Preferred Language
Articles
/
pxaCU4cBVTCNdQwC8UXl
Numerical and Experimental Study of Winglet Effect with Different Cant Angles
...Show More Authors

The present work aims to investigate the aerodynamic characteristics of the winglet cant angle of Boeing 737-800 wing numerically and experimentally. The wing contain two swept angles 38.3o and 29.13o respectively, taper ratio 0.15 and aspect ratio 8.04. The wing involves three types of airfoils sections. Four cant angles for blended winglet have been considered (0o, 34o, 60o, 83.3o). The winglet has been analyzed to find the best cant angle for the wing without and with winglet. These models have been tested theoretically at Reynolds number of 2.06 x106 in order to study the winglet aerodynamic characteristics which consist of coefficient of Drag, coefficient of lift and Lift to drag ratio, pitching moment coefficient and bending moment coefficient for (0o, 2o, 4o, 6o, 8o, 10o) angles of attack. SOLIDWORK 2016 software, was used to design the geometry of the wing and winglet. ANSYS FLUENT 17.0 in three dimensions with (k - ε) turbulent model was used to solve the governing equations. The experimental tests were carried out in an open low subsonic wind tunnel of 70cm × 70cm ×150cm test section at Reynolds number of 4.33 x105. The experimental lift, drag forces and pitching moment measurement were considered by three component balance device at different angles of attack. The results show that 34o cant angle is the best angle, at which 2-3% increase in lift coefficient, 2-3.9% decrease in drag coefficient, 3.5-6% increase in pitching moment coefficient and 3-6.6% increase in lift to drag coefficient by using blended winglet. Good agreement between the experimental and computational results are shown.

Publication Date
Fri May 31 2019
Journal Name
Journal Of Engineering
Numerical Investigation of Heat Transfer Enhancement of Double Pipe Heat Exchanger Using Metal Foam Fins
...Show More Authors

The influence of adding metal foam fins on the heat transfer characteristics of an air to water double pipe heat exchanger is numerically investigated. The hot fluid is water which flows in the inner cylinder whereas the cold fluid is air which circulates in the annular gap in parallel flow with water. Ten fins of metal foam (Porosity = 0.93), are added in the gap between the two cylinder, and distributed periodically with the axial distance. Finite volume method is used to solve the governing equations in porous and non-porous regions. The numerical investigations cover three values for Reynolds number (1000 ,1500, 2000), and Darcy number (1 x10-1, 1 x10-2, 1x10-3). The comparison betwee

... Show More
View Publication Preview PDF
Crossref (8)
Crossref
Publication Date
Mon Sep 01 2014
Journal Name
Al-khwarizmi Engineering Journal
Numerical Investigation of Transient Heat Conduction through a Thermal Insulation of Temperature Dependant Thermal Properties
...Show More Authors

The two-dimensional transient heat conduction through a thermal insulation of temperature dependent thermal properties is investigated numerically using the FVM. It is assumed that this insulating material is initially at a uniform temperature. Then, it is suddenly subjected at its inner surface with a step change in temperature and subjected at its outer surface with a natural convection boundary condition associated with a periodic change in ambient temperature and heat flux of solar radiation. Two thermal insulation materials were selected. The fully implicit time scheme is selected to represent the time discretization. The arithmetic mean thermal conductivity is chosen to be the value of the approximated thermal conductivity at the i

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 09 2016
Journal Name
Journal Of The College Of Basic Education
Study the effect of Thymus vulgaris on the weight of Liver and Kidneys in Albino male rats
...Show More Authors

Publication Date
Sun Feb 26 2012
Journal Name
Ibn Al-haitham Journal For Pure And Applied Science
Study the Effect of Annealing Temperature on the Structural, Optical and Electrical Properties of ZnS Thin Films
...Show More Authors

