Preferred Language
Articles
/
pRYzLIcBVTCNdQwCODtn
Increasing confidence in full field modelling and water flood planning for a giant reservoir under primary depletion through Material Balance modelling
...Show More Authors
Abstract<p>One of the principle inputs to project economics and all business decisions is a realistic production forecast and a practical and achievable development plan (i.e. waterflood). Particularly this becomes challenging in supergiant oil fields with medium to low lateral connectivity. The main objectives of the Production Forecast and feasibility study for water injection are:</p><p>1- Provide an overview of the total expected production profile, expected wells potential/spare capacity, water breakthrough timing and water cut development over time</p><p>2- Highlight the requirements to maintain performance, suggest the optimum development pattern</p><p>3- Increasing confidence in business decisions to develop the reservoir in question</p><p>The main tool used for these purposes is a sophisticated reservoir simulation software, namely CMG©, since it can predict reservoir behavior, honor physical constraints and capture the heterogeneity within the reservoir to accurately predict performance. However, the starting point for this kind of complicated studies needs to start from the basics, in order to understand the big picture and be able to plan properly for the scope to be delivered, hence, utilizing analytical tools like MBAL becomes quite necessary, if not crucial, to the success of full field modelling and choosing an optimum water flood pattern and design.</p><p>This paper covers the methodology for building the reservoir component utilizing a Material Balance model, of which the results will be used as an input to reservoir simulation to evaluate and accurately predict reservoir performance, which directly feeds into planning for water flooding projects and selection of an optimum flood pattern.</p><p>A Tank model was built at first to assess and understand the driving forces (energies) of the reservoir in question, utilizing pressure and production data from legacy wells, the prepared model is also supported by geological and petro physical studies to give representative results. Acquired Static Bottom Hole Pressures (SBHPs) in wells were used as anchor points for the tank pressure and to test the validity of the history match. Multiple analytical methods to QC the results and STOIIP volume were conducted, e.g. the Havlena-Odeh method.</p><p>This methodology has been tested successfully in the stated super giant oil field, in which the reservoir in question is a carbonate rock formation. An example of this is covered in the paper. It was concluded that utilizing a history matched and coherent MBAL model before conducting a detailed reservoir simulation study can save a lot of time and effort by providing guidance to the path which needs to be followed, and sheds light on the critical elements to be looked after. This has also helped to uncover the driving mechanisms and energies in the reservoir, hence allowing the engineer to plan for the necessary voidage replacement and water injection rates to sustain the reservoir pressure and pattern development. Another technical advantage of the described method is the higher sustainability of the model.</p><p>The suggested method, in combination with geological and petro physical information available, can be applied to majority of the reservoirs. This combination is paramount to ensure optimum time and planning that is followed for each reservoir development study that involves water flooding.</p>
Scopus Crossref
View Publication
Publication Date
Thu Sep 01 2022
Journal Name
Iop Conference Series: Earth And Environmental Science
Monitoring the Water Quality of Tigris River by Applied Overall Index of Pollution
...Show More Authors
Abstract<p>The alteration in the hydrological regime in Iraq and the anthropogenic increasing effect on water quality of a lotic ecosystems needs to continuous monitoring. This work is done to assess the water quality of Tigris River within Baghdad City. Five sites were selected along the river and ten physicochemical parameters and Overall Index of Pollution (OIP) were applied to assess the water quality for the period between November 2020 and May 2021, the studied period were divided into dry and wet seasons. These parameters were water temperature, pH, dissolved oxygen (DO), biological oxygen demand (BOD), total hardness, alkalinity, turbidity, total phosphorus, total nitrogen, electrical co</p> ... Show More
View Publication Preview PDF
Scopus (8)
Crossref (3)
Scopus Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
Adsorption of heavy metal ions using activated carbon derived from Eichhornia (water hyacinth)
...Show More Authors
Abstract<p>Removal of heavy metal ions such as, cadmium ion (Cd <sup>2+</sup>) and lead ion (Pb <sup>2+</sup>) from aqueous solution onto Eichhornia (water hyacinth) activated carbon (EAC) by physiochemical activation with potassium hydroxide (KOH) and carbon dioxide (CO<sub>2</sub>) as the activating agents were investigated. The Eichhornia activated carbon was characterized by Brunauer Emmett Teller (BET), Fourier Transform Infrared spectroscopy (FTIR), and Scanning Electron Microscopy (SEM) techniques. Whereas, the effect of adsorbent dosage, contact time of pH, and metal ion concentration on the adsorption process have been investigated using the batch process t</p> ... Show More
View Publication
Scopus (22)
Crossref (12)
Scopus Crossref
Publication Date
Mon Dec 11 2017
Journal Name
Al-khwarizmi Engineering Journal
Evaluations of Potable Water Tanks Epoxy Coatings Performance Using Electrochemical Impedance Spectroscopic Method
...Show More Authors

Abstract  

The aim of this paper is to investigate and discuss the mechanisms of corrosion of epoxy coatings used for potable water tanks. Two distinct types of Jotun epoxy coatings: Tankguard 412 contained polyamine cured epoxy and Penguard HB contained polyamide cured epoxy, were tested and studied using the electrochemical impedance spectroscopic (EIS) method. The porosity of epoxy coatings was determined using EIS method. The obtained results showed that the two epoxy coatings have excellent behavior when applied and tested in potable water of Basrah city. Polyamine is more resistance to water corrosion compared to polyamide curing epoxy and has high impedance values. Microscopic inspection after te

