Real Time Extended (RTX) technology works to take advantage of real-time data comes from the global network of tracking stations together with inventor locating and compression algorithms to calculate and relaying the orbit of satellite, satellite atomic clock, and any other systems corrections to the receivers, which lead to real-time correction with high accuracy. These corrections will be transferred to the receiver antenna by satellite (where coverage is available) and by IP (Internet Protocol) for the rest of world to provide the accurate location on the screen of smartphone or tablet by using specific software. The purpose of this study was to assess the accuracy of Global Navigation Satellite System (GNSS) low-cost external antenna and possibility for using it with a smartphone to measure the points in Real Time Kinematic (RTK) and (RTX) modes, obtaining the same accuracy by using high-cost (GNSS) receiver with same modes. The assessment has applied through comparing the control points measured in static mode (3 to 5 hours) and corrected by Online Positioning User Service (OPUS) web-based processing software with same control points measured in RTX mode by GNSS low-cost external antenna (5 minutes). The results of an assessment were obtained horizontal and vertical location error in real time, by receiver getting the RTX correction data over the satellite link were RMS (east 41cm, north 35 cm, elevation 94 cm), that means it’s more suitable for automotive, agriculture, and forestry application, As for the RTK mode, the comparison of the differences in RTK mode between the two antennas were RMS (north 5 cm, east 6 cm, elevation 10). This result indicates that the GNSS low-cost external antenna might be very useful in accurate surveying application.
Gaslift reactors are employed in several bioapplications due to their characteristics of cost-effectiveness and high efficiency. However, the nutrient and thermal gradient is one of the obstacles that stand in the way of its widespread use in biological applications. The diagnosis, analysis, and tracking of fluid paths in external draft tube gaslift bioreactor-type are the main topics of the current study. Several parameters were considered to assess the mixing efficiency such as downcomer-to-rizer diameter ratio (Ded/Dr), the position of the diffuser to the height of bioreactor ratio (Pd/Lr), and gas bubble size (Db). The multiple regression of liquid velocity indicates the optimal setting: Ded/Dr is (0.5), Pd/Lr is (0.02), and Db
... Show MoreGaslift reactors are employed in several bioapplications due to their characteristics of cost-effectiveness and high efficiency. However, the nutrient and thermal gradient is one of the obstacles that stand in the way of its widespread use in biological applications. The diagnosis, analysis, and tracking of fluid paths in external draft tube gaslift bioreactor-type are the main topics of the current study. Several parameters were considered to assess the mixing efficiency such as downcomer-to-rizer diameter ratio (Ded/Dr), the position of the diffuser to the height of bioreactor ratio (Pd/Lr), and gas bubble size (Db). The multiple regression of liquid velocity indicates the optimal setting: Ded/Dr is (0.5), Pd/Lr is (0.02), and Db
... Show MoreThis work concentrates on the effect of a flex-skin trailing edge flap on the aerodynamic characteristics of SD7037 airfoil at low Reynolds numbers, in the range of 2^10 to 5^10 using computational methods. The study used a range of angle of attack (AOA) associated with the take-off phase and different flap angles. The numerical model was set up in Siemens STAR-CCM+ package using the κ-ω shear stress transport turbulence model and the (γ-Reθ) transition model which ensured the approximate solution of Navier-Stokes equations. The verification of the computational solution was done by the comparison with the available experimental data of the plain flap, and it was discovered that the results matched pretty well at lower AoAs. Results in
... Show MorePVA, Starch/PVA, and Starch/PVA/sugar samples of different
concentrations (10, 20, 30 and 40 % wt/wt) were prepared by casting
method. DSC analysis was carried; the results showed only one glass
transition temperature (Tg) for the samples involved, which suggest
that starch/PVA and starch/PVA/sugar blends are miscible. The
miscibility is attributed to the hydrogen bonds between PVA and
starch. This is in a good agreement with (FTIR) results. Tg and Tm
decrease with starch and sugar content compared with that for
(PVA). Systematic decrease in ultimate strength, due to starch and
sugar ratio increase, is attributed to (PVA), which has more hydroxyl
groups that made its ultimate strength higher than that for
The administration on the basis of the activities designed to evaluate the performance of activities in terms of cost, time and quality by identifying activities that add value and those that are no add value and enables the administration of making up their own continuous improvement in production, through lower costs and reduce the time and improve the quality and reduce the incidence of spoilage and waste, y based search Ally premise that (the continuous improvement of the adoption of management style on the basis of the activities helps management in decision-making wise to reduce costs) to prove the hypothesis has sought research to achieve its goal of Alkadivh and Alkoppelan &nb
... Show MoreSamarium ions (Sm +3), a rare-earth element, have a significant optical emission within the visible spectrum. PMMA samples, mixed with different ratios of SmCl3.6H2O, were prepared via the casting method. The composite was tested using UV-visible, photoluminescence and thermogravimetric analysis (TGA). The FTIR spectrometry of PMMA samples showed some changes, including variation in band intensity, location, and width. Mixed with samarium decreases the intensity of the CO and CH2 stretching bands and band position. A new band appeared corresponding to ionic bonds between samarium cations with negative branches in the polymer. These variations indicate complex links between the Sm +3 ion and oxygen in the ether group. The optical absorption
... Show MoreBackground: It may be an important prospective clinical use of manufacturing of porous implant for clinical situations, such as cases of limitation in bone height, low bone density .The small segment of porous implant an effective osseointegration allows increasing in contact area provided for small segmented porous provided by its surface configuration. This study was done to Fabricate porous titanium implants by powder technology, as well as the observation of removal torque values of porous titanium implants compared to smooth titanium implants. Materials and methods: Twenty porous titanium implants (3.2mm in diameter and 8mm in length) were manufactured by powder technology using commercially pure titanium powder of ≤75um part
... Show MoreThe investment budget represents a stage of the investment decision in service units, and the preparation and implementation needs to be a complement of the same planning part, because the planning does not end with the development of the plan, but includes a follow-up implementation, so it has to be effective and efficient oversight of the estimates and procedures for disbursement of funds approved for investment projects, The problem with research in that local governments suffer from the presence of Allkaat and problems facing the implementation of the investment budget projects due to the adoption budget items which can not be measured the efficiency of the performance of these units of government by, and shortcomings in the control
... Show MoreThe aim of this study was spot light to the possibility of confection between hepatitis C&G viruses in Iraqi patients. The groups was studied included two groups as follow: 1- first group: its (Infected group) the patients of this group have Anti-HCV abs in their serum by using Indirect ELISA technique. 2- second group: its (Control group) the persons of this group have no Anti-HCV abs in their serum by using indirect ELISA technique. The result of this study was observed there was two patients from the first group have Anti-HGVabs in their serum with infection percent 2.70%, also the same result was found in the second group wich mean there was two persons have Anti-HGVabs in their serum with infection percent 8.33% .So when we comparin
... Show More