A novel demountable shear connector for precast steel‐concrete composite bridges is presented. The connector uses high‐strength steel bolts, which are fastened to the top flange of the steel beam with the aid of a special locking nut configuration that prevents slip of bolts within their holes. Moreover, the connector promotes accelerated construction and overcomes typical construction tolerances issues of precast structures. Most importantly, the connector allows bridge disassembly, and therefore, can address different bridge deterioration scenarios with minimum disturbance to traffic flow, i.e. (i) precast deck panels can be rapidly uplifted and replaced; (ii) connectors can be rapidly removed and replaced; and (iii) steel beams can be replaced, while precast decks and shear connectors can be reused. A series of push‐out tests are conducted to assess the behavior of the connector and quantify the effect of important parameters. The experimental results show shear resistance, stiffness, and slip capacity significantly higher than those of welded shear studs along with superior stiffness and strength against slab uplift. Identical tests reveal negligible scatter in the shear load – slip displacement behavior. A design equation is proposed to predict the shear resistance with absolute error less than 8%.
Improving in assembling technology has provided machines of higher evaluation with better resistances and managed behavior. This machinery led to remarkably higher dynamic forces and therefore higher stresses. In this paper, a dynamic investigation of rectangular machine diesel and gas engines foundation at the top surface of one-layer dry sand with various states (i.e., loose, medium and dense) was carried out. The dynamic investigation is performed numerically by utilizing limited component programming, PLAXIS 3D. The soil is accepted as flexible totally plastic material submits to Mohr-Coulomb yield basis. A harmonic load is applied at the foundation with amplitude of 10 kPa at a frequency of (10, 15 and 20) HZ and se
... Show MoreIn this article, a new deterministic primality test for Mersenne primes is presented. It also includes a comparative study between well-known primality tests in order to identify the best test. Moreover, new modifications are suggested in order to eliminate pseudoprimes. The study covers random primes such as Mersenne primes and Proth primes. Finally, these tests are arranged from the best to the worst according to strength, speed, and effectiveness based on the results obtained through programs prepared and operated by Mathematica, and the results are presented through tables and graphs.
This paper reports the synthesis and use of a novel metal-organic framework (MOF), named Zr-BADS, within the thin-film nanocomposite (TFN) membranes for reverse osmosis (RO) applications. Two types of zirconium-based MOFs, Zr-BADS-1 and Zr-BADS-2, were synthesized via a solvothermal method using bicinchoninic acid disodium salt as a linker and either dimethylformamide or ethanol as solvent, respectively. TFN membranes were prepared by embedding these MOFs within the polyamide thin film supported by a polysulfone support sheet. The specific surface area of Zr-BADS-1 and Zr-BADS-2 was determined to be 396.1 and 278.6 m2/g, respectively, indicating significant surface area conducive to water permeation. Scanning electron microscopic analysis r
... Show MoreAbstract In this paper, the researcher accounts for two different points of view concerning the tense of infinitive clauses in English language when functioning as verb complementation, and explains their bases and justifications. Some grammarians postulate that infinitive clauses complementation are tensed clauses, having the feature tense , since they, sometimes, indicate time relations different from that of the matrix clause, while most grammarians and linguists say that infinitive clauses, in their two types- 'to'- infinitives and bare infinitives, are tenseless clauses; they are nonfinite clauses. Grammarians state that infinitive clauses functioning as verb complementation are tensed clauses due to the presence of some temp
... Show MoreTranslating poetry is considered one of the most complicated types of translations. It
encounters many difficulties, the most important of which is the question of possibility or
impossibility of translating poetry. So, it is better to start by asking the following question: is
the translation of poetry possible? Or is it impossible? It is definitely a rhetorical question
because translation is as old as the presence of translated texts, which fills the shelves of
libraries. One can ask despite these difficulties, who would discourage people of the world
from translating poetry merely because it is fundamentally impossible? (Mann, 1970: 211)
The present paper will elaborate, in more detail, upon the necessary traits
Background:Hydrocephalus is dilatation of the ventricular system due to excessive production and/ or obstruction of cerebrospinal fluid (CSF) pathways. Different surgical procedure are used to treat this disease. Ventriculo peritoneal shunt is by far the most popular technique for CSF diversion..
Objective;To compare the programmable and non-programmable valves regarding the complications of both types
Methods:This study was conducted in the Neurosurgical hospital of Baghdad/Iraq over a period of 3 years from July 2008 to August 2011.
A special inclusion criteria has been tabulated for the selection of patients..
Results:.Fifty cases with hydrocephalus admitted and diagnosed by CT scan and treated by ventriculoperitoneal shun
The moisture sorption isotherms of Mefenamic acid tablets were investigated by measuring the experimental equilibrium moisture content (EMC) using the static method of saturated salt solutions at three temperatures (25, 35, and 45°C) and water activity range from 0.056 to 0.8434. The results showed that EMC increased when relative humidity increased and the sorption capacity decreased, the tablets became less hygroscopic and more stable when the temperature increased at constant water activity. The sorption curves had a sigmoid shape, type II according to Brunauer’s classification. The hysteresis effect was significant along with the whole sorption process. The results were fitted to three models: Oswin, Smith, and Guggen
... Show More