Preferred Language
Articles
/
nBjKFZgBVTCNdQwCyap6
An evaluation of water absorption of Giomer in comparison to other resin-based restorative materials
...Show More Authors

Background: Polymeric composites have been widely used as dental restorative materials. A fundamental knowledge and understanding of the behavior of these materials in the oral cavity is essential to improve their properties and performance. The goal of this study was to measure water sorption of four composite resins containing different filler and resin matrix contents. Materials and method: Resin composite specimens giomer (Beautifil II) Filtek™ P90, Filtek™ Z350 XT, and Tetric N Ceram were prepared in a cylindrical mould of 3mm thickness and 6mm diameter (n=10) and light cured . All specimens placed in silica-gel desiccators at 37˚C for seven days, a constant weight was obtained. All samples were immersed in deionized distilled water at 37˚C and weighed at suitable time interval once a week for 30 days. Water sorption was calculated based on ISO 4049. Data were subjected to student t- test. Results: Silorane and Giomer composites showed the lowest values of water sorption, while Z350 and Tetric N-Ceram displayed the highest values at a period of 4 weeks. Conclusion: Each resin- matrix composite varied in water sorption which may affect clinical service. The attained water sorption values are mainly influenced by the generic type of material and variations occurring between materials of the same type may result from differences in resin matrix compositions.

Publication Date
Tue Dec 27 2022
Journal Name
Journal Of Lasers In Medical Sciences
Influence of Fiber Laser (1064 nm) on Shear Bond Strength of Titanium Abutment and Resin Cement
...Show More Authors

Introduction: The present study was performed to evaluate the influence of a 1064 nm fiber laser on shear bond strength (SBS) at the interface of titanium and resin cement. Methods: Forty titanium discs of 6 mm × 3 mm (diameter and thickness respectively) were categorized into four groups (n=10): control group without any surface treatment and three groups treated with a fiber laser with 81 ns pulse duration, 30 kHz frequency, 10000 mm/s scanning speed, 0.05 mm spot size, and different average power values (3, 5 and 7 W) depending on the tested group. Titanium disc characterization was performed by the scanning electron microscope (SEM) and surface roughness tester. Phase analysis was achieved using an X-ray diffractometer (XRD). F

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Nov 05 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Effect of Addition Retention Bead and Repair Material on Transverse Strength of Repaired Acrylic Denture Resin
...Show More Authors

Objective: One of the most important practical deficiencies of present denture base materials is fracture, therefore many
attempts have been made to reinforce of the repaired denture base resin. A desirable objective for this service is to obtain
optimum strength for repairs, which can be achieved by making available a good bond between original and repaired
materials.
Methodology: The present study was carried out to evaluate and compare the transverse strength of acrylic specimens
repaired by two different materials (hot-cure and cold-cure acrylic resin). A total of 50 specimens were prepared by hot
(40) repair: (10) by hot with retention bead, (10) by cold with retention bead and (10) repair by hot only, (10) repair

... Show More
View Publication Preview PDF
Publication Date
Wed Nov 07 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Effect of metal wire and glass fibers on the impact strength of acrylic denture-base resin
...Show More Authors

Objective(s): The aim of this study is to compare the impact strength of a heat cured denture-base acrylic resin
reinforced with metal wire and glass fibers.

Methodology: Forty five specimens were prepared from pink heat cure acrylic resin. Specimens were grouped into;
group-I (control group) which consists of 15 specimens with no reinforcement, group-II which consists of 15 specimens
reinforced with metal wire, and group-III consists of 15 specimens reinforced with glass fibers. Specimens were tested
by using charpy impact machine.

Results: The result showed that there was a highly significant difference in impact strength value among the testing
groups at (P < 0.001).

