The process of controlling a Flexible Joint Robot Manipulator (FJRM) requires additional sensors for measuring the state variables of flexible joints. Therefore, taking the elasticity into account adds a lot of complexity as all the additional sensors must be taken into account during the control process. This paper proposes a nonlinear observer that controls FJRM, without requiring equipment sensors for measuring the states. The nonlinear state equations are derived in detail for the FJRM where nonlinearity, of order three, is considered. The Takagi–Sugeno Fuzzy Model (T-SFM) technique is applied to linearize the FJRM system. The Luenberger observer is designed to estimate the unmeasured states using error correction. The developed Luenberger observer showed its ability to control the FJRM by utilizing only the measured signal of the velocity of the motor. Stability analysis is implemented to improve the ability of the designed observer to stabilize the FJRM system. The developed observer is tested by simulation to evaluate the ability of the observer to estimate the unknown states. The results showed that the proposed control algorithm estimated the motor angle, gear angle, link angle, angular velocity of gear, and angular velocity of link with zero steady errors.
Vocational education is the basis of contemporary educational movement that aims at satisfying human needs. Societies can develop their human resources via setting programs for the working class as an aspect of the comprehensive national development. Vocational education is the main source of technical cadres the Iraqi labor market requires of the vocational preparatory schools to provide after three years of schooling.
The vocational schools of the governorate of Basra have a number of problems that lead to the lack of proficiency of their graduates. This study is an attempt to identify these problems or obstacles
... Show MoreAutorías: Omar Saeed Sabbar, Ali Mousa Jawad, Maher Amer Jabbar. Localización: Revista iberoamericana de psicología del ejercicio y el deporte. Nº. 3, 2023. Artículo de Revista en Dialnet.
Abstract The purpose of this paper is preparing exercises according to some biomechanical variables for women with low back pain and identifying the effect of exercise according to some biomechanical variables and relieving lower back pain for women. The researchers used the one-group experimental design. The sample was chosen by the intentional method to provide the necessary conditions for conducting the study, and they represent the research community and its sample. The researchers also excluded (2) of the injured women because they did not adhere to the rehabilitation sessions, and for the purpose of ensuring the homogeneity of the sample members, the researchers used the arithmetic mean, standard deviation, and the torsion coefficient
... Show MoreThis study uses an environmentally friendly and low-cost synthesis method to manufacture zinc oxide nanoparticles (ZnO NPs) by using zinc sulfate. Eucalyptus leaf extract is an effective chelating and capping agent for synthesizing ZnO NPs. The structure, morphology, thermal behavior, chemical composition, and optical properties of ZnO nanoparticles were studied utilizing FT-IR, FE-SEM, EDAX, AFM, and Zeta potential analysis. The FE-SEM pictures confirmed that the ZnO NPs with a size range of (22-37) nm were crystalline and spherical. Two methods were used to prepare ZnO NPs. The first method involved calcining the resulting ZnO NPs, while the second method did not. The prepared ZnO NPs were used as adsorbents for removing acid black 210
... Show MoreEach Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at
... Show MoreMetal-organic frameworks (MOFs) have emerged as revolutionary materials for developing advanced biosensors, especially for detecting reactive oxygen species (ROS) and hydrogen peroxide (H₂O₂) in biomedical applications. This comprehensive review explores the current state-of-the-art in MOF-based biosensors, covering fundamental principles, design strategies, performance features, and clinical uses. MOFs offer unique benefits, including exceptional porosity (up to 10,400 m²/g), tunable structures, biocompatibility, and natural enzyme-mimicking properties, making them ideal platforms for sensitive and selective detection of ROS and H₂O₂. Recent advances have shown significant improvements in detection capabilities, with limit
... Show More