Preferred Language
Articles
/
ohb1UYoBVTCNdQwCRpQe
Design of a Fractional Order Sliding Mode Controller for Twin Rotor Aerodynamic System
...Show More Authors

This paper proposes a new structure for a Fractional Order Sliding Mode Controller (FOSMC) to control a Twin Rotor Aerodynamic System (TRAS). The new structure is composed by defining two 3-dimensional sliding mode surfaces for the TRAS model and introducing fractional order derivative integral in the state variables as well as in the control action. The parameters of the controller are determined so as to minimize the Integral of Time multiplied by Absolute Error (ITAE) performance index. Through comparison, this controller outperforms its integer counterpart in many specifications, such as reducing the delay time, rise time, percentage overshoot, settling time, time to reach the sliding surface, and amplitude of chattering in control input.

Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
The study of thermal description for non-thermal plasma needle system
...Show More Authors

Cold plasma is a relatively low temperature gas, so this feature enables us to use cold plasma to treat thermally sensitive materials including polymers and biologic tissues. In this research, the non-thermal plasma system is designed with diameter (3 mm, 10 mm) Argon at atmospheric pressure as well as to be suitable for use in medical and biotechnological applications.
The thermal description of this system was studied and we observed the effect of the diameter of the plasma needle on the plasma, when the plasma needle slot is increased the plasma temperature decrease, as well as the effect of the voltages applied to the temperature of the plasma, where the temperature increasing with increasing the applied voltage . Results showed t

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Determination of solar window for Baghdad city using pv system program
...Show More Authors

Been using a pv system program to determine the solar window for Baghdad city . the solar window for any location can be determine by deviating left and right from the geographical south as well as deviation according to the amount of tilt angle with the horizon for fixed panel so that will not change the average of solar radiation incident over the whole year and this lead to help in the process of installation of fixed solar panel without any effect on annual output .the range of solar window for Baghdad city between two angles ( -8 - +8 ) degrees left to right of the geographical south and tilt angle that allowed for the horizon range between angles (21- 30) degrees so that the amount of solar radiation that falling on the solar pan

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 07 2018
Journal Name
International Journal Of Applied Pharmaceutics
FORMULATION AND CHARACTERIZATION OF LAFUTIDINE NANOSUSPENSION FOR ORAL DRUG DELIVERY SYSTEM
...Show More Authors

Objective: The objective of this study was to prepare nanosuspension of a practical water insoluble antiulcer drug which is lafutidine to enhance the solubility, dissolution rate with studying the effect of different formulation variables to obtain the best formula with appropriate physical properties and higher dissolution rate.Methods: Nanosuspension of lafutidine was prepared using solvent anti-solvent precipitation method using Polyvinylpyrrolidone K-90(PVP K-90) as the stabilizer. Ten formulations were prepared to show the effect of different variables in which two formulations showed the effect of stabilizer type, three formulations showed the effect of stabilizer concentration, two formulations showed the effect of combinatio

... Show More
View Publication
Scopus (27)
Crossref (14)
Scopus Crossref
Publication Date
Fri Dec 07 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Novel Combination for Self-Nanoemulsifying Drug Delivery System of Candesartan Cilexetil
...Show More Authors

Solubility problem of many of effective pharmaceutical molecules are still one of the major obstacle in theformulation of such molecules. Candesartan cilexetil (CC) is angiotensin II receptor antagonist with very low water solubility and this result in low and variable bioavailability. Self- emulsifying drug delivery system (SEDDS) showed promising result in overcoming solubility problem of many drug molecules. CC was prepared as SEDDS by using novel combination of two surfactants (tween 80 and cremophore EL) and tetraglycol as cosurfactant, in addition to the use of triacetin as oil. Different tests were performed in order to confirm the stability of the final product which includes thermodynamic study, determination of self-emulsificat

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (1)
Scopus Crossref
Publication Date
Fri May 03 2024
Journal Name
Journal Of Optics
Transmission Of 10 Gb/s For Underwater Optical Wireless Communication System
...Show More Authors

View Publication
Scopus (9)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
In Situ Gelling Formulation of Naproxen for Oral Sustained Delivery System
...Show More Authors

Naproxen is non-steroidal anti-inflammatory drug, which has antipyretic and anti-inflammatory effect. It is extensively bound to plasma albumin, and exhibits gastric toxicity, so it may be more efficient to deliver the drug in its sustained release dosage form and adequate blood level is achieved. Three liquid formulations with in situ gelling properties have been assessed for their potential for the oral sustained delivery of naproxen . The formulations were dilute solutions of: (a) pectin; (b) gellan gum and; (c) sodium alginate, all containing complexed calcium ion that form gels when these ions are released in the acidic environment of the stomach . The viscosity of the sols and drug release were measured, and was found to be depende

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Towards C+L Band Three-Mode (De)Multiplexer Using Subwavelength Grating (SWG) Technology
...Show More Authors

Abstract: Recently, there is increasing interest in using mode-division multipelexing (MDM) technique  to enhace  data rate transmission over multimode fibers.  In this technique, each fiber mode is treated as a separate optical carrier to transfer its own data.  This paper presents a broadband, compact, and low loss three-mode (de)multiplexer designed for C+L band using subwavelength grating (SWG) technology and built-in silicon-on-insulator SOI platform. SWG offers refractive index engineering for wider operating bandwidth and compact devices compared to conventional ones. The designed (de)multiplex deals with three modes (TE0, TE1, and TE2) and has a loss > -1 dB and crosstalk < −15 dB, and its operation c

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 01 2023
Journal Name
Results In Engineering
Low-cost autonomous car level 2: Design and implementation for conventional vehicles
...Show More Authors

View Publication
Scopus (32)
Crossref (32)
Scopus Clarivate Crossref
Publication Date
Wed Jun 06 2001
Journal Name
المجلة العراقية للعلوم الاحصائية
Suggest formulas for estimating carry-over effects in two-period changeover design
...Show More Authors

This research aims to suggest formulas to estimate carry-over effects with two-period change-over design, and then, all other effects in the analysis of variance of this design, and find the efficiency of the two-period change-over design relative to another design (say, completely randomized design).

Preview PDF
Publication Date
Tue Sep 21 2021
Journal Name
Jmerd
stress and strain analysis for the prosthetic hand design actuated by links
...Show More Authors

Prosthetic hands are compensatory devices for the hand amputees as a result of injury, various accidents or birth deformities, types of prosthetic hand vary depending on the mechanism they operate and how they perform. There are common types in use that are characterized by their complex mechanisms, which are difficult for the amputee to use or exclude use because of their high cost, therefore the aim of this research is to design an artificial hand that is suitable in terms of simplicity of use and low cost and similar to a natural hand with regard to dimensions and shape that operated in the mechanism of links. This research involves Stress and strain analysis of the prosthetic hand and its fingers that modelled from (Petg CR)

... Show More
View Publication Preview PDF