Preferred Language
Articles
/
nxZJQ4cBVTCNdQwCpD6x
New mini dental implant attachments versus O-ring attachment after cyclic aging: Analysis of retention strength and gap space
...Show More Authors

Crossref
View Publication
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Bactericidal Effect of CO2 Laser on Bacteria Associated With Dental Implant Infection: An In Vitro Study
...Show More Authors

One of the most popular causes for implant infection is dental plaque bacteria. Previous studies have shown the bactericidal effect of CO2 laser irradiation on bacteria associated with soft tissue surrounding the implant materials. No published studies have examined the effect of irradiation by CO2 laser on Streptococcus oralis and Staphylococcus aureus.The aim of this study was to evaluate the bactericidal effect of CO2 laser on bacteria that are causing dental implant infections. This study was carried out on two isolates of bacterial species out of 25 samples, isolated from patients having soft tissue infections around the dental implant. These two pure isolates including Streptococcus oralis and Staphylococcus aureus were identified

... Show More
View Publication Preview PDF
Publication Date
Sat May 30 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of tongue space area in a sample of Iraqi adults with class I dental and skeletal pattern
...Show More Authors

Background: Lateral cephalometric radiography is commonly used as a standard tool in orthodontic assessment and treatment planning. This study aimed to determine the tongue and surrounding space area in a sample of Iraqi adults with class I dental and skeletal pattern. Materials and methods: The study included thirty healthy subjects (15 males and 15 females) with an age ranged between 23-34 years and class I dental and skeletal pattern with no history of any sleep related disorders. The assessed cephalometric measurement included length and height of the tongue and position of hyoid bone from cervical line. Descriptive statistics were obtained for the data. Genders difference was evaluated by independent sample t-test. Results: There wer

... Show More
View Publication Preview PDF
Publication Date
Thu Nov 08 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Evaluation of some mechanical properties of dental alginate impression materials after fluoride addition
...Show More Authors

Objective:Fluorid-containing dental alginate impression materials can exert a considerable reduction in
enamel solubility. The objective was to evaluate the effect of fluoride addition on the setting time and
compressive strength of alginate impression materials.
Methodology: 60 samples were constructed from alginate impression material (30 samples for setting
time test and 30 samples for compressive strength test).Specimens of each test divided into three
subgroup. Group A: 10 specimens of alginate were mixed with distilled water [control], Group B: 10
specimens of alginate were mixed with100-ppm fluoride and Group C:10 specimens of alginate were
mixed with 2%Naf.
Results: the result of setting time test showed t

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 04 2024
Journal Name
Journal Of Emergency Medicine, Trauma And Acute Care
Cone beam computed tomography (CBCT) evaluation of ridge shape and bone density in Iraqi sample pre-dental implant insertion
...Show More Authors

One of the critical factors for dental implant success is accurate clinical and radiological assessment. Cone-beam computed tomography systems (CBCT) allow surgeons to determine the quality and quantity before surgery, aiding in treatment planning. This study highlights the importance of such an assessment Materials and Methods A total of 40 patients were referred to CBCT scanning for pre-dental implant assessment in the Oral and Maxillofacial Radiology department at Al-Shaheed Gazi Al Hariri Hospital from 2021 to 2022. The patients were between 18 and 50 years old. All data were analyzed with on-demand 3D software (Kavo OP 3D: Cone Beam 3D imaging Germany). Results: Regarding the ridge shape: In the upper anterior and posterior regions, th

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sun Sep 04 2016
Journal Name
Baghdad Science Journal
Synthesis of Some New Nucleoside Analogues Containing Seven Membered Ring and Studying Their Biological Activity
...Show More Authors

In this work, a series of new Nucleoside analogues (D-galactopyranose linked to oxepanebenzimidazole moiety) was synthesized via multisteps synthesis. The first step involved preparation of two benzimidazoles 2-styrylbenzimidazole and 2-(phenyl ethynyl) benzimidazole via reaction of phenylenediamine with cinnamic acid or ?-phenyl propiolic acid. Electrophilic addition of the prepared benzimidazoles by three anhydrides in the second step afforded (4-6) and (14-16) which in turn were treated with 1,2,3,4-di-O-isopropylidene galactopyranose in the third step to afford a series of the desirable protected nucleoside analogues (7-9) ,(17-19)which after hydrolysis in methanolic sodium methoxidein the fourth step afforded the free nucleoside analog

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Sep 13 2018
Journal Name
Baghdad Science Journal
Studying Biomimetic Coated Niobium as an Alternative Dental Implant Material to Titanium (in vitro and in vivo study)
...Show More Authors

Commercially pure titanium (cpTi) is widely used as dental implant material although it was found that titanium exhibited high modulus of elasticity and the lower corrosion tendency in oral environment. Niobium(Nb) was chosen for this study as an alternative to cpTi implant material due to its bioinert behavior and good elastic modulus and moderate cost in addition to corrosion resistance. This study was done to evaluate the effect of biomimetic coating on the surface properties of the commercially pure titanium and niobium implants by in vitro and in vivo experiments. The in vitro study was involved etching the samples of each material in HCl then soaking in 10M NaOH aqueous solution. These samples were then immersed in a 5 times concent

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Tue Aug 23 2022
Journal Name
Journal Of Craniofacial Surgery
Differences Between Impression Stone Pouring and Digital Pouring in Fully Guided Dental Implant Surgery: A Prospective Clinical Study
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Mon Aug 01 2022
Journal Name
Baghdad Science Journal
Water Temperature Effect on Hardness and Flexural Strength of (PMMA/TiO2 NPs) for Dental Applications
...Show More Authors

PMMA (Poly methyl methacrylate) is considered one of the most commonly used materials in denture base fabrication due to its ideal properties. Although, a major problem with this resin is the frequent fractures due to heavy chewing forces which lead to early crack and fracture in clinical use. The addition of nanoparticles as filler performed in this study to enhance its selected mechanical properties. The Nano-additive effect investigated in normal circumstances and under a different temperature during water exposure. First, tests applied on the prepared samples at room temperature and then after exposure to water bath at (20, 40, 60) C° respectively. SEM, PSD, EDX were utilized for samples evaluation in this study. Flexural

... Show More
View Publication Preview PDF
Scopus (15)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Sun Jul 23 2023
Journal Name
University Of Samarra
Synthesis, spectral characterization and thermal ‎study of complexes of ions of some metallic ‎elements with new cyclic ligands
...Show More Authors

The purpose of my thesis is to prepare four new ligands (L1-L4) that have been ‎used to prepare a series of metal complexes by reacting them with metal ions:‎ ‎ M=(Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II), Hg(II) ‎ ‎ Where succinyl chloride was used as a raw material for the preparation of ‎bi-dented ligands (L1-L4) by reacting it with potassium thiocyanate as a first ‎step and then reacting with (2-aminobenzothiazole, Benzylamine, 4-‎aminoantipyrine, Sulfamethoxazole) respectively as a second step with the use ‎of dry acetone as a solvent, the chemical formula of the four ligands prepared in ‎succession:‎ N1,N4-bis(benzo[d]thiazol-2-ylcarbamothioyl)succinamide (L1)‎ N1,N4-bis(benzylcarbamothioyl)succinami

... Show More
Publication Date
Mon Dec 20 2021
Journal Name
Journal Of Craniofacial Surgery
The Effect of Bone Density Measured by Cone Beam Computed Tomography and Implant Dimensions on the Stability of Dental Implants
...Show More Authors

Abstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ,

... Show More
View Publication
Scopus (15)
Crossref (18)
Scopus Clarivate Crossref