The structural, optical and electrical properties of ZnS films prepared by vacuum evaporation technique on glass substrate at room temperature and treated at different annealing temperatures (323, 373, 423)K of thickness (0.5)µm have been studied. The structure of these films is determined by X-ray diffraction (XRD). The X-ray diffraction studies show that the structure is polycrystalline with cubic structure, and there are strong peaks at the direction (111). The optical properties investigated which include the absorbance and transmittance spectra, energy band gab, absorption coefficient, and other optical constants. The results showed that films have direct optical transition. The optical band gab was found to be in the range t

... Show More
Publication Date
Sat Jan 02 2021
Journal Name
Kerbala Journal Of Pharmaceutical Sciences
Study the Effect of Disintegrant Types on Preparation and In-Vitro Evaluation of Salbutamol Sulfate Effervescent Granules
...Show More Authors

Publication Date
Wed Apr 01 2020
Journal Name
Indian Journal Of Ecology,
Effect of foliar spraying with bilirubin on growth traits of wheat varieties
...Show More Authors

Scopus (4)
Scopus
Publication Date
Thu Jan 01 2015
Journal Name
Aip Conference Proceedings
Numerical solution for weight reduction model due to health campaigns in Spain
...Show More Authors

This paper introduces a non-conventional approach with multi-dimensional random sampling to solve a cocaine abuse model with statistical probability. The mean Latin hypercube finite difference (MLHFD) method is proposed for the first time via hybrid integration of the classical numerical finite difference (FD) formula with Latin hypercube sampling (LHS) technique to create a random distribution for the model parameters which are dependent on time t . The LHS technique gives advantage to MLHFD method to produce fast variation of the parameters’ values via number of multidimensional simulations (100, 1000 and 5000). The generated Latin hypercube sample which is random or non-deterministic in nature is further integrated with the FD method t

... Show More
View Publication
Scopus (4)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Possible Augmentive Effect of Antioxidant Vitamin C in Patients with Essential Hypertension Treated with Amlodipin or Enalapril
...Show More Authors

Hypertension is identified as one of the most significant risk factors for cardiovascular diseases (CVDs). There is growing evidence showing that oxidative stress plays a major role in hypertension. Increased production of reactive oxygen species and decrease bioavailability of antioxidant have been demonstrated in experimental and human hypertension. The present study was directed to determine the beneficial effect of the antioxidant vitamin C in patients with essential hypertension treated with the calcium channel blocker (amlodipine) or with the angiotensin converting enzyme inhibitor (enalapril). Ninety six patients (50 females and 46 males) with essential hyp

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon May 15 2017
Journal Name
Ibn Al- Haitham J. For Pure & Appl. Sci.
Conductometric Studies of Aqueous Solution of Thymine and Adenosine At Different Temperatures
...Show More Authors

Molar conductivity of different concentrations of thymine and adenosine in water , sodium acetate and ammonium chloride solution at different temperatures , 283. 15-323.15 K has been determined from direct conductivity measurements , examination of aqueous mixture of thymine and adenosine with Onsager equation reveal deviation from linearity at high concentration .This deviation was explained in term of molecular interaction . Ostwald dilution law also examined with the above mixtures lead to calculation of limiting molar conductivities and dissociation constants of both nucleic acid in water , sodium acetate and ammonium chloride. The agreement between the values obtained for Onsager equa

... Show More
Publication Date
Thu Jun 30 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Thermal Osmosis of Mixtures of Water and Organic Compounds through Different Membranes
...Show More Authors

The present work aimed to study the efficiency of thermal osmosis process for recovery of water from organic wastewater solution and study the factors affecting the performance of the osmosis cell. The driving force in the thermo osmosis cell is provided by a difference in temperature across the membrane sides between the draw and feed solution. In this research used a cellulose triacetate (CTA), as flat sheet membranes for treatment of organic wastewater under orientation membrane of active layer facing feed solution (FS) and draw solution (DS) is placed against the support layer.  The organic materials were phenol, toluene, xylene and BTX (benzene, toluene, and xylene) used as feed solution. The osmotic agent in draw solution was

... Show More
View Publication Preview PDF