Preferred Language
Articles
/
pRf7LZIBVTCNdQwC96fn
Poly-ether-ether-ketone (PEEK) versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 1. Stability, retainer failure, and participant satisfaction
...Show More Authors
Abstract<sec> <title>Background

Poly-ether-ether-ketone (PEEK) was introduced in dentistry as an alternative to metal alloys.

Objective

To assess the effectiveness of PEEK-fixed retainers in preserving the stability of mandibular anterior and participant satisfaction as compared to the Dead-soft coaxial fixed retainer (DSC).

Trial design

A single-centre, two-arm parallel groups randomized clinical trial.

Methods

The patients treated with pre-adjusted orthodontic appliances who have a Little’s Irregularity Index (LII) ≤ 0.5 mm have been enrolled in the trial. PEEK retainers were prepared to round 0.8 mm wire by computer-aided design and manufacturing, and the DSC wire was carefully adapted to the lingual surface of the lower anterior teeth. The primary outcome was the stability of lower anterior teeth as assessed by LII, while the secondary outcomes were changes in occlusal parameters, retainer failure, and patient satisfaction. The data were collected at the debonding stage (T0), 1 month (T1), 3 months (T3), and 6 months (T6) after starting the trial, except for patient’s satisfaction, which was recorded using an electronic form at T1 and T6.

Blinding

Single blinding of participants.

Results

A total of 46 participants with an age range of 12–28 years old were randomly allocated to the two groups (n = 23 in each). Only one participant dropped out; therefore, 45 participants were analysed. The DSC group showed a significant increase in LII at T3. Both retainer groups had comparable occlusal measurements, failure frequency, and survival time, with no significant difference. The patients in the DSC group reported a statistically significant perception of change in the position of their teeth compared to those in the PEEK group.

Harms

No harmful effects have been reported.

Limitations

Limited follow-up duration and the inability to blind the operator due to the nature of the intervention.

Conclusions

After 6-month retention, the PEEK retainer was equally effective to DSC retainers in maintaining the teeth alignment, with no significant differences regarding the failure frequency, survival rate, and general patient satisfaction.

Trial registration

https://register.clinicaltrials.gov. (NCT05557136).

Scopus Clarivate Crossref
View Publication
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Study of the Effect of Berry Paper Mulberry on Optical Properties of Poly Methyl Methacrylate
...Show More Authors

In this work, study the optical properties of composites consisting of poly Methyl Methacrylate and Berry Paper Mulberry. The samples of composites were prepared using casting method .The Berry Paper Mulberry (BPM) was added by different concentrations are (0, 2, 4 and 6)wt.%. The optical properties of composites have been studied in the wavelength range (200-800)nm. The absorption coefficient ,energy gap, refractive index, extinction coefficient and dielectric constants have been determined. The results show that the optical constants change with increase of BPM concentrations .

View Publication Preview PDF
Crossref
Publication Date
Wed Mar 29 2023
Journal Name
Journal Of Optics
Enhancement of photodetector biased of ZnO nanoparticles/poly-TPD organic material by PEDOT PSS layer
...Show More Authors

View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Mon Jun 22 2020
Journal Name
Baghdad Science Journal
Studying the Effect of Magnesium Oxide Nanoparticles Prepared on the Surface of Poly Methyl Methacrylate
...Show More Authors

          In this paper, magnesium oxide nanoparticles (MgO NPS) have been prepared and characterized and its concentration effect has been studied on polymers surface (MgO NPS). The results showed that the degradation of poly methyl methacrylate increased when using such metal oxide. The results also showed that the metal oxide increased the degradation of poly methyl methacrylate. X-ray diffraction, scanning electron microscopy, atomic force microscopy were used to study the morphological characteristics and size of nano MgO particles analysis.  Films were prepared by mixing the different masses of MgO NPS (0.025, 0.05, 0.1, 0.2 and 0.4) % with a polymer solution ratio (W/V) 7 %. Photo-

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Baghdad Science Journal
Natural Pigment –Poly Vinyl Alcohol Nano composites Thin Films for Solar Cell: nanocomposites thin film
...Show More Authors

Solar cells thin films were prepared using polyvinyl alcohol (PVA) as a thin film, with extract of natural pigment from local flower. A concentration of 0.1g/ml of polyvinyl alcohol solution in water was prepared for four samples, with various concentrations of plant pigment (0, 15, 25 and 50) % added to each of the four solutions separately for preparing (PVA with low concentrated dye , PVA with medium concentrated dye and PVA with high concentrated dye ) thin films respectively . Ultraviolet absorption regions were obtained by computerized UV-Visible (CECIL 2700). Optical properties including (absorbance, reflectance, absorption coefficient, energy gap and dielectric constant) via UV- Vis were tested, too.  Fourier transform infra

