Electrochemical oxidation in the presence of sodium chloride used for removal of phenol and any other organic by products formed during the electrolysis by using MnO2/graphite electrode. The performance of the electrode was evaluated in terms fraction of phenol and the formed organic by products removed during the electrolysis process. The results showed that the electrochemical oxidation process was very effective in the removal of phenol and the other organics, where the removal percentage of phenol was 97.33%, and the final value of TOC was 6.985 ppm after 4 hours and by using a speed of rotation of the MnO2 electrode equal to 200 rpm.
The earth-air heat exchanger (EHX) has a promising potential to passively save the energy consumption of traditional air conditioning systems while maintaining a high degree of indoor comfort. The use of EHX systems for air conditioning in commercial and industrial settings offers several environmental benefits and is capable of operating in both standalone and hybrid modes. This study tests the performance and effectiveness of an EHX design in a sandy soil area in Baghdad, Iraq. The area has a climate of the subtropical semi-humid type. Ambient air temperatures and soil temperatures were recorded throughout the months of 2021. During the months of January and June, the temperatures of the inlet and outflow air at varying air veloci
... Show MoreJob stress is considered one of the most important obstacles that may appear in the work field. In order to deal with the obstacles and challenges , the idea to deal with job stress has come to address job stress as one of the most important trends that enable organizations to face those challenges through focusing on the role of job stress and the organizational climate of the organization.
The research deals with two variables: the job stress as an independent variable, and the organizational climate as a dependent one. Each variable includes five sub-dimensions. These dimensions have been involved in an interaction to form
... Show MoreThis study aims to establish an empirical correlation between biochemical oxygen demand (BOD5) and chemical oxygen demand (COD) of the sewage flowing in Al-Diwaniyah wastewater treatment plant. The strength of the wastewater entering the plant varied from medium to high. High concentrations of BOD5 and COD in the effluent were obtained due to the poor performance of the plant. This was observed from the BOD5 /COD ratios that did not confirm with the typical ratios for the treated sewage. To improve the performance of this plant, regression equations for BOD5 and COD removal percentages were suggested which can be used to facilitate rapid effluent assessment or optimal process control. The equations relating the percentage removal of
... Show MoreResearchers have shown considerable interest in the idea of organizational climate because of its crucial role in school administration and all school operations. Hence, enhancing it is regarded as a primary duty of school principals, as they bear direct accountability for overseeing the school and its entire operations. Total quality management is a primary method that allows the school administrator to effectively handle administrative tasks with the goal of meeting the needs of instructors, students, staff members, and the community. The significance of the research rests in its attempt to shed light on the value of both organizational climate and total quality management among high school principals. The research seeks to determine the
... Show MoreIron slag is a byproduct generated in huge quantities from recycled remnants of iron and steel factories; therefore, the possibility of using this waste in the removal of benzaldehyde from contaminated water offers an excellent topic in sustainability field. Results reveal that the removal efficiency was equal to 85% for the interaction of slag and water contaminated with benzaldehyde at the best operational conditions of 0.3 g/100 mL, 6, 180 min, and 250 rpm for the sorbent dosage, initial pH, agitation time, and speed, respectively with 300 mg/L initial concentration. The maximum uptake capacity of iron slag was 118.25 mg/g which was calculated by the Langmuir model. Physical sorption may be the major mechanism for the removal of
... Show MoreSerum levels of iron,copper,ceruloplasmin and transferrine were estimated in three groups of patients with ?- thalassemia: 24 patients have splenectomy thalassemia major, 29 patients have non splenectomy thalassemia major and 19 patients have thalassemia intermedia , data were compared to normal and pathological controls (anemia and minor). There were significant increase in trace element levels in all studied groups of pateints as compared to normal and pathological controls. Also there were a significant increase in ceruloplasmin levels,While the result revealed that there were a significant decrease in transferrine levels in all groups of patients studied as compared to normal and pathological controls. The result also indicate that the
... Show MoreAs a marker of systemic inflammation, raised (C-reactive protein (CRP)) concentrations which are still within the normal range have been associated with an increased inflammation of chronic renal diseases (CRD). The current study aimed to establish potential determinats of raised CRP concentrations in patients who treated in Heamodialysis room,then study the relationship between CRP& some biochemical parameters related CRD We used a CRP latex reagents Kit which is based on an immunological reaction between CRP antisera bounded to the biologically inert latex particles or with CRP in the test specimens of 19 patients with (CRD) mean age 48 years ,range = 30?65 & in 21 healthy subjects as control group their age range = 30 ?45 years. The
... Show MoreThe aim of the present study is to compare the biochemical action of the three vaccines taken in Iraq: Pfizer Biontech, AstraZeneca Oxford and Sinopharm based on biochemical parameters. Seventy COVID-19 Iraqi patients ( males and females ) were participated in the present study and classified into 7 groups : Gc : COVID-19 patients ( without vaccine ) , Gp1: COVID-19 patients took one dose of Pfizer Biontech, Gp2 : COVID-19 patients took two doses of Pfizer Biontech, Ga1 : patients took one dose of AstraZeneca Oxford vaccine , Ga2: patients took two doses of AstraZeneca Oxford vaccine , Gs1 : patients took one dose of Sinopharm vaccine and Gs2:
... Show MoreAbstract
Electrical magnate was designed and constructed, the optimum Magnetic flux and the effect of time on the physical properties of the alkaline (magnetic water) produced from the bottled drinking water [the total dissolved solids (TDS) or the electrical conductivity, and pH] were studied, to simulate ZamZam water in Mekka Saudi Arabia. Also, the efficiency of magnetic field from this designed electrical magnate in decreasing the TDS of sea water (of 1500 ppm NaCl Content), to convert it to water suitable for irrigation (TDS<1000 ppm) was investigated in this work.The results show that the magnetic flux from our designed electrical magnate in the range of (0.013- 0.08) Tesla and 30 minut
... Show More