Preferred Language
Articles
/
pRf7LZIBVTCNdQwC96fn
Poly-ether-ether-ketone (PEEK) versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 1. Stability, retainer failure, and participant satisfaction
...Show More Authors
Abstract<sec> <title>Background

Poly-ether-ether-ketone (PEEK) was introduced in dentistry as an alternative to metal alloys.

Objective

To assess the effectiveness of PEEK-fixed retainers in preserving the stability of mandibular anterior and participant satisfaction as compared to the Dead-soft coaxial fixed retainer (DSC).

Trial design

A single-centre, two-arm parallel groups randomized clinical trial.

Methods

The patients treated with pre-adjusted orthodontic appliances who have a Little’s Irregularity Index (LII) ≤ 0.5 mm have been enrolled in the trial. PEEK retainers were prepared to round 0.8 mm wire by computer-aided design and manufacturing, and the DSC wire was carefully adapted to the lingual surface of the lower anterior teeth. The primary outcome was the stability of lower anterior teeth as assessed by LII, while the secondary outcomes were changes in occlusal parameters, retainer failure, and patient satisfaction. The data were collected at the debonding stage (T0), 1 month (T1), 3 months (T3), and 6 months (T6) after starting the trial, except for patient’s satisfaction, which was recorded using an electronic form at T1 and T6.

Blinding

Single blinding of participants.

Results

A total of 46 participants with an age range of 12–28 years old were randomly allocated to the two groups (n = 23 in each). Only one participant dropped out; therefore, 45 participants were analysed. The DSC group showed a significant increase in LII at T3. Both retainer groups had comparable occlusal measurements, failure frequency, and survival time, with no significant difference. The patients in the DSC group reported a statistically significant perception of change in the position of their teeth compared to those in the PEEK group.

Harms

No harmful effects have been reported.

Limitations

Limited follow-up duration and the inability to blind the operator due to the nature of the intervention.

Conclusions

After 6-month retention, the PEEK retainer was equally effective to DSC retainers in maintaining the teeth alignment, with no significant differences regarding the failure frequency, survival rate, and general patient satisfaction.

Trial registration

https://register.clinicaltrials.gov. (NCT05557136).

Scopus Clarivate Crossref
View Publication
Publication Date
Thu Sep 16 2021
Journal Name
Journal Of Advance Research In Chemical Sciences
Study of Schiff Bases Complexes of Trimethoprim: A Review
...Show More Authors

Trimethoprim derivative Schiff bases are versatile ligands synthesized with carbonyl groups from the condensation of primary amines (amino acids). Because of their broad range of biological activity, these compounds are very important in the medical and pharmaceutical fields. Biological activities such as antibacterial, antifungal and antitumor activity are often seen. Transition metal complexes derived from biological activity Schiff base ligands have been commonly used

Publication Date
Thu Mar 09 2017
Journal Name
Sensors
A Multimodality Hybrid Gamma-Optical Camera for Intraoperative Imaging
...Show More Authors

The development of low profile gamma-ray detectors has encouraged the production of small field of view (SFOV) hand-held imaging devices for use at the patient bedside and in operating theatres. Early development of these SFOV cameras was focussed on a single modality—gamma ray imaging. Recently, a hybrid system—gamma plus optical imaging—has been developed. This combination of optical and gamma cameras enables high spatial resolution multi-modal imaging, giving a superimposed scintigraphic and optical image. Hybrid imaging offers new possibilities for assisting clinicians and surgeons in localising the site of uptake in procedures such as sentinel node detection. The hybrid camera concept can be extended to a multimodal detec

... Show More
View Publication
Scopus (24)
Crossref (25)
Scopus Clarivate Crossref
Publication Date
Wed Sep 30 2020
Journal Name
College Of Islamic Sciences
Saba is a semantic study of examples of pronouns
...Show More Authors

which is much useful in the Arabic Language generally in the Holly Quran especially. It is the pronoun  I have taken in the semantic aspect from it and I have done on the surra sabba which varities  the semantical pronoun in it among the pronoun of the speaker the conscience of the addressee the absent  such the the siprat pronoun that comes in it with the explanation for its importance and its work and this is the subject of the first unit which I advanced it from the concept of the pronoun Linguistically and convention. After that I have lighten in some meanings which I have done in the surrat as a semantic , magnification , proud, reprimand and others which I ended my research I have reached the results from it

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 01 2016
Journal Name
International Journal Of Pure And Apllied Mathematics
A SEMI ANALYTICAL ITERATIVE TECHNIQUE FOR SOLVING DUFFING EQUATIONS
...Show More Authors

View Publication
Crossref (13)
Crossref
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Review of the Electrical Submersible Pump Development Chronology
...Show More Authors

