The use of performance measures modern and sophisticated one of the most important factors that help organization management in achieving customer satisfaction which today is the premise of The scales cell performance and value stream performance measures that will help organization management elimination of waste in all its forms, by allowing the organization opportunities and strengths to help them in achieving their goals. as well as achieving market share and growth in sales and increase cash inflows Where research deals with the concept of lean performance and managerial and its measurement and the evolution of these measure, and the ability of these organizations to achieve customer satisfaction through the application of these modern measure.
AS Muhsen, International Journal of Psychosocial Rehabilitation (1475-7192), 2020 - Cited by 1
This work presents the modeling of the electrical response of monocrystalline photovoltaic module by using five parameters model based on manufacture data-sheet of a solar module that measured in stander test conditions (STC) at radiation 1000W/m² and cell temperature 25 . The model takes into account the series and parallel (shunt) resistance of the module. This paper considers the details of Matlab modeling of the solar module by a developed Simulink model using the basic equations, the first approach was to estimate the parameters: photocurrent Iph, saturation current Is, shunt resistance Rsh, series resistance Rs, ideality factor A at stander test condition (STC) by an ite
... Show MoreMassive multiple-input multiple-output (massive-MIMO) is considered as the key technology to meet the huge demands of data rates in the future wireless communications networks. However, for massive-MIMO systems to realize their maximum potential gain, sufficiently accurate downlink (DL) channel state information (CSI) with low overhead to meet the short coherence time (CT) is required. Therefore, this article aims to overcome the technical challenge of DL CSI estimation in a frequency-division-duplex (FDD) massive-MIMO with short CT considering five different physical correlation models. To this end, the statistical structure of the massive-MIMO channel, which is captured by the physical correlation is exploited to find sufficiently
... Show MoreThe current study performed in order to detect and quantify epicatechin in two tea samples of Camellia sinensis (black and green tea) by thin layer chromatography (TLC) and high performance liquid chromatography (HPLC). Extraction of epicatechin from black and green tea was done by using two different methods: maceration (cold extraction method) and decoction (hot extraction method) involved using three different solvents which are absolute ethanol, 50% aqueous ethanol and water for both extraction methods using room temperature and direct heat respectively. Crude extracts of two tea samples that obtained from two methods were fractionated by using two solvents with different polarity (chloroform and
... Show MoreThis study reports testing results of the transient response of T-shape concrete deep beams with large openings due to impact loading. Seven concrete deep beams with openings including two ordinary reinforced, four partially prestressed, and one solid ordinary reinforced as a reference beam were fabricated and tested. The effects of prestressing strand position and the intensity of the impact force were investigated. Two values for the opening’s depth relative to the beam cross-section dimensions were inspected under the effect of an impacting mass repeatedly dropped from different heights. The study revealed that the beam’s transient deflection was increased by about 50% with gre
Nanocomposite films of silver-polyvinyl alcohol (Ag/PVA) with varying silver nanoparticle concentrations (1-5 wt%) were synthesized via a solution casting technique. The films were characterized by understanding the influence of Ag content on their structural, optical, mechanical, and electrical properties. UV-Vis spectroscopy (300-800 nm) revealed a red shift in absorption peaks and a significant decrease in the optical band gap from 5.39 eV to 1.06 eV with increasing Ag concentration, indicating the formation of additional energy states within the PVA matrix. FTIR and SEM analyses confirmed the successful incorporation of nanoparticles and revealed changes in surface functionalities and morpholog
This paper presents a brief study undertaken for improving the performance of information and communication management of construction projects through investing in information and communication technologies (ICT). The work aims at first to investigate and diagnose the problems, challenges, weaknesses, and inefficiencies related to information and communication management in projects in the construction industry of Iraq. Studying the diagnosed matters and the different solutions of ICT to improve project management performance is following the investigation process. The research presents a technological system suggested to process a lot of the diagnosed problems, challenges, weakness, and inefficiencies of the construction projects and t
... Show MorePressure ulcers are one of the most common hospital-acquired major conditions that occur in patients with mobility limitations and result in endangering patient safety, prolonging hospital stay, disability, and death. This study aims to examine the level of nurses’ practices and perceived barriers for preventing pressure ulcers among critically ill patients.
A cross-sectional survey was conducte
The current study deals with the performance of constructed wetland (CW) incorporating a microbial fuel cell (MFC) for wastewater treatment and electricity generation. The whole unit is referred to as CW-MFC. This technique involves two treatments; the first is an aerobic treatment which occurs in the upper layer of the system (cathode section) and the second is anaerobic biological treatment in the lower layer of the system (anode section). Two types of electrode material were tested; stainless steel and graphite. Three configurations for electrodes arrangement CW-MFC were used. In the first unit of CW-MFC, the anode was graphite plate (GPa) and cathode was also graphite plate (GPc), in the second CW-MFC unit, the anode was stainless st
... Show More