Background: The iron deficiency anemia along with hyperphosphatemia are the main complications of dialysis patients. Traditional iron supplement has been failed to correct iron deficiency anemia, therefore, the current study aimed to investigate the efficacy and tolerability of new phosphate binder, ferric citrate, in a sample of Iraqi patients with end stage renal disease on maintenance hemodialysis. Method: Prospective, randomized, open label, active controlled trial was conducted in one center for dialysis in Babylon governance. Patients were randomized to receive ferric citrate with dose of 6 g/d and calcium carbonate with dose of 3 g/d for eight weeks. Hemoglobin concentration, mean corpuscular hemoglobin concentration and count of RBCs along with iron store parameters were measured. The adherence and gastrointestinal side effects were reported at the end of study. Results: A total of 50 patients were completed the study. Ferric citrate group showed elevation in count of RBCs, hemoglobin concentration, MCH-C and reduction in use of IV iron and erythropoietin as well as increased iron store which evidenced by elevation of ferritin level in the participants. There were similar adverse effects in both groups, with good adherence seen in ferric citrate group. Conclusion: A treatment with ferric citrate for 8 weeks was observed to effectively improve anemia in a sample of Iraqi patients with end stage renal disease on maintenance hemodialysis. In addition, the use of intravenous iron and erythropoietin was reduced in ferric citrate group with well tolerability throughout the study period. Ferric citrate may be useful alternative for restoring iron level in hemodialysis patients.
Abstract
The aim of this paper is to investigate and discuss the mechanisms of corrosion of epoxy coatings used for potable water tanks. Two distinct types of Jotun epoxy coatings: Tankguard 412 contained polyamine cured epoxy and Penguard HB contained polyamide cured epoxy, were tested and studied using the electrochemical impedance spectroscopic (EIS) method. The porosity of epoxy coatings was determined using EIS method. The obtained results showed that the two epoxy coatings have excellent behavior when applied and tested in potable water of Basrah city. Polyamine is more resistance to water corrosion compared to polyamide curing epoxy and has high impedance values. Microscopic inspection after te
... Show MoreKE Sharquie, AA Noaimi, S Adnan, AM Al-Niddawi, WK Aljanabi, American Journal of Dermatology and Venereology, 2020 - Cited by 2
Background: Radiotherapy, is therapy using ionizing radiation in order to deliver an optimal dose of either particulate or electromagnetic radiation to a particular area of the body with minimal damage to normal tissues. The source of radiation may be outside the body of the patient (external beam irradiation) or it may be an isotope that has been implanted or instilled into abnormal tissue or a body cavity. Called also radiotherapy. The aim of work studies the relationship between the depth dose and the high photon xray energies (6MeV and 10MeV). Patients and methods: in our work, we studied the dose distribution in water phantom given at different depths (zero-18) cm deep at1cm intervals treated with different field size (5×5-,10×1
... Show MoreA new simple, sensitive and inexpensive method has been developed for the spectrophotometric determination of cisapride in pharmaceutical formulation. The turbidimetric method is based on the formation of the ion-pair complex between the drug and bromophenol blue (BPB) in presence of potassium chloride at pH= 2.6, with a maximum absorbance at 520 nm. The calibration graph is linear in the concentration range 5-50µg.ml-1 , with good correlation coefficient (r = 0.9989).The limit of detection was found to be 1.14 µg.ml-1 and no interference was observed from common excipients in the pharmaceutical preparation that contain cisapride with good accuracy and precision.
In this manuscript has investigated the synthesis of plasma-polymerized pyrrole (C4H5N) nano-particles prepared by the proposed atmospheric pressure nonequilibrium plasma jet through the parametric studies, particularly gas flow rate (0.5, 1 and 1.5 L/min). The plasma jet which used operates with alternating voltage 7.5kv and frequency 28kHz. The plasma-flow characteristics were investigated based on optical emission spectroscopy (OES). UV-Vis spectroscopy was used to characterize the oxidization state for polypyrrole. The major absorption appears around 464.1, 449.7 and 435.3 nm at the three flow rate of argon gas. The chemical composition and structural properties of the
... Show MoreIn this work, nanostructure aluminum oxide thin films were deposited on glass substrates using a direct current (DC) magnetic reactive sputtering (MRS) technique. A gaseous mixture of argon and oxygen at different mixing ratios was used to synthesize Al2O3 nanoparticles. After extracting Al2O3 powder from the glass substrate, X-ray diffraction (XRD), field-emission scanning electron microscopy (FE-SEM), and energy-dispersive spectroscopy (EDS) were used to analyze the structural and morphological properties of the synthesized thin films. The effect of deposition time on the spectral properties, as well as on the size of the nanoparticles, was determined.