIGANDS: FORMATION, CHARACTERISATION, THERMAL ANALYSIS AND BIOLOGICAL STUDY
...Show More Authors

The study includes preparation and characterisation of mixed azo-linked Schiff-base ligands and their complexes. The starting material was isolated from the mixing of 2-amino pyridine diazonium salt with 2-amino-phenole and 4-amino-3- hydroxy-1-naphthalene sulfonic acid respectively in 1:1 mole ratio in water. In this work, the formation of azo-linked Schiffbase ligands are reported. Ligands of the azo-linked Schiff-base was achieved by the reaction of starting material with 4- (dimethylamino) benzaldehyde) (HL1 and HL2). The complexes were prepared by mixing the azo-linked Schiff-base ligands with the metal salts; CoII, NiII and CdII in a 1:1:1 mole ratio. Ligands and complexes were characterised by analytical and spectroscopic analyses including; microanalysis, chloride content, thermal analysis, magnetic susceptibility for complexes, conductance, FTIR, UV-Vis and 1H-NMR spectroscopy. Physico-chemical techniques indicated complexes demonstrated six coordinate structures in the solid and solution sate. Biological activity of the ligands and their metal complexes were screened for their antimicrobial activity against four bacterial species (Escherichia coli and Enterobacter (G-)), (Bacillus stubtilis and Staphylococcus aureus (G+)).

Publication Date
Mon Jun 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Relationships between the Physical and Chemical Properties of Narrow Fractions Distilled From Mixed Kirkuk and Sharki-Baghdad Crude Oils
...Show More Authors

Mixed Kirkuk and Sharki-Baghdad crude oils were distilled into narrow fractions. The range of these narrow fractions were 10oC, starting from IBP to 350oC. The total distillates from mixed Kirkuk and Sharki-Baghdad crude oils were 58.25 vol % and 44.65 vol %, respectively.The hydrocarbons compositions (paraffin, naphthene, aromatic) in light fractions starting from IBP to 250oC were determined by using PONA analysis method. The results show that the paraffin content decreases with increasing mid percent boiling point of the fraction, while the naphthene, and aromatic increase with the increase of mid percent boiling point of mixed Kirkuk and Sharki-Baghdad crude oils. Three groups of empirical equations were developed for the prediction

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 01 2009
Journal Name
Bulletin Of The Iraq Natural History Museum (p-issn: 1017-8678 , E-issn: 2311-9799)
MICROFACIES STUDY OF HADIENE FORMATION (NORTH IRAQ)
...Show More Authors

In the region of the north of Iraq using the method of analyzing thin section microfacies to 38 of rockyslices which were gathered from a place near Aqra city. These slides are divided into seven microfacies depending on lithologcal component and fossils.

1) Dolostone facies.

2)Recrystallized bioclastic wackestone facies.

3) Bioclastic packstone microfacies

4)Sucrosic dolomite facies.

 5) Bioclastic grainstone in microfacies.

 According to water energy, these facies were divided to three zone:

  1. a) Low energy environment.
  2. b) Transitional zone.
  3. c) High energy environment.

View Publication Preview PDF
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
THEORETICAL AND EXPERIMENTAL STUDY ON THERMAL PERFORMANCE OF CLOSED WET COOLING TOWER
...Show More Authors

Thermal performance of closed wet cooling tower has been investigated experimentally and theoretically
in this work. The theoretical model based on heat and mass transfer equations and heat and mass transfer balance equations which are established for steady state case. A new small indirect cooling tower was used for conducting experiments. The cooling capacity of cooling tower is 1 kW for an inlet water temperature of 38oC, a water mass velocity 2.3 kg/m2.s and an air wet bulb temperature of 26oC. This study investigates the relationship between saturation efficiency, cooling capacity and coefficient of performance of closed wet cooling tower versus different operating parameters such wet-bulb temperature, variable air-spray water fl

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Oct 01 2023
Journal Name
Baghdad Science Journal
Synthesis and Characterization of Grafted Chitosan Blending with Polyvinyl alcohol / Nanocomposite and Study Biological Activity
...Show More Authors

