ABSTRACT This study presents an efficient approach for the separation and preconcentration of norepinephrine (NOR) from pharmaceutical formulations, environmental water, and human urine samples using a dispersive micro – solid phase extraction (DμSPE) technique employing magnetic nanoadsorbents. Two adsorbents, Fe3O4@TTAB and Fe3 O4@SiO2@TTAB, were prepared by functionalising iron oxide and silicacoated iron oxide nanoparticles with the cationic surfactant tetradecyltrimethylammonium bromide (TTAB). NOR was first converted into a sensitive diazonium dye via reaction with diazotised sulphamethazine and then extracted using mixed ademicelle – hemimicelle magnetic solid-phase extraction, followed by spectrophotometric quantification. Key adsorption parameters, including contact time, adsorbent dosage, solution pH, and reagent concentration, were optimised to elucidate the dye adsorption mechanism, and sorbent reusability was evaluated over six adsorption – desorption cycles. The surfactant-coated nanoparticles provided high extraction efficiencies, achieving preconcentration factors of 35 for Fe3O4@TTAB and 56 for Fe3O4@SiO2@TTAB, with recoveries of 96–102% and relative standard deviations below 3% for both adsorbents. The method displayed linearity ranges of 0.1–6.0 μg/mL for Fe3O4@TTAB and 0.05–6.0 μg/ mL for Fe3O4@SiO2@TTAB, with detection limits of 0.035 and 0.019 μg/mL, respectively. These results confirm that DμSPE is a reliable and sustainable approach for NOR extraction and preconcentration from diverse matrices.
Purpose: To validate a UV-visible spectrophotometric technique for evaluating niclosamide (NIC) concentration in different media across various values of pH. Methods: NIC was investigated using a UV-visible spectrophotometer in acidic buffer solution (ABS) of pH 1.2, deionized water (DW), and phosphate buffer solution (PBS), pH 7.4. The characterization of NIC was done with differential scanning calorimeter (DSC), powder X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The UV analysis was validated for accuracy, precision, linearity, and robustness. Results: The DSC spectra showed a single endothermic peak at 228.43 °C (corresponding to the melting point of NIC), while XRD and FTIR analysis confirmed the identit
... Show MoreA simple, rapid and environmentally friendly dispersive liquid–liquid microextraction method-based spectrophotometric method for the trace determination of folic acid has been developed. The proposed method is based on the formation of a deep yellow product via reaction of folic acid and 1,2-naphthoquine-4-sulfonate at pH = 9. The formed complex was extracted using a mixture of chloroform and ethanol. Then, the tiny organic droplets were measured at λ = 520 nm. At the optimum conditions, linearity was ranged from 0.05 to 1.5 μg/mL for the standard and samples, with a linear correlation coefficient of 0.9996. The detection limits were 0.02, 0.027, 0.03, 0.02 and 0.04 μg/mL for standard, tablet (5 mg), tablet (1 mg), syrup and fl
... Show MoreIn this study, phosphorescence analysis (KPA) is used for determining soil collected from the Tigris River from Al- Karrada and Bab Al-Sharq in Baghdad and samples were taken from rainwater collected from Al-Rashad, Al-Obeidi, Al-Dora and Al-Sadr City in Baghdad. The measurements were carried out by the Iraqi Ministry of Health and Environment, in the Radiation Protection Center. The collection, removal and evaporation of the samples ranged from January to the end of March 2018. The results show the presents of concentration of 238U and 235U in soil samples and the rainwater samples. The conclusion of this work is the concentration of uranium in soil samples is more than recommendations by ICRP value of 1.9 μg /l. While all water sample
... Show MoreThe research aims to find ways to minimize the use of quantities of chemical fertilizers in agriculture in order to get to an environment that is free of contaminants. Magnetized water technology used in the experience of planting seeds of tomatoes Thomson type to obtain a higher efficiency to absorb fertilizer NRK in the protected environment of the period from February to June. Magnetized water system used locally made levels Gaues (4800,2500,1500) concentrations of 50 to 100% for each level and the rate of (4) replicates, and results indicated that the severity of the magnet (4800 Gaues) and a concentration of 50% gave the highest percentage of tomato fruit size and intensity ( 1500 Gaues) and a concentration of 100% did not give any inc
... Show MoreAbstract
Robust controller design requires a proper definition of uncertainty bounds. These uncertainty bounds are commonly selected randomly and conservatively for certain stability, without regard for controller performance. This issue becomes critically important for multivariable systems with high nonlinearities, as in Active Magnetic Bearings (AMB) System. Flexibility and advanced learning abilities of intelligent techniques make them appealing for uncertainty estimation. The aim of this paper is to describe the development of robust H2/H∞ controller for AMB based on intelligent estimation of uncertainty bounds using Adaptive Neuro Fuzzy Inference System (ANFIS). Simulatio
... Show MoreThis study objective is to identify the visual pollution in Karrada district main streets as an example of main streets in Baghdad, the public opinion about each pollutants, solutions to reduce and eliminate the pollution were suggested as well. In order to accomplish this objective different methods were used, 16 pollutants were selected, pictures of each pollutants were taken and a questioner were distributed randomly for 270 people to evaluate the public opinion with statistical methods. Garbage, their disposal and storage areas took the first two places as the highest offensive pollutants. The people showed that they find long lines of vehicles, debris and generators appearance ranked third, fourth and fifth respectively .This resear
... Show MoreThis paper present a simple and sensitive method for the determination of DL-Histidine using FIA-Chemiluminometric measurement resulted from oxidation of luminol molecule by hydrogen peroxide in alkaline medium in the presence of DL-Histidine. Using 70?l. sample linear plot with a coefficient of determination 95.79% for (5-60) mmol.L-1 while for a quadratic relation C.O.D = 96.44% for (5-80) mmol.L-1 and found that guadratic plot in more representative. Limit of detection was 31.93 ?g DL-Histidine (S/N = 3), repeatability of measurement was less that 5% (n=6). Positive and negative ion interferances was removed by using minicolume containing ion exchange resin located after injection valve position.
