An electrochemical sensor based on an amino-functionalized iron NH2-MIL-101(Fe) metal-organic framework (MOF)/Pd nanoparticles (NPs) composite-modified screen-printed electrode (SPE) is prepared for the simultaneous determination of norepinephrine (NEPI) and acetaminophen (ACP). The NH2-MIL-101(Fe) MOF/Pd NPs/SPE electrochemical sensor shows a significant enhancement in the response peak current of NEPI, as compared to bare SPE. This suggests that the unique features of NH2-MIL-101(Fe) MOF/Pd NPs composite-modified SPE improve the electrocatalytic oxidation of NEPI. Such a synergistic effect between NH2-MIL-101(Fe) MOF and Pd NPs results in a significant enhancement in the response, where the MOF's high surface area combines with the high electron-transfer rate and the abundance of catalytically active sites afforded by the Pd NPs. The differential pulse voltammetry (DPV) method was obtained for quantitative determination of NEPI and high sensitivity was observed in NEPI determination with the calibration slope of 0.0327, µA µM-1. The developed NH2-MIL-101(Fe) MOF/Pd NPs/SPE sensor presents a low limit of detection of 0.007 µM toward NEPI determination. The developed NH2-MIL-101(Fe) MOF/Pd NPs/SPE sensor shows a good catalytic activity for the oxidation of NEPI and ACP, with anodic peak potentials of 360 and 550 mV, respectively. The separation of anodic peak potential is sufficient to enable simultaneous determination. Finally, the suggested sensing platform has confirmed suitable for the simultaneous determination of NEPI and ACP in real samples (pharmaceutical formulations and urine samples), achieving recovery values ranging from 97.1 to 104.4 % with relative standard deviations ≤3.6 %.
The downhole flow profiles of the wells with single production tubes and mixed flow from more than one layer can be complicated, making it challenging to obtain the average pressure of each layer independently. Production log data can be used to monitor the impacts of pressure depletion over time and to determine average pressure with the use of Selective Inflow Performance (SIP). The SIP technique provides a method of determining the steady state of inflow relationship for each individual layer. The well flows at different stabilized surface rates, and for each rate, a production log is run throughout the producing interval to record both downhole flow rates and flowing pressure. PVT data can be used to convert measured in-situ rates
... Show MoreIn this paper, effective slab width for the composite beams is investigated with special emphasis on the effect of web openings. A three dimensional finite element analysis, by using finite element code ANSYS, is employed to investigate shear lag phenomenon and the resulting effective slab width adopted in the classical T-beam approach. According to case studies and comparison with limitations and rules stipulated by different standards and codes of practice it is found that web openings presence and panel proportion are the most critical factors affecting effective slab width, whereas concrete slab thickness and steel beam depth are less significant. The presence of web opening reduces effective slab width by about 21%.
... Show More The current research is interested in the objective study of revitalizing the religious sites and the extent to which they achieve the pragmatic and semantic ends, because they are derived from history and civilization and have a clear impact over the recipient. The research question is (what are the techniques of developing the spaces of the religious shrines in accordance with revitalizing the interior spaces within them?).
The research aims at determining the weak and strong points in the process of revitalizing the interior spaces in the religious shrines.
The theoretical framework consists of two parts: the first addressed the revitalization in the interior design, and the second addressed the religious shrines and th
Objectives: To assess pregnant women’s knowledge regarding syphilisand to find out the relationship between women’s knowledge regarding syphilis infection and demographic and reproductive variables. Methodology: A descriptive analytical study of non probable (purposive sample) of 250 pregnant women during their different gestational ages for the period (October 2nd to April 25th 2013) by using questionnaire format consists of demographic variables and items of women's knowledge regarding syphilis who are visiting primary health care centers in Al-Kharkh and Al-Rrusafa in Baghdad city. The coefficient relia
The load shedding scheme has been extensively implemented as a fast solution for unbalance conditions. Therefore, it's crucial to investigate supply-demand balancing in order to protect the network from collapsing and to sustain stability as possible, however its implementation is mostly undesirable. One of the solutions to minimize the amount of load shedding is the integration renewable energy resources, such as wind power, in the electric power generation could contribute significantly to minimizing power cuts as it is ability to positively improving the stability of the electric grid. In this paper propose a method for shedding the load base on the priority demands with incorporating the wind po
... Show MoreObjective: Pregnancy-induced hypertension (PIH) is a major pregnancy complication that leads to maternal mortality. Here, we have scrutinized the correlation between serum levels of hydrogen peroxide (H2O2) and superoxide dismutase (SOD) in PIH.Methods: Serum samples were collected from 80 Iraqi women (40 women with PIH as patients group, 20 normotensive pregnant women as a positive control, and 20 normotensive non-pregnant women as a negative control) all groups were diagnosed clinically.Results: Serum of H2O2 and SOD levels was measured for all studied groups. Results showed that there were no significant variances in age and gestational age distribution between all studied groups. Furthermore, result showed that the serum level o
... Show MoreThis work evaluates the influence of combining twisted fins in a triple-tube heat exchanger utilised for latent heat thermal energy storage (LHTES) in three-dimensional numerical simulation and comparing the outcome with the cases of the straight fins and no fins. The phase change material (PCM) is in the annulus between the inner and the outer tube, these tubes include a cold fluid that flows in the counter current path, to solidify the PCM and release the heat storage energy. The performance of the unit was assessed based on the liquid fraction and temperature profiles as well as solidification and the energy storage rate. This study aims to find suitable and efficient fins number and the optimum values of the Re and the inlet tem
... Show More