Preferred Language
Articles
/
oRd1oZIBVTCNdQwCILtA
Free radical scavenging activity of silibinin in nitrite-induced hemoglobin oxidation and membrane fragility models
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Thu May 01 2014
Journal Name
European Journal Of Pharmacology
The effects of different doses of silibinin in combination with methotrexate on testicular tissue of mice
...Show More Authors

Methotrexate (MTX) is widely used chemotherapeutic agent with different side effects including germ cells toxicities. Silibinin is one of the structural isomers of silymarin, with different phytotherapeutic applications, and its possible protective effects against MTX induced germ cells damage were investigated in this work. Twenty five male mice were divided into five groups (n=5) allocated as follows: Group 1 received buffer for five days given by single intraperitoneal (IP) injection per day; Group 2 in addition to buffer for five days, animals received at day five single dose of 20mg/kg of MTX IP. Groups (3, 4, and 5) received respectively, (50, 100, or 150mg/kg body weight) of silibinin IP single daily dose for five days then at day fi

... Show More
View Publication
Scopus (27)
Crossref (28)
Scopus Clarivate Crossref
Publication Date
Wed Apr 01 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Evaluation of some inflammatory cytokines and glycated hemoglobin in uncontrolled type 2 diabetes mellitus with nephropathy
...Show More Authors

Background: Chronic hyperglycemia causes diabetic nephropathy(DN), which is a typical microvascular complication of type 2 diabetes mellitus. The pathogenesis of DN is not fully understanding. The inflammation may possess a significant role in the progression of DN in diabetic patients. Method: The study accomplished at teaching laboratories of medical city, Baghdad, Iraq. It was included 50uncontrolled diabetic type 2 patients with nephropathy, age range (40-78) years and 42 controlled diabetics type 2 without nephropathy, age range (35 - 52) years as a control group. The participants divided in to two groups according to HbA1c measurement which is described as follows: < 7.5% of HbA1c describes controlled diabetes, and > 9% of HbA1c

... Show More
Scopus (9)
Scopus
Publication Date
Sun Sep 01 2019
Journal Name
Indian Journal Of Public Health Research & Development
Effect of Thyroid Hormone Abnormalities on Hemoglobin A1c in Hemodialysis Patients Taking Erythropoietin
...Show More Authors

Background: Hemoglobin A1c (HbA1c) is a widely used test for glycemic control. It is done for chronic kidney disease (CKD) patients. Renal disease is accompanied by thyroid abnormalities, which affect HbA1c, especially in those taking erythropoiesis-stimulating agents (ESAs). We aimed to find the effect of thyroid dysfunction on HbA1c in hemodialysis patients taking ESAs and those who do not. Materials and Method: Fifty six patients were included in this study, which was done between September 2017 and June 2018, in Baghdad Teaching Hospital. Thyroid stimulating hormone, free T3, free T4 and HbA1c measurements were done. The patients were divided into 2 groups; those who took ESAs and those who did not, then they were subdivided into those

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Indian Journal Of Public Health Research &amp; Development
Effect of Thyroid Hormone Abnormalities on Hemoglobin A1c in Hemodialysis Patients Taking Erythropoietin
...Show More Authors

Abstract Background Hemoglobin A1c (HbA1c) is a widely used test for glycemic control. It is done for chronic kidney disease (CKD) patients. Renal disease is accompanied by thyroid abnormalities, which affect HbA1c, especially in those taking erythropoiesis-stimulating agents (ESAs). We aimed to find the effect of thyroid dysfunction on HbA1c in hemodialysis patients taking ESAs and those who do not. Materials and Method Fifty six patients were included in this study, which was done between September 2017 and June 2018, in Baghdad Teaching Hospital. Thyroid stimulating hormone, free T3, free T4 and HbA1c measurements were done. The patients were divided into 2 groups; those who took ESAs and those who did not, then they were subdivided into

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
The Correlation between Serum Total Adiponectin and Hemoglobin in Type 2 Diabetic Patients without Microalbuminuria
...Show More Authors

Low serum total adiponectin is associated with a high incidence of type 2 diabetes or coronary artery disease in the general population. Paradoxically, serum total adiponectin is elevated in patients with chronic kidney disease (CKD), such as overt diabetic nephropathy. The current study aimed to investigate whether or not  anemia to be dependently associated with serum level of total adiponectin in  non-albuminuric male patients with type 2 diabetes . The study included 42 type 2 diabetic male patients. Anemia was defined as hemoglobin (Hb) below 14.0g/dL. All the patients were without microalbuminuria, to exclude diabetic nephropathy. The diabetic patients were divided into 2 groups according to the hemoglobin level in ad