... Show More
View Publication Preview PDF
Scopus (28)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Fri Aug 15 2025
Journal Name
Baghdad Science Journal
Corrosion Protection of Copper in Salt Medium by Poly 4-Hyroxyaniline Deposited via Electrodeposition Technique
...Show More Authors

The polymer was used to inhibit the corrosion of copper metal in salt media in different concentrations at room temperature using potentiometric polarization measurement. The polymer was prepared by mixing (0.1 M) 4-Hydroxy aniline (C6H7NO) with (0.25M) of ammonium persulfate as the initiator using the electro-deposition technique. The polymer’s results showed that copper in (3.5%) NaCl had good corrosion resistance. The findings demonstrate that the %IE for polymer-induced copper corrosion is 89.32% at 10 ppm concentration as a result of the 4-hydroxy aniline polymer’s adsorption from salt solution on the surface of copper metal. The numbers from the polarization method and the acquired standard data agree well. The coated copper by po

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Aug 15 2025
Journal Name
Baghdad Science Journal
Corrosion Protection of Copper in Salt Medium by Poly 4-Hyroxyaniline Deposited via Electrodeposition Technique
...Show More Authors

The polymer was used to inhibit the corrosion of copper metal in salt media in di erent concentrations at room temperature using potentiometric polarization measurement. The polymer was prepared by mixing (0.1 M) 4-Hydroxy aniline (C6H7NO) with (0.25M) of ammonium persulfate as the initiator using the electro-deposition technique. The polymer’s results showed that copper in (3.5%) NaCl had good corrosion resistance. The ndings demonstrate that the %IE for polymer-induced copper corrosion is 89.32% at 10 ppm concentration as a result of the 4-hydroxy aniline polymer’s adsorption from salt solution on the surface of copper metal. The numbers from the polarization method and the acquired standard data agree well. The coated copper by poly

... Show More
Scopus Crossref
Publication Date
Fri May 22 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of en-masse retraction using microimplant versus conventional techniques: An in vitro study
...Show More Authors

Background: The study aimed to investigate the effect of different techniques of en masse retraction on the vertical and sagittal position, axial inclination, rate of space closure, and type of movement of maxillary central incisor. Materials and methods: A typodont simulation system was used (CL II division 2 malocclusion). Three groups were used group 1(N=10, T-loop), group 2(N=10, Time-Saving loop), and group 3(N=10, Microimplant). Photographs were taken before and after retraction and measurements were made using Autodesk AutoCAD© software 2010. Kruskal-Wallis one-way analyses of variance and Mann-Whitney U test (p?0.05) were used. Results: The rate of space closure showed no significant difference among the three groups (p?0.05), whi

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 01 2018
Journal Name
European Journal Of General Medicine
The Value of Longitudinal Strain versus Coronary Angiography in Detection of Coronary Artery Disease
...Show More Authors

Aims: The aim of this study was to evaluate the value and accuracy of longitudinal strain in detection of coronary artery disease compared to coronary angiography. Results: The left ventricular longitudinal strain-speckle tracking showed evidence of stenosis of left anterior descending artery, circumflex artery and right coronary artery in (86.1%), (76.4%), and (84.7%) respectively. For the stenosis in left anterior descending artery, the current study showed that the longitudinal strain was a good predictor for presence of significant stenosis with a sensitivity of (93.8%), specificity (75%) and accuracy (91.7%) compared with coronary angiography. For the stenosis in right coronary artery, the left ventricular longitudinal strain had

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Medico-legal Update
Flexible ureterorenoscopy versus extracorporeal shock wave lithotripsy for treatment of lower pole renal stones
...Show More Authors

Scopus (1)
Scopus
Publication Date
Sat Mar 08 2025
Journal Name
Chemistry Africa
Preparation, Characterisation, and Photochemical Stability of Polymeric Derivatives of Polyvinyl Alcohol Grafted with Phthalic Anhydride and Dyes
...Show More Authors

In this study, derivatives of polyvinyl alcohol (PVA) grafted with phthalic anhydride (PhA) and dyes were prepared to produce polymeric materials of PVA-g-PhA, PVA-g-PhA-anthocyanin, PVA-g-PhA-bromophenol blue, and PVA-g-PhAthymol blue. The materials were characterised by FTIR and 1 H NMR spectroscopies. The crystallinity of the polymers was evaluated with powder X-ray difraction, and the thermal stability by thermogravimetric analysis (TGA). The synthetic procedure for the polymeric materials entailed the formation of esters. The FTIR spectra of the polymers confrmed their formation since the ester carbonyl group stretch was observed at approximately 1691–1716  cm−1 in each material. NMR spectroscopy confrmed the addition of t

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref