Preferred Language
Articles
/
jperc-1486
The Effectiveness of a Program in Developing Awareness of the Criteria for Judging Electronic Educational Materials Among Students of Teaching Diploma at Dhofar University
...Show More Authors

The study aims to develop the awareness of the criteria for judging electronic educational materials among students of educational qualification at Dhofar University over spreading the Corona pandemic through a program based on mini-educational units. The study was applied to (18) students studying Teaching diploma at Dhofar University for the academic year 2020-2021, and their number. They were chosen intentionally. The study resulted in reaching a list of criteria for judging electronic educational materials, roughly (18) criteria in the selection themes and (15) criteria in the use theme. The level of awareness of the sample members with the criteria for selecting and using electronic educational materials and the effectiveness of the program in increasing awareness of students with standards recorded low levels. The study came out with a set of recommendations: holding training courses for students of the Teaching diploma and student teachers in the various disciplines of education through adopting the current criteria. Including these criteria through studying the educational teaching diploma and the bachelor of education. Adopting the current program in all disciplines in the department of education. Thus, we can make good use of it in light of the Corona pandemic.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Oct 20 2023
Journal Name
Baghdad Science Journal
Synthesis, Characterization , Thermal Studies and Antioxidant Activities of Transition Metal Complexes with Azo Dye ligand
...Show More Authors

Diazotization reaction between 1-(2,4,6-Trihydroxy-phenyl)-ethanone and diazonium salts was carried out resulting in ligand 4-(3-Acetyl-2,4,6-trihydroxy-phenylazo)-N-(5-methyl-isoxazol-3-yl)-benzenesulfonamide, this in turn reacted with the next metal ions (V4+ , Cr3+ , Mn2+ and Cu2+) forming stable complexes with unique geometries such as (Octahedral for both Cr3+ , Mn2+ and Cu2+ ,squar pyramidal for V4+). The creation of such complexes was detected by employing spectroscopic means involving ultraviolet-visible which proved the obtained geometries, fourier transfer proved the formation of azo group and and the coordination with metal ion through it. Pyrolysis (TGA & DSC) studies proved the coordination of water residues with me

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Mar 23 2023
Journal Name
Arab Gulf Journal Of Scientific Research
Influence pH on virulence genes of <i>Pseudomonas aeruginosa</i>analyzed by RT-PCR method
...Show More Authors
Purpose

The purpose of this study was to determine the influence of environmental pH on production of biofilms and virulence genes expression in Pseudomonas aeruginosa.

Design/methodology/approach

Among 303 clinical and environmental samples 109 (61 + 48) isolates were identified as clinical and environmental P. aeruginosa isolates, respectively. Clinical samples were obtained from patients in the Al-Yarmouk hospital in Baghdad city, Iraq. Waste water from Al-Yarmouk hospital was used from site before treatment unit to collect environmental samples. The ability of prod

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Journal Of Engineering
Improve Rheological Properties of Palygorskite Water-Based Drilling Fluid by Caustic Soda and Soda Ash
...Show More Authors

In drilling fluid program, selecting the drilling fluid that will reduce the lost time is the first objective, and will be economical regardless of its cost. The amount and type of solids in drilling fluid is the primary control of the rheological and filtration properties. Palygorskite clay (attapulgite) is an active solid that has the ability to reactive with its environment and form a gel structure within a fluid and due to its stability in the presence of brines and electrolytes this type of clay is preferred for use. The aim of this study is to improve properties of Iraqi palygorskite (PAL) by adding different chemical additives such as caustic soda NaOH and soda ash Na2CO3 with a different con

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
DESIGN, CONSTRUCTION AND TESTING OF LOW SPEED WIND TUNNEL WITH ITS MEASUREMENT AND INSPECTION DEVICES
...Show More Authors

A low speed open circuit wind tunnel has been designed, manufactured and constructed at the
Mechanical Engineering Department at Baghdad University - College of Engineering. The work is one of
the pioneer projects adapted by the R & D Office at the Iraqi MOHESR. The present paper describes the
first part of the work; that is the design calculations, simulation and construction. It will be followed by a
second part that describes testing and calibration of the tunnel. The proposed wind tunnel has a test
section with cross sectional area of (0.7 x 0.7 m2) and length of (1.5 m). The maximum speed is about (70
m/s) with empty test section. The contraction ratio is (8.16). Three screens are used to minimize flow
distu

