Preferred Language
Articles
/
pRdAjZABVTCNdQwCfIxD
Determination microstructure parameters for copper oxide nanoparticles
...Show More Authors

In this research, the results of x-ray diffraction method were used to determine the uniform stress deformation and microstructure parameters of CuO nanoparticles to determine the lattice strain obtained and crystallite size and then to compare the results obtained by two model Halder Wagner and Size Strain Plot with the results of these methods of the same powder using equations during which the calculation of the size of the crystallite size and lattice strain, It was found that the results obtained the values of the crystallite size (19.81nm) and the lattice strain (0.004065) of the Halder-wagner model respectively and for the ssp method were the results of the crystallite size (17.20nm) and lattice strain (0.000305) respectively. The sample was taken into consideration In order to calculate physical and microstructural characteristics including internal strain, dislocations density, surface area, the number of unit cells, and texture coefficient.

Scopus Crossref
View Publication
Publication Date
Fri Jun 30 2017
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Improving of Design Parameters of an Industrial Continuous Catalytic Reforming Reactors
...Show More Authors

Catalytic reforming of naphtha occupies an important issue in refineries for obtaining high octane gasoline and aromatic compounds, which are the basic materials of petrochemical industries. In this study, a novel of design parameters for industrial continuous catalytic reforming reactors of naphtha is proposed to increase the aromatics and hydrogen productions. Improving a rigorous mathematical model for industrial catalytic reactors of naphtha is studied here based on industrial data applying a new kinetic and deactivation model. The optimal design variables are obtained utilizing the optimization process in order to build the model with high accuracy and such design parameters are then applied to get the best configuration of this pro

... Show More
View Publication Preview PDF
Publication Date
Sat Apr 06 2024
Journal Name
Indian Journal Of Physics
Investigating the effect of alternating voltage frequency on plasma jet parameters
...Show More Authors

View Publication
Scopus (1)
Scopus
Publication Date
Sun Sep 07 2008
Journal Name
Baghdad Science Journal
A Study of some biochemical parameters in patients with - thalassemia
...Show More Authors

Serum levels of iron,copper,ceruloplasmin and transferrine were estimated in three groups of patients with ?- thalassemia: 24 patients have splenectomy thalassemia major, 29 patients have non splenectomy thalassemia major and 19 patients have thalassemia intermedia , data were compared to normal and pathological controls (anemia and minor). There were significant increase in trace element levels in all studied groups of pateints as compared to normal and pathological controls. Also there were a significant increase in ceruloplasmin levels,While the result revealed that there were a significant decrease in transferrine levels in all groups of patients studied as compared to normal and pathological controls. The result also indicate that the

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Global Pharma Technology
Some Biochemical Parameters in Congestive Heart Failure Patients in Baghdad City
...Show More Authors

Scopus
Publication Date
Mon Jun 04 2018
Journal Name
Baghdad Science Journal
The Effect of Gas Flow on Plasma Parameters Induced by Microwave
...Show More Authors

In this paper, construction microwaves induced plasma jet(MIPJ) system. This system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate by using flow meter, to diagnose microwave plasma optical emission spectroscopy(OES) was used to measure the important plasma parameters such as electron temperature (Te), residence time (Rt), plasma frequency (?pe), collisional skin depth (?), plasma conductivity (?dc), Debye length(?D). Also, the density of the plasma electron is calculated with the use of Stark broadened profiles

View Publication Preview PDF
Scopus (20)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
Streams and plasma parameters experimental studies in He-CO gas mixtures
...Show More Authors

DC glow discharges were generated between a thin cylindrical anode and a flat cathode, streamers are thought to propagate by photo-ionization; the parameters of photo-ionization depend on the He: CO ratio. Therefore we study streamers in He ( 90%, 80% and 70% ) with (10%, 20% and 30%) CO respectively. The streamer diameter is essentially the change by increase for similar voltage and pressure in all He-CO mixtures.

View Publication Preview PDF
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Clinical Evaluation of Some Biochemical Parameters from Patients in Heamodialysis Room
...Show More Authors

As a marker of systemic inflammation, raised (C-reactive protein (CRP)) concentrations which are still within the normal range have been associated with an increased inflammation of chronic renal diseases (CRD). The current study aimed to establish potential determinats of raised CRP concentrations in patients who treated in Heamodialysis room,then study the relationship between CRP& some biochemical parameters related CRD We used a CRP latex reagents Kit which is based on an immunological reaction between CRP antisera bounded to the biologically inert latex particles or with CRP in the test specimens of 19 patients with (CRD) mean age 48 years ,range = 30?65 & in 21 healthy subjects as control group their age range = 30 ?45 years. The

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat May 25 2024
Journal Name
Optical And Quantum Electronics
Enhancing plasma jet parameters control by external magnetic field strength variation
...Show More Authors

Abstract This research scrutinizes the impact of external magnetic field strength variations on plasma jet parameters to enhance its performance and flexibility. Plasma jets are widely used for their high thermal and kinetic energy in both medical and industrial fields. The study employs optical emission spectroscopy to measure electron temperature, electron density, and plasma frequency in a plasma jet subjected to varying magnetic field strengths (25, 50, 100, 150, and 250 mT). The results indicate that a stronger magnetic field results in higher electron temperature (1.485 to 1.991 eV), electron density (5.405 × 1017 to 7.095 × 1017), and plasma frequency 7.382 × 1012 to 8.253 × 1012 Hz. As well as the research investigates the influ

... Show More
View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri Oct 31 2025
Journal Name
International Review On Modelling And Simulations (iremos)
Denavit-Hartenberg Parameters in the Kinematic Design of Prosthetic Finger Modules
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Tue Mar 30 2010
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Separation of Bovine Serum Albumin Using Chromatographical Column: Parameters and Simulation
...Show More Authors

A liquid-solid chromatography of Bovine Serum Albumin (BSA) on (diethylaminoethyl-cellulose) DEAE-cellulose adsorbent is worked experimentally, to study the effect of changing the influent concentration of (0.125, 0.25, 0.5, and 1 mg/ml) at constant volumetric flow rate Q=1ml/min. And the effect of changing the volumetric flow rate (1, 3, 5, and 10 ml/min) at constant influent concentration of Co=0.125mg/ml. By using a glass column of (1.5cm) I.D and (50cm) length, packed with adsorbent of DEAE-cellulose of height (7cm). The influent is introduced in to the column using peristaltic pump and the effluent concentration is investigated using UV-spectrophotometer at 30oC and 280nm wavelength. A spread (steeper) break-through curve is gained

... Show More
View Publication Preview PDF