Preferred Language
Articles
/
lRdcUZABVTCNdQwCZ4ZC
Multipole Mixing Ratios of Gamma Rays From Fe(n,ny Reaction Using Constant Statistical Tensor Method (CST).
...Show More Authors

The - M ultiple mixing ratios of -transitions from levels of 56Fe populated in 56 56 Fe n n Fe ( , )  reactions are calculated by using const. S.T.M. This method has been used in other works [3,7] but with pure transition or with transitions that can be considered as pure transitions، in our work we used This method for mixed  - transitions in addition to pure  - transitions. The experimental angular distribution coefficients a2 was used from previous works [1] in order to calculet - values. It is clear from the results that the - values are in good agreement or consistent, within associated errors, with those reported previously [1]. The discrepancies that occur are due to inaccuracies existing in the experimental data of the previous works. The present work results confirm the validities of C.S.T.M. in calculating the -mixing ratios and their capabilities in predicting any inaccuracy in the experimental data and C.T.T.M. for mixed transition which are better than C.T.T.M. for pure transitions because it depends only on the experimental results while the 2nd method depends on pure and that which can be considered to be pure transitions.

Publication Date
Sun Mar 05 2017
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Bisacodyl in Pure and Pharmaceutical Preparation via Oxidative Coupling Organic Reaction
...Show More Authors

A simple, accurate and sensitive spectrophotometric way is used to determine Bisacodyl in pure and pharmaceutical preparations. The proposed method depends on using 2,4-Dinitrophenylhydrazine as chromogenic reagent . The method was based on the oxidative coupling reaction of Bisacodyl with 2,4-Dinitrophenylhydrazine with Sodium periodate in the presence of sodium hydroxide as alkaline media to form red water soluble dye product , that has a maximum absorption at ?max 522nm . Beer ,s law is obeyed in the concentration of (2.00–20.00) ?g.ml -1 .The molar absorptivity is (6505) L.mol-1.cm-1,a sandall sensitivity of(0.0555) ?g.cm-2), correlation coefficient of (0.9970) , Limitof detection (LOD) (0.0312 ?g.ml-1), limit of Quantitation (LOQ) (

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (1)
Scopus Crossref
Publication Date
Sat Mar 01 2025
Journal Name
Journal Of Ecological Engineering
Synthesis of sulfated zirconia-HY zeolite catalysts doped by platinum metal for hydroisomerization reaction
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Thu Jun 30 2022
Journal Name
International Journal Of Drug Delivery Technology
Synthesized Zinc Oxide Nanoparticles by The Precipitation Method on Streptococcus Spp From Dental Carries and Cytotoxicity Assay
...Show More Authors

In this article the nanoparticles synthesis of ZnO (Nps) by using the precipitation method at concentrations range (0.5, 0.25, 0.125, 0.0625, 0.03125) mg/mL and then activity was examined against Streptococcus spp that causing dental caries in vitro by well diffusion method, find these concentrations effected in these bacteria and better concentration is 0.03125. ZnO Nps were characterization by EDS to prove this particles are ZnO, and also characterized by atomic force microscope (AFM), X-ray Diffraction (XRD) and TEM, from these technic found that the average size about 30.52 nm and hexagonal shape. The UV-visible result reveals that the large band is observed at 340.8 nm, Zeta potential show that the surface charge is 30.19 mv an

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (2)
Scopus Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Positron Annihilation Lifetime Study on free Volume Changes in TLD by Gamma - irradiation
...Show More Authors

Positron annihilation lifetime has been utilized for the first time to investigate the free - volume hole properties in thermolumenscent dosimeter ( TLD ) as a function of gamma-dosc . The hole volume, free volume fraction determined form orthopsitronium lifetime are found to be ?lamatically increase to large values , and then to minimum values as a function ofgamma-dose . The free - volume holes size is found to be 0.163nm’ and to have maximum of 0.166nm^ at the gamma-dose of 0.1 and 0.8 Gy, respectively-

View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Materials Today: Proceedings
Synthesis of gamma biguanides butyric acid analogues as HDAC inhibitors and studying their cytotoxic activity
...Show More Authors

View Publication
Scopus (8)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Wed Aug 26 2020
Journal Name
Iraqi Journal Of Agricultural Sciences
EFFECT OF GAMMA RADIATION AND ETHYL METHANESULFONATE (EMS) ON POTATO SALT STRESS TOLERANCE IN VITRO
...Show More Authors

An experiment was conducted in the Date Palm Research Units labs / College of Agricultural Engineering Sciences / University of Baghdad to assess the tolerance toward salinity stress in potato after two mutagens treatments in vitro. Potato cv. Arizona and Rivera nodal segments were irradiated with four dosages of gamma rays at 0, 10, 20, and 30 Gray and immersed in (EMS) with four concentrations included 0, 10, 20, and 30 mM. The survival rates after mutagenesis treatments were calculated and 449 lines were obtained. The lines were tested for salinity tolerance by growing in MS medium supplemented with four concentrations of NaCl at 0, 100, 150, and 200 mM and data were analyzed according to the CRD with 10 replicates and means were

... Show More
Scopus (11)
Crossref (3)
Scopus Crossref
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Gamma radiation induced changes in the optical properties of CdTe thin films for dosimetric purposes
...Show More Authors

The effect of 0.662MeV gamma radiation on the optical properties of the CdTe thin films was studied. 300nm thickness of CdTe samples were irradiated with doses (10, 20, 30,60krad) in room temperature. The absorption spectra for all the samples were recorded using UV- Visible spectrometer in order to calculate the energy gap, width of localized states and optical constants(refractive index, extinction coefficient, real and imaginary parts of dielectric constant). The optical energy gap was found to decrease from (1.53 to 1.48 eV), while the width of localized states increased from (1.34 to 1.49 eV) with the increasing of radiation dose. The behavior of energy gap with the irradiation dose makes the material a good candidate for dosimetry

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
The Effect of Fluorine and Hydrogen Concentrations on the Chain Reaction of HF Chemical Laser
...Show More Authors

A numerical investigation has been performed to examine the effect of fluorine concentration on the chain reaction mechanisms and parameters of hydrogen fluoride (HF) chemical laser. The practical difficulties associated with this type of lasers impose that an alternative route might be quite useful. Thus, particular attention was paid to develop a computer program to investigate various processes. The results of this computer simulation program proved their credibility when compared with the little published data. This computer program is called Reaction Rate Simulation Model (RRSM). An entirely new approach to emulate the reaction mechanisms has been followed. The effectiveness of reaction rates in the processes of HF lase

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Ieee Antennas And Wireless Propagation Letters
Stabilized and Fast Method for Compressive-Sensing-Based Method of Moments
...Show More Authors

View Publication
Scopus (12)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Sun Jun 03 2012
Journal Name
Baghdad Science Journal
On The Queuing System M/Er/1/N
...Show More Authors

In this paper the queuing system (M/Er/1/N) has been considered in equilibrium. The method of stages introduced by Erlang has been used. The system of equations which governs the equilibrium probabilities of various stages has been given. For general N the probability of j stages of service are left in the system, has been introduced. And the probability for the empty system has been calculated in the explicit form.

View Publication Preview PDF
Crossref