The electric submersible pump, also known as ESP, is a highly effective artificial lift method widely used in the oil industry due to its ability to deliver higher production rates compared to other artificial lift methods. In principle, ESP is a multistage centrifugal pump that converts kinetic energy into dynamic hydraulic pressure necessary to lift fluids at a higher rate with lower bottomhole pressure, especially in oil wells under certain bottomhole condition fluid, and reservoir characteristics. However, several factors and challenges can complicate the completion and optimum development of ESP deployed wells, which need to be addressed to optimize its performance by maximizing efficiency and minimizing costs and uncertainties. To

... Show More
View Publication Preview PDF
Crossref (11)
Crossref
Publication Date
Fri Jul 01 2016
Journal Name
Journal Of Engineering
Aluminum Rubbish as a Coagulant for Oily Wastewater Treatment
...Show More Authors

In this study an experimental work was done to study the possibility of using aluminum rubbish material as a coagulant to remove the colloidal particles from oily wastewater by dissolving this rubbish in sodium hydroxide solution. The experiments were carried out on simulated oily wastewater that was prepared at different oil concentrations and hardness levels (50, 250, 500, and 1000) ppm oil for (2000, 2500, 3000, and 3500) ppm CaCo3 respectively. The initial turbidity values were (203, 290, 770, and 1306) NTU, while the minimum values of turbidity that have been gained from the experiments in NTU units were (1.67, 1.95, 2.10, and 4.01) at best sodium aluminate dosages in milliliters (12, 20, 24, and 28) for

... Show More
View Publication Preview PDF
Publication Date
Sun May 01 2022
Journal Name
Journal Of Engineering
Parametric Study of a Two-Phase Closed Thermosyphon Loop
...Show More Authors

A theoretical and experimental investigation was carried out to study the behavior of a two-phase closed thermosyphon loop (TPCTL) during steady-state operation using different working fluids. Three working fluids were investigated, i.e., distilled water, methanol, and ethanol. The TPCTL was constructed from an evaporator, condenser, and two pipelines (riser and downcomer). The driving force is the difference in pressure between the evaporator and condenser sections and the fluid returns to the heating section by gravity. In this study, the significant parameters used in the experiments were filling ratios (FR%) of 50%, 75%, and 100% and heat-input range at the evaporator section of 215-860.2 W. When the loop reached to

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Dec 09 2021
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Exacerbation of COVID 19 in Hypertensive Patients ( A review)
...Show More Authors

Since its discovery in December 2019, corona virus was outbreak worldwide with very rapid rate, so it described by WHO as pandemic. It associated with severe acute respiratory distress syndrome, and can enter to cells through Angiotensin Converting Enzyme 2 (ACE 2) receptor which play an important role as regulator for blood pressure. Hypertension is a potential risk factor for sever acute respiratory syndrome COVID-19, and associated with high mortality rate as shown in many epidemiological studies. Moreover, specific antihypertensive medications that infected patients were receiving are not known; only data about renin-angiotensin-aldosterone system (RAAS) are available.  

View Publication Preview PDF
Scopus (6)
Crossref (6)
Scopus Crossref
Publication Date
Fri Aug 09 2024
Journal Name
Theory And Practice In Language Studies
Fallacy as a Strategy of Argumentation in Political Debates
...Show More Authors

This study aims to study argumentation in political debates by figuring out the logical fallacies employed in the debates of Clinton and Trump, the presidential nominees of the 2016 elections, and Biden and Trump, the leading contenders in the 2020 United States presidential election. The study attempts to answer the questions: (1) What relevance fallacies are adopted in the debate between Trump and Clinton? (2) What rhetorical devices are used to influence the audience and gain voters besides fallacies in the debates selected? The study analyses two texts from two arguments using Damer's (2009) taxonomy of relevance fallacy and rhetorical devices based on Perrine’s (1969) model of communication and interpersonal rhetoric to answe

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Fri Jun 11 2021
Journal Name
Journal Of Computing And Information Technology
A Survey on Emotion Recognition for Human Robot Interaction
...Show More Authors

With the recent developments of technology and the advances in artificial intelligent and machine learning techniques, it becomes possible for the robot to acquire and show the emotions as a part of Human-Robot Interaction (HRI). An emotional robot can recognize the emotional states of humans so that it will be able to interact more naturally with its human counterpart in different environments. In this article, a survey on emotion recognition for HRI systems has been presented. The survey aims to achieve two objectives. Firstly, it aims to discuss the main challenges that face researchers when building emotional HRI systems. Secondly, it seeks to identify sensing channels that can be used to detect emotions and provides a literature review

... Show More
View Publication Preview PDF
Scopus (20)
Crossref (7)
Scopus Crossref