The study of biopolymers and their derivative materials had received a considerable degree of attention from researchers in the preparation of novel material. Biopolymers and their derivatives have a wide range of applications as a result of their bio-compatibility, bio-degradability and non-toxicity. In this paper, chitosan reacted with different aldehydes(2,4 –dichloro- benzaldehyde or 2-methyl benzaldehyde), different ketones (4-bromoacetophenone or 3-aminoacetophenone) to produce chitosan schiff base (1-4) . Chitosan schiff base (1-4) reacted with glutaric acid or adipic acid in acidic media in distilled water according to the steps of Fischer and Speier to produce compounds (5-12)

... Show More
View Publication Preview PDF
Scopus (13)
Scopus Crossref
Publication Date
Wed Jan 17 2018
Journal Name
Journal Of Engineering And Applied Sciences
PREPARATION, CHARACTERIZATION AND THERMAL ANALYSIS OF POLYMERIC BLEND NANOCOMPOSITES BASED ON PVA-PVPPEGDOPED WITH ZINC OXIDE NANOPARTICLES
...Show More Authors

Publication Date
Mon Oct 01 2012
Journal Name
Applied Energy
Analysis of thermal and electrical performance of a hybrid (PV/T) air based solar collector for Iraq
...Show More Authors

The electrical and thermal performance of a typical single pass hybrid photovoltaic/thermal (PV/T) air collector is modeled, simulated and analyzed for two selected case studies in Iraq. An improved mathematical thermo-electrical model is derived in terms of design, operating and climatic parameters of the hybrid solar collector to evaluate its important characteristics: collector flow and heat removal factors, PV maximum power point and its temperature coefficient, and overall power and efficiency. Unlike previous PV/T thermal models, the present model is obtained with some additions and corrections in radiation and convection heat coefficients for the top loss and for the air duct with more applicable sky temperature correlation. The well

... Show More
View Publication
Scopus (137)
Crossref (121)
Scopus Crossref
Publication Date
Mon Oct 01 2012
Journal Name
Applied Energy
Analysis of thermal and electrical performance of a hybrid (PV/T) air based solar collector for Iraq
...Show More Authors

View Publication
Scopus (137)
Crossref (121)
Scopus Crossref
Publication Date
Wed Jun 21 2017
Journal Name
Research Journal Of Pharmaceutical, Biological And Chemical Sciences
Synthesis and characterization of Mixed-Ligand Complexes of Oxalic Acid and Trimethoprim with Mn(II), Co(II), Ni(II), Cu(II),Zn(II), and Cr (III) Ions: and antimicrobial Activities
...Show More Authors

Publication Date
Sat Oct 01 2016
Journal Name
Arpn Journal Of Engineering And Applied Sciences
Numerical and experimental analysis of transient temperature and residual thermal stresses in friction stir welding of aluminum alloy 7020-T53
...Show More Authors

Scopus (2)
Scopus
Publication Date
Thu Oct 01 2020
Journal Name
Biochemical & Cellular Archives
THE STUDY ON ABILITY OF ESCHERICHIA COLI ISOLATED FROM DIFFERENT CLINICAL CASES TO BIOFILM FORMATION AND DETECTION OF CSGD GENE RESPONSIBLE FOR PRODUCE CURLI (FIMBRIAE)
...Show More Authors

A total of 165 clinical sample included Urine, Swab wounds and Burns were collected from Baghdad Governorate. Results showed that rate all isolates of E. coli was 50(30.3%) and rate of urine infection was 46(92%) and rate of swab wounds infection 4(8%). Where was diagnostic based on streaked on MacConkey agar, then single colony was transferred to Eosin Methylene Blue (EMB). Identification some of the biochemical test included: Catalase test, Oxidase test, Indole test, Methyl red, Vogues - Proskauer test and Citrate Utilization test. Then confirmed by the Vitek - 2 Compact System. The ability of E.coli isolate to biofilm formation to be studied it is considered one of the most important factors of virulence and has role in causing injury an

... Show More
Scopus (4)
Scopus