Background. “Polyetheretherketone (PEEK)” is a biocompatible, high-strength polymer that is well-suited for use in dental applications due to its unique properties. However, achieving good adhesion between PEEK and hydrophilic materials such as dental adhesives or cement can be challenging. Also, this hydrophobicity may affect the use of PEEK as an implant material. Surface treatment or conditioning is often necessary to improve surface properties. The piranha solution is the treatment of choice to be explored for this purpose. Methods. PEEK disks of 10 mm diameter and 2 mm thickness were used in this study. Those samples were divided into five groups (each group has five samples). The first is the control group, in which no acid treatment was used; the second group undergoes sulfuric acid treatment. The remaining three groups were treated with Piranha solution; each group used a different concentration (1 : 3, 1 : 5, and 1 : 7 hydrogen peroxide to sulfuric acid, respectively). The period of treatment was 60 s for all groups. Wettability and surface roughness tests were done for the five groups. In statistical analysis, Shapiro–Wilk test was used to check the assumption of normality and to determine the statistical significance among groups; a one-way analysis of variance was employed. Subsequently, for multiple comparisons, Tukey’s honestly significant difference post hoc test was performed. Results. The Piranha solution treatment groups showed a higher wettability compared to the control group and the group treated with sulfuric acid. Additionally, the Piranha solution treatment with a higher concentration of hydrogen peroxide (1 : 3) resulted in greater improvement in surface roughness compared to the control group and the lower concentration groups (1 : 5 and 1 : 7), while the sulfuric acid treated group showed the highest surface roughness. Conclusion. The results of this study suggest that the piranha solution can be an effective method for improving the surface characteristics of PEEK to be used in different dental applications, especially as a dental implant material, due to the increase in wettability and surface roughness.
In this study, poly4-(nicotinamido)-4-oxo-2-butenoic acid (PNOE) was prepared by the electro polymerization of 4-(nicotinamido)-4-oxo-2-butenoic acid (NOE) monomer on a 316 stainless steel (St.St) which acts as an anticorrosion coating. Fourier transforms infrared (FTIR), atomic force microscopy (AFM), scanning electron microscopy (SEM), and cyclic voltammetry were used to diagnose the structure and the properties of the prepared polymer layer. The corrosion behavior of the uncoated and coated 316 St.St were evaluated by using an electro chemical polarization technique in 0.2 M hydrochloric acid solution as a corrosive medium at a temperature range of 293 to 323 K. Nano materials, such as nano ZnO and graphene were added in di
... Show MoreThis present work is concerned with one of the syntactic issues that has been researched by many linguists, grammarians, and specialists in Islamic studies, the estimated answer to a condition. However, this topic is researched this time by examining Imam Al-Qurtbi’s opinions in interpreting related ayas from the holly Quraan in his book (Collector of Quranic Rules) or its transliteration (Al-Jami’ Li Ahkam Al-Quran). Such a step involves commenting on, tracking what Al-Qurtbi said in this regard, discussing it from the points of view of other grammarians, and judging it accordingly, taking into account the apparent surface structures of the examples collected. To achieve this objective, the inductive analytical approach has be
... Show MoreIn this work , an effective procedure of Box-Behnken based-ANN (Artificial Neural Network) and GA (Genetic Algorithm) has been utilized for finding the optimum conditions of wt.% of doping elements (Ce,Y, and Ge) doped-aluminizing-chromizing of Incoloy 800H . ANN and Box-Behnken design method have been implanted for minimizing hot corrosion rate kp (10-12g2.cm-4.s-1) in Incoloy 800H at 900oC . ANN was used for estimating the predicted values of hot corrosion rate kp (10-12g2.cm-4.s-1) . The optimal wt.% of doping elements combination to obtain minimum hot corrosion rate was calculated using genetic alg
... Show MoreIn this study, plastic wastes named (PET and PVC) were used to prepare polymer matrix composite (PMC) which can be used in different applications. Composite materials were prepared by mixing unsaturated polyester resin (UP) with plastic wastes, two types of plastic waste were used in this work included polyethylene-terephthalate (PET) and Polyvinyl chloride (PVC) with various weight fractions (0, 5,10,15, 20 and 25%) added as a filler in flakes form. In this work, some of the tests that were carried out included (tensile, bending, and compressive strength) as mechanical tests, in addition to (thermal conductivity and water absorption) as physical tests. The values of tensile, compressive strength and Young's modulus of UP increased after
... Show MoreWe study in this paper the composition operator that is induced by ?(z) = sz + t. We give a characterization of the adjoint of composiotion operators generated by self-maps of the unit ball of form ?(z) = sz + t for which |s|?1, |t|<1 and |s|+|t|?1. In fact we prove that the adjoint is a product of toeplitz operators and composition operator. Also, we have studied the compactness of C? and give some other partial results.
This project sought to fabricate a flexible gas sensor based on a short functionalized multi-walled carbon nanotubes (f-MWCNTs) network for nitrogen dioxide gas detection. The network was prepared by filtration from the suspension (FFS) method and modified by coating with a layer of polypyrrole conductive polymer (PPy) prepared by the oxidative chemical polymerization to improve the properties of the network. The structural, optical, and morphological properties of the f-MWCNTs and f-MWCNTs/PPy network were studied using X-ray diffraction (XRD), Fourie-transform infrared (FTIR), with an AFM (atomic force microscopy). XRD proved that the structure of f-MWCNTs is unaffected by the synthesis procedure. The FTIR spectra verified the existence o
... Show MoreABSTRACT Background: Cortical bone thickness is important for the stability of mini implants. Placing mini implants in sites of favorable cortical bone thickness would guarantee better initial stability and long-term success. The aim of this study was to investigate gender, side and jaw differences of the buccal cortical bone thickness as a guide for orthodontic mini screw placement. Materials and Methods: The sample was selected from the patients attending the Specialized Health Center in Al-Sadr City / 3D department. Thirty patients (15 males and 15 females) were selected and cone beam computerized tomographic images were done. Then the buccal cortical bone thickness was measured at thirteen inter radicular sites in the maxilla and mandib
... Show More