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Fri Mar 31 2017
Journal Name
Al-khwarizmi Engineering Journal
Antibacterial Activity of Electrospun Silver Nitrate /Nylon 6 Polymeric Nanofiber Water Filtration Mats
...Show More Authors

Bacterial water pollution is a genuine general wellbeing concern since it causes various maladies. Antimicrobial nanofibers can be integrated by incorporating nanobiocides, for example, silver nanoparticles into nanofibers. Nylon 6 was dissolved in formic acid at a concentration of (25 wt. %) and tough antibacterial (AgNO3/Nylon) nanofibers were produced utilizing electrospinning system. Polymer solution was tested before accomplishing electrospinning process to acquire its surface tension, electric conductivity and viscosity, where every one of those parameters increased relatively with increasing concentration of (AgNO3) additions. SEM and EDX spectra were utilized to focus on the morphology, surface elemental mem

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Thu Jun 30 2016
Journal Name
Iraqi Geological Journal
ASSESSMENT OF GROUNDWATER QUALITY USING WATER QUALITY INDEXIN, AL-HAWIJA AREA, NORTHERN IRAQ
...Show More Authors

The quality of groundwater in the Al-Hawija area was assessed using a water quality index. Data of nine physico-chemical parameters of 28 groundwater wells were used to calculate the water quality index (WQI). A heterogeneous water quality was reported, where in close proximity to the Lesser Zab River (LZR), it has low WQI values and permissible for human consumptions due to the dilution processes by fresh water; whereas, it becomes deteriorated in areas located far away the river. The values of WQI ranges from 22 to 336, indicating a good to very poor groundwater quality.

View Publication
Crossref (2)
Crossref
Publication Date
Mon Dec 03 2018
Journal Name
Journal Of Engineering
Studying the Effects of Different Polymers on Rheological Properties of Water Base Muds
...Show More Authors

This research is focusing on finding more effective polymers that leads to enhance the rheological properties of Water Base Muds. The experiments are done for different types of mud for all substances which are Polyacrylamide, Xanthan gum, CMC (Carboxyl Methyl Cellulose). This study shows the effect of add polymer to red bentonite mud, effect of add polymer to Iraqi bentonite mud, the effect of add bentonite to polymer mud. The mud properties of Iraqi bentonite blank are enhanced after adding the polymers to the blank mix, CMC gives the highest value of plastic viscosity and Gel strength than others; X-anthan gives the highest value of yield point and gel strength than others. For the red bentonite mud, Polyacrylamide has the highes

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Sat Oct 01 2022
Journal Name
Baghdad Science Journal
Assessment of surface water quality using statistical analysis methods: Orontes River (Case study)
...Show More Authors

The study investigates the water quality of the Orontes River, which is considered one of the important water recourses in Syria, as it is used for drinking, irrigation, swimming and industrial needs. A database of 660 measurements for 13 parameters concentrations used, were taken from 11 monitoring points distributed along the Orontes River for a period of five years from 2015-2019, and to study the correlation between parameters and their impact on water quality, statistical analysis was applied using (SPSS) program. Cluster analysis was applied in order to classify the pollution areas along the river, and two groups were given: (low pollution - high pollution), where the areas were classified according to the sources of pollution to w

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Mon Oct 03 2016
Journal Name
International Journal Of Civil Engineering
Development of Excess Pore Water Pressure around Piles Excited by Pure Vertical Vibration
...Show More Authors

View Publication
Scopus (18)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Mon Dec 03 2018
Journal Name
Journal Of Engineering
Studying the Effects of Different Polymers on Rheological Properties of Water Base Muds
...Show More Authors

This research is focusing on finding more effective polymers that leads to enhance the rheological properties of Water Base Muds. The experiments are done for different types of mud for all substances which are Polyacrylamide, Xanthan gum, CMC (Carboxyl Methyl Cellulose). This study shows the effect of add polymer to red bentonite mud, effect of add polymer to Iraqi bentonite mud, the effect of add bentonite to polymer mud. The mud properties of Iraqi bentonite blank are enhanced after adding the polymers to the blank mix, CMC gives the highest value of plastic viscosity and Gel strength than others; X-anthan gives the highest value of yield point and gel strength than others. For the red bentonite mud, Polyacrylamide ha

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon May 01 2023
Journal Name
Journal Of Engineering
Experimental Evaluation of PV Panel Efficiency Using Evaporative Cooling Integrated with Water Spraying
...Show More Authors

In this work, an inventive photovoltaic evaporative cooling (PV/EC) hybrid system was constructed and experimentally investigated. The PV/EC hybrid system has the prosperous advantage of producing electrical energy and cooling the PV panel besides providing cooled-humid air. Two cooling techniques were utilized: backside evaporative cooling (case #1) and combined backside evaporative cooling with a front-side water spray technique (case #2). The water spraying on the front side of the PV panel is intermittent to minimize water and power consumption depending on the PV panel temperature. In addition, two pad thicknesses of 5 cm and 10 cm were investigated at three different water flow rates of 1, 2, and 3 lpm. In Case #1,

... Show More
View Publication Preview PDF
Crossref (7)
Crossref