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Aug 29 2018
Journal Name
Journal Of Engineering
Zeta Potential, Effective Membrane Charge and Donnan Potential for TiO2 NF Ceramic Membrane
...Show More Authors

Nanofiltration (NF) ceramic membrane have found increasing applications particularly in wastewater and water treatment. In order to estimate and optimize the performance of NF membranes, the membrane should be characterized correctly in terms of their basic parameters such as effective pore radius (rp) and equivalent effective thickness as well as effective surface charge ( ), the effective charge density ( ) and Donnan potential ( ). The impact of electrokinetic (zeta) potential on the membrane surface charge density, effective membrane charge density and Donnan potential at two different concentrations of the reference solutions 0.001, 0.01 M sodium chloride at various pH values from 3 to 9, and effective po

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sun Sep 30 2012
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Polyvinyl Alcohol – Sodium Nitrite Water Soluble Composite as a Corrosion Inhibitor for Mild Steel in Simulated Cooling Water
...Show More Authors

The inhibitive action of polyvinyl alcohol –sodium nitrite (PVASN) composite on the corrosion of mild steel in simulated cooling water (SCW) has been investigated by weight loss and potentiodynamic polarization. The effect of composite concentration (PVA/SN) , pH, and exposure time on corrosion rate of mild steel were verified using 2 levels factorial design and surface response analysis through weight loss approach, while the electrochemical measurements were used to study the behavior of mild steel in (SCW) with pH between 6 and 8 and in absence and presence of (PVA) in solution containing different concentration of NaNO2. It was verified that all three main variables studied were statistically significant while their interaction is

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 01 2022
Journal Name
Baghdad Science Journal
Effect of Alstonia Boonei Stem Bark Extracts on the Activity of Liver Maker Enzymes in Rats Induced by Ccl4
...Show More Authors

This study investigated the outcome of Alstonia boonei stem bark on liver enzymes after inducing the Wistar albino rats with carbon tetrachloride (CCl4). This effect of plant extract was compared with silymarin – a drug commonly used for the treatment of chronic hepatocyte disorder. The plant sample was extracted with ethanol; acute toxicity study of the extract was performed on eighteen Wistar mice, while 30 rats were sacrificed for liver enzymes assay. The rats were divided into six clusters: each cluster has five rats, culster 1 served as control and was given 2 mL/kg b.w - distilled water; clusters 2 – 6 were CCl4 induced. Cluster 2 was untreated but served as the negative control while cluster 3 wa

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Sat Dec 11 2021
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Association of Age, Parity and Body mass Index with Hemoglobin and Serum Ferritin Levels in Pregnant Women in Baghdad City
...Show More Authors

Hemogloin (Hb) and serum ferritin levels are used to assess anemia in pregnancy. Some studies referred to the influence of maternal age, body mass index (BMI) and parity on Hb and serum ferritin levels. The study aimed to examine the possible association of maternal Hb and serum ferritin with maternal age, parity, and BMI in a sample of pregnant women in Baghdad.

 Ninety healthy pregnant women, grouped in three equal groups according to the pregnancy trimester, and thirty apparently healthy non-pregnant women from Baghdad were enrolled in this observational study.  Blood and serum samples were obtained for the estimation of Hb and serum ferritin levels.

The pooled data of participants showed a n

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Iraqi Journal Of Science
Paper based glucose biosensor depending on SPCE modified with hemoglobin and silver nanoparticles
...Show More Authors

The direct electron transfer behavior of hemoglobin that is immobilized onto screen-printed carbon electrode (SPCE) modified with silver nanoparticles (AgNPs) and chitosan (CS) was studied in this work. Cyclic voltametry and spectrophotometry were used to characterize the hemoglobin (Hb) bioconjunction with AgNPs and CS. Results of the modified electrode showed quasi-reversible redox peaks with a formal potential of (-0.245 V) versus Ag/AgCl in 0.1 M phosphate buffer solution (PBS), pH7, at a scan rate of 0.1 Vs-1. The charge transfer coefficient (α) was 0.48 and the apparent electron transfer rate constant (Ks) was 0.47 s-1. The electrode was used as a hydrogen peroxide biosensor with a linear response over 3 to 240 µM and a detection li

... Show More
Scopus