Background: In young adults, multiple sclerosis is a prevalent chronic inflammatory demyelinating condition. It is characterized by white matter affection, but many individuals also have significant gray matter involvement. A double-inversion recovery pulse (DIR) pattern was recently proposed to improve the visibility of multiple sclerosis lesions. Objective: To find out how well a DIR sequence, FLAIR, and T2-weighted pulse sequences can find MS lesions in the supratentorial and infratentorial regions. Methods: A total of 37 patients with established diagnoses of multiple sclerosis were included in this cross-sectional study. Brain MRI was done using double inversion recovery, T2, and FLAIR sequences. The number of lesions was counted and compared in the three sequences. Results: The DIR sequence detected more infratentorial lesions when compared to the T2 and FLAIR sequences. In the supratentorial region, DIR detected more lesions than T2 and FLAIR. Conclusion: The DIR sequence is highly superior to both the T2 and FLAIR sequences in depicting the lesions, regardless of their anatomical distribution. Moreover, the DIR sequence detected more multiple sclerosis lesions in the infratentorial region than the traditional T2W and FLAIR sequences.
Background: Fibromyalgia syndrome (FMS) is the
most common rheumatic cause of diffuse pain and
multiple regional musculoskeletal pain and disability.
Objective: is to assess the contribution of serum
lipoprotein (A) in the pathogenesis of FMS patients.
Methods: One hundred twenty two FMS patients
were compared with 60 healthy control individuals
who were age and sex matched. All FMS features and
criteria are applied for patients and controls; patients
with secondary FMS were excluded. Serum
Lipoprotein (A): [Lp(A)], body mass index (BMI), &
s.lipid profile were determined for both groups.
Results: There was a statistical significant difference
between patients &controls in serum lipoprotein
Metal-organic frameworks (MOFs) have emerged as revolutionary materials for developing advanced biosensors, especially for detecting reactive oxygen species (ROS) and hydrogen peroxide (H₂O₂) in biomedical applications. This comprehensive review explores the current state-of-the-art in MOF-based biosensors, covering fundamental principles, design strategies, performance features, and clinical uses. MOFs offer unique benefits, including exceptional porosity (up to 10,400 m²/g), tunable structures, biocompatibility, and natural enzyme-mimicking properties, making them ideal platforms for sensitive and selective detection of ROS and H₂O₂. Recent advances have shown significant improvements in detection capabilities, with limit
... Show MoreRecurrent respiratory tract infections are responsible for about 85% of all diseases in childhood, and are associated with significant morbidity and mortality. The aim of this study is to evaluate the main causes underlying recurrent respiratory tract infections in 176 pediatric patients aged 2 month to 4 year and weight from 4 to11 kg referred to the child center hospital and Al-sader hospital prospective study.All parents were given information sheet which then analyzed and the percentage of incidence of causes were recorded, we found that higher % related to many causes; mostly related to the parent like poor family education, mother carelessness, incomplete vaccination, other related to empirical diagnosis, and short course of t
... Show MoreThis work focused on principle of higher order mode excitation using in- line Double Clad Multi-Mode Mach-Zehnder Interferometer (DC-MM-MZI). The DC-MM-MZI was designed with 50 cm etched MMF. The etching length is 5cm. The tenability of this interferometer was studied using opt grating ver.4.2.2 and optiwave
ver. 7 simulator. After removing (25, 35, 45, 55) μm from MMF and immersing this segment of MMF with water bath contained distilled water and ethanol, in addition to, air. Pulsed laser source centered at 1546.7nm ,pulse width 10ns and peak power 1.33mW was propagated via this interferometer Maximum modes were obtained in case of air surrounded media which are 9800 and 25 um removed cladding layer, with peak power 49.800 m
This study focuses on CFD analysis in the field of the shell and double concentric tube heat exchanger. A commercial CFD package was used to resolve the flow and temperature fields inside the shell and tubes of the heat exchanger used. Simulations by CFD are performed for the single shell and double concentric tube.
This heat exchanger included 16 tubes and 20 baffles. The shell had a length of 1.18 m and its diameter was 220 mm. Solid Works 2014, ANSYS 15.0 software was used to analyze the fields of flow and temperature inside the shell and the tubes. The RNG k-ε model was used and it provided good results. Coarse and fine meshes were investigated, showing that aspect ratio has no significant effect. 14 million
... Show MoreIn Iraq, because of the dramatic turnovers facing the country for three decades, pharmacists continue to experience significant professional challenges in both the public and private sectors. The present study aimed to explore the professional challenges and obstacles facing Iraqi pharmacists working in public hospitals. This qualitative study included face-to-face semi-structured interviews with open-ended questions with hospital pharmacists. The participants were selected purposefully (with ≥ 3 years of experience) to work at governmental hospitals in Karbala province between December 2022 and April 2023. The audio-recording interviews were scripted. Thematic analyses were used to generate themes and subthemes from the interview
... Show More