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Wed Dec 25 2019
Journal Name
Journal Of Engineering
Corrosion Rate Optimization of Mild-Steel under Different Cooling Tower Working Parameters Using Taguchi Design
...Show More Authors

This study investigates the implementation of Taguchi design in the estimation of minimum corrosion rate of mild-steel in cooling tower that uses saline solution of different concentration. The experiments were set on the basis of Taguchi’s L16 orthogonal array. The runs were carried out under different condition such as inlet concentration of saline solution, temperature, and flowrate. The Signal-to- Noise ratio and ANOVA analysis were used to define the impact of cooling tower working conditions on the corrosion rate. A regression had been modelled and optimized to identify the optimum level for the working parameters that had been founded to be 13%NaCl, 35ᴼC, and 1 l/min. Also a confirmation run to establish the p

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Sun Oct 01 2023
Journal Name
Egyptian Journal Of Immunology
Assessment of chemokines MIP-1α and MIP-1 βin Iraqi women with polycystic ovarian syndrome
...Show More Authors

Polycystic ovary syndrome (PCOS) is reproductive, endocrine, and metabolic disorder affecting females. The pathology of PCOS is complicated and associated to chronic low-grade inflammation, this includes a disruption in pro-inflammatory factor production, leukocytosis, and endothelial cell dysfunction, also associated with high level of pro-inflammatory cytokines, chemokines and leukocyte count. In addition, PCOS is characterized by hormonal and immunological dysfunction. Inflammation of the ovary affects ovulation and induces or aggravates systemic inflammation. Macrophage inflammatory protein-1 (MIP-1), a pro-inflammatory chemokine, is crucial in the recruitment of inflammatory and immunological cells to the place of inflammation

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Mon Jun 05 2023
Journal Name
Journal Of Engineering
Adsorption of Chromium (Vi) from Aqueous Solutions using Low Cost Adsorbent: Equilibrium and Regeneration Studies
...Show More Authors

The adsorption of Cr (VI) from aqueous solution by spent tea leaves (STL) was studied at different initial Cr (VI) concentrations, adsorbent dose, pH and contact time under batch isotherm experiments The adsorption experiments were carried out at 30°C and the effects of the four parameters on chromium uptake to establish a mathematical model description percentage removal of Cr (VI). The
analysis results showed that the experimental data were adequately fitted to second order polynomial model with correlation coefficients for this model was (R2 = 0.9891). The optimum operating parameters of initial Cr (VI) concentrations, adsorbent dose, pH and contact time were 50 mg/l, 0.7625 g, 3 and 100 min, respectively. At these conditions, th

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Materials Today: Proceedings
Experimental and theoretical investigations of seepage reduction through zoned earth dam material with special core
...Show More Authors

View Publication
Scopus (15)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Wed Nov 01 2017
Journal Name
Journal Of Engineering
Performance evaluation of Sequencing Batch Reactor and Conventional Wastewater Treatment Plant based on Reliability assessment
...Show More Authors

Baghdad city has been faced numerous issues related to freshwater environment deteriorations due to many reasons, mainly was the discharge of wastewater without adequate treatment. Al- Rustamiya Wastewater Treatment Plant (WWTP) have been constructed among many plants in Baghdad city to reduce the amount of wastewater discharged into natural environment and its subsequent adverse effects. This study was conducted to evaluate the performance of the plant which consist of a conventional activated sludge (CAS) and sequencing batch reactors (SBR) systems as secondary treatment units and its ability to meet Iraqi specifications. A reliability level determination and analysis also were conducted to find the plant's stability and its capabi

... Show More
Publication Date
Sun Dec 01 2019
Journal Name
Civil Engineering Journal
Structural Behavior of High Strength Laced Reinforced Concrete One Way Slab Exposed to Fire Flame
...Show More Authors

In this study, an experimental investigation had conducted for six high strength laced reinforced concrete one-way slabs to discover the behavior of laced structural members after being exposed to fire flame (high temperature). Self-compacted concrete (SCC) had used to achieve easy casting and high strength concrete. All the adopted specimens were identical in their compressive strength of ( , geometric layout 2000 750 150 mm and reinforcement specifics except those of lacing steel content, three ratios of laced steel reinforcement of (0.0021, 0.0040 and 0.0060) were adopted. Three specimens were fired with a steady state temperature of  for two hours duration and then after the specimens were cooled suddenly by spraying water. The

... Show More
View Publication
Crossref (5)
Crossref