This research investigates the importance of social accounting and the auditor’s report. It basically checks if there is an impact of social accounting on the auditor’s report at the availability the INTOSAI standards No. (1700 and 1706). The study recruited 105 employees of the Federal Financial Supervision Office in Iraq. Data were collected using questionnaire. The questionnaire validity and reliability were checked to assure the truthfulness of the findings. The study found a positive correlation and a statistically significant effect between the accounting for social responsibility and the auditor’s report. It is necessarily recommended for the auditor and the bodies working in the Board of Supreme Audit to ensure the inclusion of a paragraph that draws attention in the report prepared in accordance with the INTOSAI standards (1706) regarding the extent of adequate and appropriate disclosure of the social responsibility of the entities subject to audit.
الوصف The synthesis of 2 (N-phenyl dithio carboxamid) benzothiazol Ligand (L) from reaction of 2-Mercaptobenzothiozol with phenylisothiocyanate using ratio 1: 1. The ligand was characterized by elemental analysis (CHN),'H-NMR, IR and UV-Vis. The complexes with bivalent ions (Ni, Cu, Zn, Cd and Hg) have been prepared and characterized. The structural diagnosis was established using IR, UV–Visible spectro photometer, molar conductivity, atomic absorption and molar ratio with selected metal ions (Ni2+, Cu2+). The complexes of (Ni, Cu) gave octahedral structural while the complexes of (Zn, Cd, Hg) gave tetrahedral structural. The study of biological activity of the ligand (L) and its complexes (Ni, Cu, Hg) in two deferent concentration (
... Show MoreBackground: In recent years, the immediate loading of dental implants has become more accepted as a standard protocol for the treatment of the edentulous area. Success in implant dentistry depends on several parameters that may improve phenomenon of osseointegration and new bone formation in close contact with the implant. The aim of study was to evaluate the effect of strontium chloride coating of screw shape commercially pure titanium dental implant osseointegration at bone - implant interface by histomorphometric analysis and compare with hydroxyapatite coating at 2 time periods (2 weeks and 6 weeks). Materials and methods: Electrophoretic Deposition Technique (EPD) was used to obtain a uniform coating layer on commercially pure titanium
... Show MoreThis study was design to investigate the dimensional stability of heat-activated acrylic resin with different methods of flask cooling (15 minutes rapid cooling, one hour bench cooling, four hours delayed deflasking, and 24 hours delayed deflasking) at different time intervals (immediately, two days, seven days, 30 days) after deflasking. Heat-activated acrylic resin was used to prepare acrylic samples. Then, measurement of the distances where achieved between the centers of selected marks in the acrylic samples. They were measured at different time intervals for different methods of flask cooling. The results showed that the group samples of the four hours and 24 hours of delayed deflasking was insignificantly different from the control an
... Show MoreAbstract. This work presents a detailed design of a three-jointed tendon-driven robot finger with a cam/pulleys transmission and joint Variable Stiffness Actuator (VSA). The finger motion configuration is obtained by deriving the cam/pulleys transmission profile as a mathematical solution that is then implemented to achieve contact force isotropy on the phalanges. A VSA is proposed, in which three VSAs are designed to act as a muscle in joint space to provide firm grasping. As a mechatronic approach, a suitable type and number of force sensors and actuators are designed to sense the touch, actuate the finger, and tune the VSAs. The torque of the VSAs is controlled utilizing a designed Multi Input Multi Output (MIMO) fuzzy controll
... Show More