Preferred Language
Articles
/
lobTU4YBIXToZYAL64Ih
Physical Adsorption, Chemical Adsorption, Surface Area, Pore Size distribution, HDS catalyst
...Show More Authors

Physical and chemical adsorption analyses were carried out by nitrogen gas using ASTM apparatus at 77 K and hydrogen gas using volumetric apparatus at room temperature respectively. These analyses were used for determination the effect of coke deposition and poisoning metal on surface area, pore size distribution and metal surface area of fresh and spent hydrodesulphurization catalyst Co-MoAl2O3 .Samples of catalyst (fresh and spent) used in this study are taken from AL-Dura refinery. The results of physical adsorption shows that surface area of spent catalyst reduced to third compare with fresh catalyst and these catalysts exhibit behavior of type four according to BET classification ,so, the pores of these samples are cylindrical, and the pores of fresh catalyst suffers during the hydrodesulphurization .The result of chemical adsorption shows that the metal surface area of fresh catalyst is 50.72 m2/g while it reduced to 39.04 m2/g for spent catalyst.

Preview PDF
Quick Preview PDF
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Enamel Surface after Debonding of Different Types of Esthetic Brackets (An In Vitro Study)
...Show More Authors

Background: Debonding orthodontic brackets and removal of residual bonding material from the enamel surface include critical steps that may cause enamel damage. The aim of the present study was to evaluate and compare the site of bond failure and enamel surface damage after debonding of three types of esthetic brackets (composite, ceramic, sapphire) bonded with light cure composite and resin-modified glass ionomer adhesive. Materials and methods: Seventy two maxillary premolars teeth were divided into three groups each group consisted of 24 teeth according to the type of brackets. Each group was subdivided into two subgroups (12 teeth for each) according to the bonding material that was used. After 7 days of bonding procedure, the brackets

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Dec 31 2016
Journal Name
Al-kindy College Medical Journal
Correlation of CD44v6 and type IV collagen immunohistochemical expression in borderline and malignant surface epithelial tumors
...Show More Authors

Background: the difference in expression of type IV collagen in borderline tumors and ovarian carcinomas has been studied, but the association with adhesion molecules like CD44 have not gain enough interest. Objectives: The purpose of this study is to assess the expression of CD44v6 and type IV collagen status in borderline tumors and invasive ovarian carcinomas and the correlation between them to define the role of these molecules in tumor invasion and metastasis. Type of the study: A cross sectional study Methods: The study included a total of (101) formalin-fixed paraffin-embedded ovarian tissue blocks; of which (19) cases were borderline tumors and (82) cases were overt ovarian carcinomas. Sections from each block were immunohistoche

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of Mechanical Engineering Research And Developments
Effect of the shot peening surface treatment on the corrosion behavior of 2024-T3 aluminum alloy
...Show More Authors

Preview PDF
Scopus (2)
Scopus
Publication Date
Sun Mar 18 2018
Journal Name
Mustansiria Dental Journal
The Effect of Pepsi Cola Beverage on Surface Roughness of Two Composite Resins (In Vitro study)
...Show More Authors

An acidic environment causes surface changes of resin composites. Filler particlesize and filler distribution also have a direct effect on these surface changes. This invitro study evaluated the influence of Pepsi Cola drink on the surface roughness ofComposan LCM and Composan Ceram over time. Sixteen disc shaped specimens(10mm diameter, 2mm thickness) of each resin composite were fabricated, therebyforming two groups (n= 8). Surface roughness (Ra) was analyzed after 24 hrs beforeexposure to beverage. The specimens were submitted to a five minutes immersion inPepsi Cola three times daily interrupted by immersion in deionized distilled water (37C˚). Surface roughness measurements were done at 10, 30, and 60 days intervals. Datawere

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Feb 06 2023
Journal Name
Journal Of Kufa-physics
No-Core optical fibers sensor for detecting hemoglobin concentration (HB) based on the Surface Plasmon resonance.
...Show More Authors

In this work, a fiber-optic biomedical sensor was manufactured to detect hemoglobin percentages in the blood. SPR-based coreless optical fibers were developed and implemented using single and multiple optical fibers. It was also used to calculate refractive indices and concentrations of hemoglobin in blood samples. An optical fiber, with a thickness of 40 nanometers, was deposited on gold metal for the sensing area to increase the sensitivity of the sensor. The optical fiber used in this work has a diameter of 125μm, no core, and is made up of a pure silica glass rod and an acrylate coating. The length of the fiber was 4cm removed buffer and the splicing process was done. It is found in practice that when the sensitive refractive i

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of Mouth Rinses on Surface Roughness of Two Methacrylate-Based and Siloraine-Based Composite Resins
...Show More Authors

Background: Various fluids in the oral environment can affect the surface roughness of resin composites. This in vitro study was conducted to determine the influence of the mouth rinses on surface roughness of two methacrylate-based resin (nanofilled and packable composite) and siloraine-based resin composites.

Materials and methods: Disc-shaped specimens (12 mm in diameter and 2mm in height) were prepared from three types of composi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Sep 08 2022
Journal Name
Al-khwarizmi Engineering Journal
Performance Prediction in EDM Process for Al 6061 Alloy Using Response Surface Methodology and Genetic Algorithm
...Show More Authors

The Electric Discharge (EDM) method is a novel thermoelectric manufacturing technique in which materials are removed by a controlled spark erosion process between two electrodes immersed in a dielectric medium. Because of the difficulties of EDM, determining the optimum cutting parameters to improve cutting performance is extremely tough. As a result, optimizing operating parameters is a critical processing step, particularly for non-traditional machining process like EDM. Adequate selection of processing parameters for the EDM process does not provide ideal conditions, due to the unpredictable processing time required for a given function. Models of Multiple Regression and Genetic Algorithm are considered as effective methods for determ

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Tue Aug 01 2023
Journal Name
Journal Of Ecological Engineering
Optimization of Response Surface Methodology for Removal of Cadmium Ions from Wastewater using Low Cost Materials
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Optical Materials
Design and analysis of a high sensitivity open microchannel PCF-based surface plasmon resonance refractometric sensor
...Show More Authors

View Publication
Scopus (29)
Crossref (30)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Ecological Engineering
Chromium Ions Removal by Capacitive Deionization Process – Optimization of the Operating Parameters with Response Surface Methodology
...Show More Authors

An innovative desalination method called electrosorption or capacitive deionization (CDI) has significant benefits for wastewater treatment. This process is performed by using a carbon fiber electrode as a working electrode to remove hexavalent chromium ions from an aqueous solution. The pH, NaCl concentration, and cell voltage were optimized using the Box-Behnken experimental design (BDD) in response surface methodology (RSM) to study the effects and interactions of selected variables. To attain the relationship between the process variables and chromium removal, the experimental data were subjected to an analysis of variance and fitted with a quadratic model. The optimum conditions to remove Cr(VI) ions were: pH of 2, a cell voltage of 4.

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (8)
Scopus Clarivate Crossref