Conclusion: The impact str

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of tea tree oil on candida adherence and surface roughness of heat cure acrylic resin
...Show More Authors

Background: Denture cleansing was an important step that could prevent the spread of infection and improve a patient's health, the durability of the dentures, and the overall quality of life; therefore, it was necessary to choose a suitable cleanser that, in addition to being effective, did not have an unfavorable effect on the qualities of the denture base resin itself when used for an extended period. For this purpose, this study aimed to evaluate the effect of tea tree oil (TTO) on Candida albicans adhesion and the surface roughness property of poly(methyl methacrylate) denture material after immersion in TTO. Methods: A total of 55 heat-cured acrylic resin specimens were used for C. albicans adherence and surface roughness tests. The

... Show More
View Publication Preview PDF
Scopus (13)
Crossref (5)
Scopus Crossref
Publication Date
Tue Dec 22 2020
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Measuring Operational Risk on according to International Requirements: An Applied Research in Bank of Baghdad- Private Shareholders Organization
...Show More Authors

This research aims to study and evaluate the reality of the Iraqi banks in terms of how they cope with the risks of the banking business, specifically banking operational risks, and to develop a model integrated to define, identify, measure and mitigate the impact of these risks on according to the Basel Committee requirements II about the dangers of Alchgal.uchir major search to the presence of weak results in the Iraqi banks in understanding and defining and measuring operational risks and not hedged properly, which avoids those banks operating losses as well as the results show there is a shortage in the equation of capital adequacy applied by the Iraqi banks because of non-observance of the minimum capital required to counter the ris

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 28 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of ER: YAG laser on enamel resistance to caries during orthodontic treatment: An in vitro study
...Show More Authors

Background: One common undesirable side effect of orthodontic treatment with fixed appliances is the development of incipient caries lesions around brackets, particularly in patients with poor oral hygiene. Different methods have been used to prevent demineralization; the recent effort to improve the resistance against the demineralization is by the application of lasers. Materials and method: Thirty human premolars extracted for orthodontic purposes were used to test the effect of two energy level of ER-YAG laser on enamel resistance to demineralization. The brackets were bonded on the teeth and all the labial surface excluding 2 mm area gingival to the brackets were painted with acid resistance varnish. Three groups were generated. The fi

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
Al-qadisiyah Medical Journal
Comparison between dome and wedge osteotomy in management of hallux valgus deformity
...Show More Authors

Background: the condition of hallux valgus is considered as the most common deformities affecting females more than males, characteristically manifested as lateral deviation of the big toe and widening of first and second inter -metatarsal angle with a deformity of second toe in some severe cases. Objective: to make a radiological and clinical assessment of two surgical methods of osteotomy used in treatment of hallux valgu and to compare between them: first one is the distal dome osteotomy, and second one is a distal wedge metatarsal osteotomy. Patients and methods: a total of 36 feet of 28 patients suffer from hallux valgus, with mean age of 50.3 years were included in this study, followed for 6- 30 months ( mean follow-up of 8.8 months).

... Show More
Publication Date
Wed Dec 01 2021
Journal Name
Journal Of Economics And Administrative Sciences
Comparison of Some Semi-parametric Methods in Partial Linear Single-Index Model
...Show More Authors

The research dealt with a comparative study between some semi-parametric estimation methods to the Partial linear Single Index Model using simulation. There are two approaches to model estimation two-stage procedure and MADE to estimate this model. Simulations were used to study the finite sample performance of estimating methods based on different Single Index models, error variances, and different sample sizes , and the mean average squared errors were used as a comparison criterion between the methods were used. The results showed a preference for the two-stage procedure depending on all the cases that were used

View Publication Preview PDF
Crossref
Publication Date
Tue Oct 01 2024
Journal Name
Energy And Buildings
Year-round performance evaluation of photovoltaic-thermal collector with nano-modified phase-change material for building application in an arid desert climate zone
...Show More Authors

View Publication
Scopus (19)
Crossref (21)
Scopus Clarivate Crossref
Publication Date
Mon Aug 01 2016
Journal Name
Journal Of Engineering
Evaluation of Bearing Capacity of Strip Foundation Subjected to Eccentric Inclined Loads Using Finite Element Method
...Show More Authors

In real conditions of structures, foundations like retaining walls, industrial machines and platforms in offshore areas are commonly subjected to eccentrically inclined loads. This type of loading significantly affects the overall stability of shallow foundations due to exposing the foundation into two components of loads (horizontal and vertical) and consequently reduces the bearing capacity.

Based on a numerical analysis performed using finite element software (Plaxis 3D Foundation), the behavior of model strip foundation rested on dry sand under the effect of eccentric inclined loads with different embedment ratios (D/B) ranging from (0-1) has been explored. The results display that, the bearing capacity of st

... Show More
View Publication Preview PDF