Background: Echocardiography has an important role to follow up patients with Iatrogenic atrial septaldefect (IASD) and after Catheter ablation during electro-physiological study.Objectives: evaluating the impact of non-invasive Transthoracic Echocardiography (TTE) parameters(LAVI, LVEF, ASD size and E/e`) post radiofrequency ablation of left atrial arrhythmia.Patients and methods: for the evaluation of the atrial septal defect, a transthoracic echocardiography(TTE) was used in patients who underwent left atrial arrhythmia ablation, enrolled in prospective studyin the Iraqi center for cardiac diseases, in cooperation with university of Baghdad /college of medicineResults: The outcomes of the present study were assessed according to Transthoracic Echocardiographicparameters with a median period of follow up of six months post-radiofrequency procedure for eachpatient. The mean of age was (36.28±10.34 years), females were 24 (51.1%) while males were 23(48.9%), with no structured heart diseases and normal LV function with mean EF (64.68± ,5.23%) andthe mean LA diameter (35.75±,2.92mm). Iatrogenic atrial septal defects (IASDs) were detected by TTEin all patients with range from (2-5) mm with mean of (3.47±0.92). Also we noticed that patients withsmaller ASD size had higher LVEF than those who had larger ASD size with (P=0.007), while there wasno significant association between ASD size with left atrial volume index (LAVI) and E/e`.Conclusions: Non-invasive Transthoracic Echocardiography (TTE) study that was used post atrialseptostomy for monitoring the closure of residual atrial septal defect is useful and applicable. And maybe used in daily practise post atrial septostomy procedure and recommended rather than the use ofinvasive Transoesophageal Echocardiography (TEE).
A new, simple and sensitive method was used forevaluation of propranolol withphosphotungstic acidto prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on reaction between propranolol and phosphotungstic acid in an aqueous medium to obtain a yellow precipitate. Optimum parameters was studied to increase the sensitivity for developed method. A linear range for calibration graph was 0.007-13 mmol/L for cell A and 5-15 mmol/L for cell B, and LOD 207.4792 ng/160 µL and 1.2449 µg/160 µL respectively to cell A and cell B with correlation coefficient (r) 0.9988 for cell A, 0.9996 for cell B, RSD% was lower than 1%, (n=8) for the
... Show MoreEstimation of the unknown parameters in 2-D sinusoidal signal model can be considered as important and difficult problem. Due to the difficulty to find estimate of all the parameters of this type of models at the same time, we propose sequential non-liner least squares method and sequential robust M method after their development through the use of sequential approach in the estimate suggested by Prasad et al to estimate unknown frequencies and amplitudes for the 2-D sinusoidal compounds but depending on Downhill Simplex Algorithm in solving non-linear equations for the purpose of obtaining non-linear parameters estimation which represents frequencies and then use of least squares formula to estimate
... Show MoreThe H-Point Standard Addition Method (H-PSAM) has been applied for spectrophotometric simultaneous determination of Cimetidine and Erythromycin ethylsuccinate using Bromothymol Blue (BTB) as a chromogenic complexing agent in a buffer solution at pH 5.5.
Traumatic radial nerve injury in humeral shaft fracture is the most common traumatic nerve injury in long-bone fracture, with overall prevalence 2-18%, ranging from traction to complete transection. Spontaneous recovery may reach 88%. The aim of the study is to assess the sensitivity & specificity of the ultrasound to detect the radial nerve injury and to see if this can be used as a diagnostic test. This is a prospective study on 17 adult patients with a closed fracture of the humeral shaft, dividing into two groups, the first group of 7 patients had signs and symptoms of radial nerve palsy at presentation and the second group of 10 patients had intact radial nerve function was considered as a control group. All these patients had at leas
... Show MoreRuthenium-Ruthenium and Ruthenium–ligand interactions in the triruthenium "[Ru3(μ-H)(μ3-κ2-Hamphox-N,N)(CO)9]" cluster are studied at DFT level of theory. The topological indices are evaluated in term of QTAIM (quantum theory of atoms in molecule). The computed topological parameters are in agreement with related transition metal complexes documented in the research papers. The QTAIM analysis of the bridged core part, i.e., Ru3H, analysis shows that there is no bond path and bond critical point (chemical bonding) between Ru(2) and Ru(3). Nevertheless, a non-negligible delocalization index for this non-bonding interaction is calculated
... Show MoreDensity Functional Theory (DFT) method of the type (B3LYP) and a Gaussian basis set (6-311G) were applied for calculating the vibration frequencies and absorption intensities for normal coordinates (3N-6) at the equilibrium geometry of the Di and Tetra-rings layer (6, 0) zigzag single wall carbon nanotubes (SWCNTs) by using Gaussian-09 program. Both were found to have the same symmetry of D6d point group with C--C bond alternation in all tube rings (for axial bonds, which are the vertical C--Ca bonds in rings layer and for circumferential bonds C—Cc in the outer and mid rings bonds). Assignments of the modes of vibration IR active and inactive vibration frequ
... Show MoreThe preparation and characterization of innovative nanocomposites based on zinc oxide nanorods (ZNR) encapsulated by graphene (Gr) nanosheets and decorated with silver (Ag), and cupper (Cu) nanoparticles (NP) were studied. The prepared nanocomposites (ZNR@Gr/Cu-Ag) were examined by different techniques including Field Emission Scanning Electron Microscope (FESEM), Transmission electron microscopy (TEM), Atomic force microscopy (AFM), UV-Vis spectrophotometer and fluorescence spectroscopy. The results showed that the ZNR has been good cover by five layers of graphene and decorated with Ag and Cu NPs with particles size of about 10-15 nm. The ZNR@Gr/Cu-Ag nanocomposites exhibit high absorption behavior in ultraviolet (UV) region of sp
... Show Morerhabditid Mesorhabditis franseni Fuchs, 1933 (Family, Mesorhabditidae) and pratylenchid nematode Pratylenchus goodeyi Sher and Allen, 1953 (Family, Pratylenchidae). They were illustrated by molecular aspects. All specimens of both genera were cultured and reproduced for DNA extraction. M. franseni (IRQ.ZAh2 PP528819.1 isolate) was characterized. P. goodeyi (IRQ.ZAh5 PP535537 isolate) was also characterized. Selected specimens of these two species were molecularly characterized using the partial ITS-rRNA gene sequences. The ITS-rRNA sequence of IRQ.ZAh2 PP528819.1 isolate had a range of (98.62%-100%) sequence homology with ITS-rRNA sequence of M. franseni available in NCBI database. While, the ITS-rRNA sequence of IRQ.ZAh5 PP535537 isolate h
... Show MoreThe removal of heavy metal ions from wastewater by ion exchange resins ( zeolite and purolite C105), was investigated. The adsorption process, which is pH dependent, shows maximum removal of metal ions at pH 6 and 7 for zeolite and purolite C105 for initial metal ion
concentrations of 50-250 mg/l, with resin dose of 0.25-3 g. The maximum ion exchange capacity was found to be 9.74, 9.23 and 9.71 mg/g for Cu2+, Pb2+, and Ni2+ on zeolite respectively, while on purolite C105 the maximum ion exchange capacity was found to be 9.64 ,8.73 and 9.39 for Cu2+, Pb2+, and Ni2+ respectively. The maximum removal was 97-98% for Cu2+ and Ni2+ and 92- 93% for Pb2+ on zeolite, while it was 93-94% for Cu2+, 96-97% for Ni2+, and 87-88% for Pb2+ on puroli