Background: The iron deficiency anemia along with hyperphosphatemia are the main complications of dialysis patients. Traditional iron supplement has been failed to correct iron deficiency anemia, therefore, the current study aimed to investigate the efficacy and tolerability of new phosphate binder, ferric citrate, in a sample of Iraqi patients with end stage renal disease on maintenance hemodialysis. Method: Prospective, randomized, open label, active controlled trial was conducted in one center for dialysis in Babylon governance. Patients were randomized to receive ferric citrate with dose of 6 g/d and calcium carbonate with dose of 3 g/d for eight weeks. Hemoglobin concentration, mean corpuscular hemoglobin concentration and count of RBCs along with iron store parameters were measured. The adherence and gastrointestinal side effects were reported at the end of study. Results: A total of 50 patients were completed the study. Ferric citrate group showed elevation in count of RBCs, hemoglobin concentration, MCH-C and reduction in use of IV iron and erythropoietin as well as increased iron store which evidenced by elevation of ferritin level in the participants. There were similar adverse effects in both groups, with good adherence seen in ferric citrate group. Conclusion: A treatment with ferric citrate for 8 weeks was observed to effectively improve anemia in a sample of Iraqi patients with end stage renal disease on maintenance hemodialysis. In addition, the use of intravenous iron and erythropoietin was reduced in ferric citrate group with well tolerability throughout the study period. Ferric citrate may be useful alternative for restoring iron level in hemodialysis patients.
The impacts of numerous important factors on the Energy Absorption (EA) of torsional Reinforced Concrete (RC) beams strengthened with external FRP is the main purpose and innovation of the current research. A total of 81 datasets were collected from previous studies, focused on the investigation of EA behaviour. The impact of nine different parameters on the Torsional EA of RC-beams was examined and evaluated, namely the concrete compressive strength (f’c), steel yield strength (fy), FRP thickness (tFRP), width-to-depth of the beam section (b/h), horizontal (ρh) and vertical (ρv) steel ratio, angle of twist (θu), ultimate torque (Tu), and FRP ultimate strength (fy-FRP). For the evaluation of the energy absorption capacity at di
... Show MoreThe performance analyses of 15 kWp (kW peak) Grid -Tied solar PV system (that considered first of its type) implemented at the Training and Energy Research Center Subsidiary of Iraqi Ministry of Electricity in Baghdad city has been achieved. The system consists of 72 modules arranged in 6 strings were each string contains 12 modules connected in series to increase the voltage output while these strings connected in parallel to increase the current output. According to the observed duration, the reference daily yields, array daily yields and final daily yields of this system were (5.9, 4.56, 4.4) kWh/kWp/day respectively. The energy yield was 1585 kWh/kWp/year while the annual total solar irradiation received by solar array system was 198
... Show MoreThis study was design to investigate the dimensional stability of heat-activated acrylic resin with different methods of flask cooling (15 minutes rapid cooling, one hour bench cooling, four hours delayed deflasking, and 24 hours delayed deflasking) at different time intervals (immediately, two days, seven days, 30 days) after deflasking. Heat-activated acrylic resin was used to prepare acrylic samples. Then, measurement of the distances where achieved between the centers of selected marks in the acrylic samples. They were measured at different time intervals for different methods of flask cooling. The results showed that the group samples of the four hours and 24 hours of delayed deflasking was insignificantly different from the control an
... Show More