Preferred Language
Articles
/
oBYiTocBVTCNdQwC5EO0
Does Mixed Conventional/Piezosurgery Implant Site Preparation Affect Implant Stability?
...Show More Authors

The aim of this study was to compare the effect of conventional implant site preparation technique and a combination of conventional/piezosurgery preparation on implant stability measured at different time intervals, insertion torque, and preparation time. A randomized controlled study was designed, it included 26 patients who received 54 dental implants randomly assigned to 2 groups; in the control group, implants were installed after conventional preparation with drills whereas the study group received implants after mixed conventional/piezosurgery preparation. The outcome variables included: implant stability measured immediately after implant insertion, at 8 weeks and 16 weeks postoperatively, insertion torque and preparation time. All the investigated variables were analyzed statistically using 1 sample Kolmogrov-Simirenov test, Mann-Whitney U test, paired and unpaired Student t test, the Pearson χ test, Fisher exact test, and analysis of variance (1-way ANOVA). The differences were considered significant at P ≤ 0.05. Implant stability showed a similar pattern in both the groups which consists of a statistically significant decrease in implant stability quotient values at the 8th week followed by a statistically significant increase at the 16th week, where the implant stability quotient values return close to those of primary stability. The 2 groups revealed a statistically not significant difference in insertion torque and implant stability changes throughout the study period, whereas the preparation time was significantly longer in the study group than the control group. The mixed conventional/piezosurgery method of implant site preparation offers no additional advantage over the conventional drilling method in terms of values of insertion torque and patterns of implant stability change throughout the healing period.

Scopus Clarivate Crossref
View Publication
Publication Date
Thu Sep 18 2014
Journal Name
Journal Of Chemical And Pharmaceutical Research
Preparation, characterization, and antibacterial properties of mixed ligand complexes of L-aspargine and sulfamethoxazole(antibiotic) with Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Hg(II) ions
...Show More Authors

The research includes the synthesis and identification of the mixed ligands complexes of M+2ions in general composition[M(Asn)2(SMX)] Where L- Aspargine (C4H8N2O3)symbolized (AsnH) as a primary ligand and Sulfamethoxazole(C10H11N3O3S) symbolized (SMX) as a secondary ligand. The ligands and the metal chlorides were brought in to reaction at room temperature in(v/v) ethanol /water as solvent containing NaOH. The reaction required the following [(metal: 2(Na+Asn-): (SMX)] molar ratios with M(II) ions, Where: M(II)=Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Hg(II). The UV–Vis and magnetic moment data revealed an octahedral geometry around M(II), The conductivity data show a non-electrolytic nature of the complexes. The antimicrobial a

... Show More
Publication Date
Tue Dec 11 2018
Journal Name
Baghdad Science Journal
Thermoluminescence dosimetry of mixed neutron – gamma fields
...Show More Authors

The method of measurement dosimetry in neutron – gamma field by using CaSo4 : Dy (PTFE) disc which has a diameter of 1.3mm and thickness of 0.2mm and using hydrogenated material as a converters of neutron to recoil protons (n-p) reaction, the discs were irradiated by neutron source (241Am-Be) with flux of 4.5?105 n/cm2s for different time to obtain different dose. The TL signals, which we have been obtained by using the converters, are increases to 71%. So we can resolve the neutron and gamma in mixed field.

View Publication Preview PDF
Crossref
Publication Date
Fri Jun 25 2021
Journal Name
International Journal Of Drug Delivery Technology
Mixed Ligand Complexes of Trimethoprim: A Review
...Show More Authors

In this research, we highlight the most important research related to the mixed ligand complexes of the drug trimethoprim (TMP), and for the past 7 years where this drug has been used as a chelating ligand and gives stability to the complexes with ions of metal elements where these complexes, prepared and diagnosed, and for some research the bacterial activity was studied against different types of bacteria

View Publication
Scopus (1)
Scopus
Publication Date
Wed Jun 02 2021
Journal Name
International Journal Of Drug Delivery Technology
Mixed Ligand Complexes of Trimethoprim: A Review
...Show More Authors

In this research, we highlight the most important research related to the mixed ligand complexes of the drug trimethoprim (TMP), and for the past 7 years where this drug has been used as a chelating ligand and gives stability to the complexes with ions of metal elements where these complexes, prepared and diagnosed, and for some research the bacterial activity was studied against different types of bacteria.

Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
Bulletin Of Mathematics And Statistics Research
New Approximation Operators Using Mixed Degree Systems
...Show More Authors

This paper is concerned with introducing and studying the first new approximation operators using mixed degree system and second new approximation operators using mixed degree system which are the core concept in this paper. In addition, the approximations of graphs using the operators first lower and first upper are accurate then the approximations obtained by using the operators second lower and second upper sincefirst accuracy less then second accuracy. For this reason, we study in detail the properties of second lower and second upper in this paper. Furthermore, we summarize the results for the properties of approximation operators second lower and second upper when the graph G is arbitrary, serial 1, serial 2, reflexive, symmetric, tra

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 05 2023
Journal Name
Journal Of Engineering
Isolated Word Speech Recognition Using Mixed Transform
...Show More Authors

Methods of speech recognition have been the subject of several studies over the past decade. Speech recognition has been one of the most exciting areas of the signal processing. Mixed transform is a useful tool for speech signal processing; it is developed for its abilities of improvement in feature extraction. Speech recognition includes three important stages, preprocessing, feature extraction, and classification. Recognition accuracy is so affected by the features extraction stage; therefore different models of mixed transform for feature extraction were proposed. The properties of the recorded isolated word will be 1-D, which achieve the conversion of each 1-D word into a 2-D form. The second step of the word recognizer requires, the

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Nov 12 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of en-masse retraction using microimplant versus conventional techniques: An in vitro study
...Show More Authors

Background: The study aimed to investigate the effect of different techniques of en masse retraction on the vertical and sagittal position, axial inclination, rate of space closure, and type of movement of maxillary central incisor. Materials and methods: A typodont simulation system was used (CL II division 2 malocclusion). Three groups were used group 1(N=10, T-loop), group 2(N=10, Time-Saving loop), and group 3(N=10, Microimplant). Photographs were taken before and after retraction and measurements were made using Autodesk AutoCAD© software 2010. Kruskal-Wallis one-way analyses of variance and Mann-Whitney U test (p?0.05) were used. Results: The rate of space closure showed no significant difference among the three groups (p?0.05), whi

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 27 2018
Journal Name
Iraqi Journal Of Laser
Investigation of Densified SiO2 Sol-Gel Thin Films Using Conventional and DPSS Laser Techniques
...Show More Authors

The prepared nanostructure SiO2 thin films were densified by two techniques (conventional and Diode Pumped Solid State Laser (DPSS) (532 nm). X-ray diffraction (XRD), Field Emission Scanning electron microscopy (FESEM), and Atomic Force Microscope (AFM) technique were used to analyze the samples. XRD results showed that the structure of SiO2 thin films was amorphous for both Oven and Laser densification. FESEM and AFM images revealed that the shape of nano silica is spherical and the particle size is in nano range. The small particle size of SiO2 thin film densified by DPSS Laser was (26 nm) , while the smallest particle size of SiO2 thin film densified by Oven was (111 nm).

View Publication Preview PDF
Publication Date
Sun Dec 30 2012
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Estimation of the Rock Mechanical Properties Using Conventional Log Data in North Rumaila Field
...Show More Authors

Hydrocarbon production might cause changes in dynamic reservoir properties. Thus the consideration of the mechanical stability of a formation under different conditions of drilling or production is a very important issue, and basic mechanical properties of the formation should be determined.
There is considerable evidence, gathered from laboratory measurements in the field of Rock Mechanics, showing a good correlation between intrinsic rock strength and the dynamic elastic constant determined from sonic-velocity and density measurements.
The values of the mechanical properties determined from log data, such as the dynamic elastic constants derived from the measurement of the elastic wave velocities in the material, should be more a

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 31 2016
Journal Name
Al-kindy College Medical Journal
Comparison between Open Mini-incision Thyroidectomy and Conventional Thyroidectomy: Clinical Experience and Literatures Review
...Show More Authors

Background: Thyroid surgery is most common endocrine surgery in general surgical practice. Objectives: the aim of this work is to evaluate the feasibility, benefits and outcomes of open mini-incision thyroidectomy and compared the results with that of conventional thyroidectomy. The comparison between the two groups was in term of incision length, amount of blood loss, time of operation, postoperative pain, hospital stay and the cosmetic outcomes.Type of the study: this is a single-blinded randomized controlled studyMethods: This study compared the advantages and outcomes of 22 patients subjected to mini-incision thyroidectomy (Group A) with the equal numbers of patients subjected to conventional thyroidectomy (Group B).Results: the oper

... Show More
View Publication Preview PDF