New evidence on nanotechnology has shown interest in the creation and assessment of nanoparticles for cancer treatment. Worldwide, a wide range of tumor-targeted approaches are being developed to reduce side effects and boost the efficacy of cancer therapy. One strategy that shows promise is the use of metallic nanoparticles to increase the radio sensitization of the cancer cells while reducing or maintaining the normal tissue complication probability during radiation therapy. In this study, atmospheric plasma was created using argon gas to create Au NPs using the plasma jet scheme, and their ability to induce apoptosis as an anticancer mechanism was tested. Aqueous gold tetrachloride salts (HAuCl4·3H2O) ere used to produce gold nanoparticles. For conformations, various techniques were used to explore the characterization of Au NPs, included UV–Vis spectroscopy, X-Ray Diffraction (XRD), Field Emission Scanning Electron Microscopy (FE-SEM),). UV–vis spectroscopy showed a maximum absorption peak located between 520 and 530 nm. The peaks of XRD 2θ are observed at 38.8°, 44.47°, 64.4° and 77.17°. They correspond to the 111, 200, 220 and 311 crystalline levels respectively. The peak intensity (111) at 38.8° diffraction was maximum peak. the image of FESEM showed that the Au NPs which produced are irregularly shaped spheres with sizes ranging between 41-46 nm. The effect of nanoparticles on REF normal cell lines was studied to calculate cytotoxicity and the greatest rate of destruction of REF normal cell lines was 22.667% after incubation time 72 hour after exposure to the combination of irradiated gold nanoparticles-cisplatin with 50 Gray photon X-ray and 1 µg of cisplatin and the minimum was 0.7% after incubation time 24 hour after exposure to the combination of irradiated gold nanoparticles-cisplatin with 0.5 Gray photon x-ray and 0.025 µg of cisplatin. Its possible to enhance chemotherapy treatment by these nanoparticles, In the future these techniques will be possible to use for kill cancer cells, especially after showed low toxicity on normal cells.
Irinotecan (CPT-11) is a semisynthetic derivative of the antineoplastic agent camptothecin used in a wide range as an anti-cancer agent in many solid tumors because of its cytotoxic effect through the interaction with the topoisomerase I enzyme. The major limiting factors for irinotecan treatment are its association with potentially life-threatening toxicities including neutropenia and acute or delayed-type diarrhea, results from distinct interindividual and interethnic variability due to gene polymorphism.
This is a cross sectional pharmacogentics study was conducted on 25 cancer patients to estimate the prevalence of UGT1A1*93 and ABCC5 allele single nucleotide polymorphism (SNP) in Iraqi cancer patients treated with irinotecan
... Show MorePurpose/ to build clear perceptions about the level of the effects of organizational failures on the competitiveness of dairy factories and the role of dynamic knowledge capabilities in minimizing these impacts
Mythology/ Design approach Use deduction approach, the research was conducted in four dairy factories in Baghdad (Abu Ghraib, Agriculture, Halal and Ayon Al-Rafidain). It was applied to a sample of (155) individuals representing a sample of the research community from factory owners, managers, Engineers, technicians and experienced workers in the dairy industry. The questionnaire was used as a main tool for collecting data, information and statistical tools in the extraction, testing and analysis o
... Show MoreIt was rumored in the grammatical circles that the (short) refrigerant is only a copy of (book) Sibweh, except some of the views that violated it, or some of the evidence that increased it; On the (brief) or not, the researcher has chosen the subject (what is going away and not leave) a field of study of the budget, has come on three demands, the first devoted to the study of the term, and the second to explain the methodology of scientists in the presentation of the topic, and the third was limited to the study of the evidence they invoked .
God grants success
The ring modulator described in part I of this paper is designed here for two operating wavelengths 1550nm and 1310nm. For each wavelength, three structures are designed corresponding to three values of polymer slot widths (40, 50 and 60nm). The performance of these modulators are simulated using COMSOL software (version 4.3b) and the results are discussed and compared with theoretical predictions. The performance of intensity modulation/direct detection short range and long rang optical communication systems incorporating the designed modulators is simulated for 40 and 100Gb/s data rates using Optisystem software (version 12). The results reveal that an average energy per bit as low as 0.05fJ can be obtained when the 1550nm modulator is d
... Show MoreSimultaneous determination of Furosemide, Carbamazepine, Diazepam, and Carvedilol in bulk and pharmaceutical formulation using the partial least squares regression (PLS-1 and PLS-2) is described in this study. The two methods were successfully applied to estimate the four drugs in their quaternary mixture using UV spectral data of 84synthetic mixtures in the range of 200-350nm with the intervals Δλ=0.5nm. The linear concentration range were 1-20 μg.mL-1 for all, with correlation coefficient (R2) and root mean squares error for the calibration (RMSE) for FURO, CARB, DIAZ, and CARV were 0.9996, 0.9998, 0.9997, 0.9997, and 0.1128, 0.1292, 0.1868,0.1562 respectively for PLS-1, and for PLS-2 were 0.9995, 0.9999, 0.9997, 0.9998, and 0.1127, 0.
... Show MoreAbstract :In this study, amygdaline in Iraqi plant seeds was extracted and isolated from their seeds matrix using reflux procedure and subsequently identified and determined by high performance liquid chromatography (HPLC) on reversed phase column of LC-18 (150mm x 4.6mm, 5?m )with actonitrile :water ( 50 : 50 ) as mobile phase at flow rate of ( 0.5 mL/min ) and detection at wavelength of 215 nm.The experimental results indicated that the linearity of calibration is in the range of 1.0-30.0 mg L-1amygdaline with the correlation coefficient of 0.9949. The limit of detection (LOD) and limit of quantitation (LOQ) for amygdaline were of 0.88 and 2.93 mg L-1 in standard pure sample. The mean recovery percent is 97.34±0.58 at 95% confidence inte
... Show Moreالمواقف افي الدول العربية قراءة تحليلية في مواقف لدولية من التغيير (الولايات المتحدة - الاتحاد الاوروبي - روسيا)