Petroleum refinery wastewater treatment using a novel combined electro-Fenton and photocatalytic process
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Sat Dec 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Performance Study of Electrodialysis for Treatment Fuel Washing Wastewater
...Show More Authors

In this work, electrodialysis (ED) has been demonstrated to be appropriate technique for reducing the electrical conductivity of real wastewater from fuel washing unit, which has been previously treated by other electrochemical technology (electrocoagulation and electrooxidation).  A five cell electrodialysis stack, with an active membrane area of 60 cm2 per cell was employed. During a batch recirculation mode ED system, the effects of parameters such as electrical potential applied (6-18 V) and flow rate of streams (0.5-1.7 L/min.) on the performance of the total dissolved solids (TDS) separation and specific power consumption (SPC) were studied. The results indicate that the process of ED under potential (15 V) and flow

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 01 2020
Journal Name
Journal Of Engineering
Performance Evaluation of Trickling Filter and Extended Aeration of Wastewater Treatment Plants
...Show More Authors

In recent decades, there has been increasing interest in wastewater treatment because of its direct impact on the environment and public health. Over time, other forms of treatment have been developed and modified, including extended aeration. This process is included in the suspended growth system. In this paper, a comparative study was conducted between the efficiency of the extended aeration plant and that of the trickling filter plant in removal of BOD and COD.  The method of comparison was done by knowing the value of the pollutant before and after the treatment and then extract the removal ratio of each pollutant within each plant. The results showed that the percentage of removal of BOD in the trickling filte

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Science Of The Total Environment
Recent advances and applicable flexibility potential of electrochemical processes for wastewater treatment
...Show More Authors

This study examined >140 relevant publications from the last few years (2018–2021). In this study, classification was reviewed depending on the operation's progress. Electrocoagulation (EC), electrooxidation (EO), electroflotation (EF), electrodialysis (ED), and electro-Fenton (EFN) processes have received considerable attention. The type of action (individual or hybrid) for each electrochemical procedure was evaluated, and statistical analysis was performed to compare them as a new manner of reviewing cited papers providing a massive amount of information efficiently to the readers. Individual or hybrid operation progress of the electrochemical techniques is critical issues. Their design, operation, and maintenance costs vary depending o

... Show More
View Publication
Scopus (91)
Crossref (91)
Scopus Clarivate Crossref
Publication Date
Mon Feb 19 2024
Journal Name
Journal Of Engineering
Predicting Biochemical Oxygen Demand at the Inlet of Al-Rustumiya Wastewater Treatment Plant Using Different Mathematical Techniques
...Show More Authors

Water quality planning relies on Biochemical Oxygen Demand BOD. BOD testing takes five days. The Particle Swarm Optimization (PSO) is increasingly used for water resource forecasting. This work designed a PSO technique for estimating everyday BOD at Al-Rustumiya wastewater treatment facility inlet. Al-Rustumiya wastewater treatment plant provided 702 plant-scale data sets during 2012-2022. The PSO model uses the daily data of the water quality parameters, including chemical oxygen demand (COD), chloride (Cl-), suspended solid (SS), total dissolved solids (TDS), and pH, to determine how each variable affects the daily incoming BOD. PSO and multiple linear regression (MLR) findings are compared, and their performance is evaluated usin

... Show More
View Publication
Crossref
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
Operational assessment of biological wastewater treatment using advanced return-mass reactors based on principal component cluster analysis
...Show More Authors
Abstract<p>In this study, field results data were conducted, implemented in 64 biofilm reactors to analyses extract organic matter nutrients from wastewater through a laboratory level nutrient removal process, biofilm layer moving process using anaerobic aerobic units. The kinetic layer biofilm reactors were continuously operating in Turbo 4BIO for BOD COD with nitrogen phosphorous. The Barakia plant is designed to serve 200,000 resident works on biological treatment through merge two process (activated sludge process, moving bed bio reactio MBBR) with an average wastewater flow of 50,000 m3/day the data were collected annually from 2017-2020. The water samples were analysis in the central labor</p> ... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Thu Feb 01 2024
Journal Name
Journal Of Engineering
Predicting Biochemical Oxygen Demand at the Inlet of Al-Rustumiya Wastewater Treatment Plant Using Different Mathematical Techniques
...Show More Authors

Water quality planning relies on Biochemical Oxygen Demand BOD. BOD testing takes five days. The Particle Swarm Optimization (PSO) is increasingly used for water resource forecasting. This work designed a PSO technique for estimating everyday BOD at Al-Rustumiya wastewater treatment facility inlet. Al-Rustumiya wastewater treatment plant provided 702 plant-scale data sets during 2012-2022. The PSO model uses the daily data of the water quality parameters, including chemical oxygen demand (COD), chloride (Cl-), suspended solid (SS), total dissolved solids (TDS), and pH, to determine how each variable affects the daily incoming BOD. PSO and multiple linear regression (MLR) findings are compared, and their perfor

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri May 02 2014
Journal Name
International Journal Of Scientific & Technology Research
Synthesis, Structure And Characterization Of Zns Qds And Using It In Photocatalytic Reaction
...Show More Authors

ZnS nanoparticles were prepared by a simple microwave irradiation method under mild condition. The starting materials for the synthesis of ZnS quantum dots were zinc acetate (R & M Chemical) as zinc source, thioacetamide as a sulfur source and ethylene glycol as a solvent. All chemicals were analytical grade products and used without further purification. The quantum dots of ZnS with cubic structure were characterized by X-ray powder diffraction (XRD), the morphology of the film is seen by scanning electron microscopy (SEM). The particle size is determined by field effect scanning electron microscopy (FESEM), UV-Visible absorption spectroscopy and XRD. UV-Visible absorption spectroscopy analysis shows that the absorption peak of the as-prep

... Show More
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Photocatalytic removal of methylene blue dye by using of ZnS and CdS
...Show More Authors

Photocatalytic degradation of methylene blue was studied using CdS and ZnS as catalyst. The photocatalytic activity of the specimen was studied by exposing to UV-radiation. The result shows that the degradation efficiency of the dye for CdS micro-particles was 92% after 7 hours and for ZnS micro-particles was 88.29% for the same time interval.

View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Using Alternative Cogeneration Plants in Iraqi Petroleum Industry
...Show More Authors

The present paper describes and analyses three proposed cogeneration plants include back pressure steam-turbine system, gas turbine system, diesel-engine system, and the present Dura refinery plant. Selected actual operating data are employed for analysis. The same amount of electrical and thermal product outputs is considered for all systems to facilitate comparisons. The theoretical analysis was done according to 1st and 2nd law of thermodynamic. The results demonstrate that exergy analysis is a useful tool in performance analysis of cogeneration systems and permits meaningful comparisons of different cogeneration systems based on their merits, also the result showed that the back pressure steam-turbine is more efficient than other pro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Sep 27 2022
Journal Name
Journal Of Engineering Research And Sciences
Images Compression using Combined Scheme of Transform Coding
...Show More Authors

Some problems want to be solved in image compression to make the process workable and more efficient. Much work had been done in the field of lossy image compression based on wavelet and Discrete Cosine Transform (DCT). In this paper, an efficient image compression scheme is proposed, based on a common encoding transform scheme; It consists of the following steps: 1) bi-orthogonal (tab 9/7) wavelet transform to split the image data into sub-bands, 2) DCT to de-correlate the data, 3) the combined transform stage's output is subjected to scalar quantization before being mapped to positive, 4) and LZW encoding to produce the compressed data. The peak signal-to-noise (PSNR), compression ratio (CR), and compression gain (CG) measures were used t

... Show More
View Publication Preview PDF
Crossref