ST segment, T wave changes, QT interval changes, and QTc dispersion are among the parameters used to diagnose ischemic heart disease. The increase in the QT dispersion can be caused by myocardial ischemia, among other heart diseases, whereas cardiac diseases such as coronary artery disease (CAD) can be diagnosed by observing an abnormally high QTc dispersion. This study aimed to evaluate the variations in the QTc dispersion (depolarization and repolarization) of surface electrocardiography as a result of percutaneous coronary intervention (PCI) in patients with chronic total occlusion. This study took place in the Iraqi Center for Heart Disease from October 2020 to February 2021. 110 patients who suffered from chronic occlusion of the coronary artery and underwent PCI revascularization were examined. Twelve-lead electrocardiograms were recorded at the time of admission (12 hours before intervention) and more than one hour after the intervention. The measured ECG parameters included corrected QT interval durations and corrected QT dispersion in both pre and post-PCI electrocardiograms, and their values were compared. The average corrected QT interval and QTC dispersion changed significantly before and after the percutaneous coronary intervention. Performing percutaneous coronary intervention on patients who suffer from coronary artery total occlusion shows a major reduction in the corrected QT dispersion.
This paper aims to study the effect of circular Y-shaped fin arrangement to improve the low thermal response rates of a double-tube heat exchanger containing Paraffin phase change material (PCM). ANSYS software is employed to perform the computational fluid dynamic (CFD) simulations of the heat exchanger, including fluid flow, heat transfer, and the phase change process. The optimum state of the fin configuration is derived through sensitivity analysis by evaluating the geometrical parameters of the Y-shaped fin. For the same height of the fins (10 mm), the solidification time is reduced by almost 22%, and the discharging rate is enhanced by almost 26% using Y-shaped fins compared with the straight fins. The results demonstrate that the sol
... Show More<span lang="EN-US">The fundamental of a downlink massive multiple-input multiple-output (MIMO) energy- issue efficiency strategy is known as minimum mean squared error (MMSE) implementation degrades the performance of a downlink massive MIMO energy-efficiency scheme, so some improvements are adding for this precoding scheme to improve its workthat is called our proposal solution as a proposed improved MMSE precoder (PIMP). The energy efficiency (EE) study has also taken into mind drastically lowering radiated power while maintaining high throughput and minimizing interference issues. We further find the tradeoff between spectral efficiency (SE) and EE although they coincide at the beginning but later their interests become con
... Show MoreIn this study, the first kind Bessel function was used to solve Kepler equation for an elliptical orbiting satellite. It is a classical method that gives a direct solution for calculation of the eccentric anomaly. It was solved for one period from (M=0-360)° with an eccentricity of (e=0-1) and the number of terms from (N=1-10). Also, the error in the representation of the first kind Bessel function was calculated. The results indicated that for eccentricity of (0.1-0.4) and (N = 1-10), the values of eccentric anomaly gave a good result as compared with the exact solution. Besides, the obtained eccentric anomaly values were unaffected by increasing the number of terms (N = 6-10) for eccentricities (0.8 and 0.9). The Bessel
... Show MoreBackground: The rising rate of cesarean deliveries has generated concern about whether all procedures are medically justified. Limited data exist on how well first-time mothers understand the indications for their cesarean section in Iraq. Objective: To assess maternal knowledge of the medical reasons for the first cesarean delivery and its relationship with sociodemographic, obstetric, and neonatal characteristics. Methods: A cross-sectional study was conducted from October to December 2023 among 158 Iraqi women who underwent their first cesarean delivery. Data were collected using a structured, self-administered online questionnaire that assessed demographic, obstetric, and knowledge-related factors. Results: Less than half of the
... Show MoreAlloys from AgSb(SxSe1-x)2 with different compositions were prepared using quenching from the melt . This was done by put the appropriate amount of Ag, Sb,S and Se in an evaluated quartz ampoule , sealed and left at oven in temperature 1273 for 5 hours. Thin films with different composition were deposited by pulsed deposition technique PLD onto glass substrates at ambient temperature . This paper concerned on the investigate effect of composition on structural morphology, and electrical properties. The structure and morphology of the prepoared thin films were checked using X–ray diffraction and atomic force microscope. The D.C conductivity of the AgSb(SxSe1-x)2thin films with various x content was measured
... Show MoreWe studied the effect of certain environmental conditions for removing heavy metal elements from contaminated aqueous solutions (Cd, Cu, Pb, Fe, Zn, Ni, Cr) using the bacterium Bacillus subtilis to appoint the optimal conditions for removal ,The best optimum temperature range for two isolate was 30-35○C while the hydrogen number for the maximum mineral removal range was 6-7. The best primary mineral removal was 100 mg/L, while the maximum removal for all minerals was obtained after 6 hrs of Cu element time and the maximum removal efficiency was obtained after 24 hrs of Cu element. The results have proved that the best aeration for maximum removal was obtained at rotation speed of 150 rpm/minute. Inoculums of 5ml/100ml which contained 1
... Show MoreA Stereomicroscopic Evaluation of Four Endodontic Sealers Penetration into Artificial Lateral Canals Using Gutta-Percha Single Cone Obturation Technique, Omar Jihad Banawi*, Raghad
Experimental programs based test results has been used as a means to find out the response of individual elements of structure. In the present study involves investigated behavior of five reinforced concrete deep beams of dimension (length 1200 x height 300 x width150mm) under two points concentrated load with shear span to depth ratio of (1.52), four of these beams with hallow core and
retrofit with carbon fiber reinforced polymer CFRP (with single or double or sides Strips). Two shapes of hallow are investigated (circle and square section) to evaluated the response of beams in case experimental behavior. Test on simply supported beam was performed in the laboratory & loaddeflection, strain of concrete data and crack pattern of