Kurdistan power system is expanded along years ago. The electrical power is transmitted through long transmission lines. The main problem of transmission lines is active and reactive power losses. It is important to solve this issue, unless, the most of electrical energy will lost over transmission system. In this study, High Voltage Direct Current links/bipolar connection were connected in a power system to reduce the power losses. The 132kV, 50 Hz, 36 buses Kurdistan power system is used as a study case. The load flow analysis was implemented by using ETAP.16 program in which Newton-Raphson method for three cases. The results show that the losses are reduced after inserted HVDC links.
This study investigates the Linguistic and Conceptual equivalence of Conner’s Revised Scales when applied on a Sudanese sample. Sudanese parents and teachers completed behavior-rating scales on a stratified sample of 200 children. These instruments were based on Conner’s parent -48 and teacher-28 questionnaires. Following a reliable translation into Sudanese Arabic the test-retest reliability of the items and the internal consistency of the original Conner’s' revised scales were explored. The associations between scale scores and between parents and teachers scores were also examined. Both instruments displayed good reliability and the original Conners scales had satisfactory internal consistency. The inter-correlation sugg
... Show MoreThe research aimed to test the effect of independent variables career plateaus and workaholism on employees loyalty through the influence of the mediator variable organizational socialization. Descriptive approach with survey style on a sample of managers and executives in the Iraqi Drilling Company in Basra's (123) employees. The most important findings of the research are: the existence of a significant effect of the independent variables career plateaus and workaholism in employees loyalty by having a mediator variable organizational socialization and introduced numerical from recommendations. &nbs
... Show MoreInformation and communication technology has a significant influence on employee procedures. Businesses are investing in e-CRM technologies, yet it is difficult to assess the performance of their e-CRM platforms. The DeLone and McLean Information Systems Success framework can be modified to the current e-CRM assessment difficulties. The new framework's different aspects provide a concise framework for organizing the e-CRM key metrics identified in this study. The purpose of this study is to apply and verify that the Updated DeLone and McLean IS Model can be employed to explain e-CRM adoption among employees, along with the extended Updated DeLone and McLean Model with its five output factors, namely system quality, service quality,
... Show MoreTigris River is the lifeline that supplies a great part of Iraq with water from north to south. Throughout its entire length, the river is battered by various types of pollutants such as wastewater effluents from municipal, industrial, agricultural activities, and others. Hence, the water quality assessment of the Tigris River is crucial in ensuring that appropriate and adequate measures are taken to save the river from as much pollution as possible. In this study, six water treatment plants (WTPs) situated on the two-banks of the Tigris within Baghdad City were Al Karkh; Sharq Dijla; Al Wathba; Al Karama; Al Doura, and Al Wahda from northern Baghdad to its south, that selected to determine the removal efficiency of turbidity and
... Show MoreArtificial roughness on the absorber plate of a Solar Air Heater (SAH) is a popular technique for increasing its effective efficiency. The study investigated the effect of geometrical parameters of discrete multi-arc ribs (DMAR) installed below the SAH absorber plate on the effective efficiency. The effects of major roughness factors, such as number of gaps (Ng = 1-4), rib pitch (p/e = 4-16), rib height (e/D = 0.018-0.045), gab width (wg/e = 0.5-2), angle of attack ( = 30-75), and Reynolds number (Re= 2000-20000) on the performance of a SAH are studied. The performance of the SAH is evaluated using a top-down iterative technique. The results show that as Re rises, SAH-effective DMAR's efficiency first ascends to a specified value o
... Show MoreAbstract- Plasma parameters in a planar dc-sputtering discharge in argon were measured by cylindrical electrostatic probe (Langmuir probe).Electron density, electron temperature, floating potential, and space potential were monitored as a function of working discharge pressure. Electrostatic probe and supporting circuit were described and used to plot the current – voltage characteristics. Plasma properties were inferred from the current-voltage characteristics of a single probe positioned at the inter-cathode space. Typical values are in the range of (10-16 -10-17) m-3 and (2.93 – 5.3) eV for the electron density and the electron temperature respectively.
Objectives: The study aims to evaluate patients’ performance toward insulin injection after training program to
identify the variation in skill of patients in insulin injection technique with regard to some variable (i.e.
educational level and duration of insulin injection.
Methodology: A quasi experimental study has been conducted on diabetic patients.
An observational checklist had been prepared which consisted of 4 main areas with 37 sub-items, which are
syringe preparation for injection, insulin drawing; skin preparation for injection and insulin injection. Each of the
sub-items has 2 options yes or no. One score for positive answer and zero for no.
The sample of the study consisted of (n =30) males and females