The current study examined the effect of different sample sizes to detect the Item differential functioning (DIF). The study has used three different sizes of the samples (300, 500, 1000), as well as to test a component of twenty polytomous items, where each item has five categories. They were used Graded Response Model as a single polytomous item response theory model to estimate items and individuals’ parameters. The study has used the Mantel-Haenszel (MH) way to detect (DIF) through each case for the different samples. The results of the study showed the inverse relationship between the sample size and the number of items, which showed a differential performer.
This research amid to measure the impact of organizational flexibility (structural flexibility, operational flexibility, and strategic flexibility) in achieving organizational prosperity and its dimensions (strategic agility, intellectual capital, innovation and sustainable competitive advantage) in a number of Iraqi cellular communications companies. The research adopted descriptive analytical approach. A sample of (85) persons from the research community was selected, which included (Department managers, Directors administrative units, Communication engineers), to answer the questionnaire prepared for this purpose. And to analyze data and derive results. Statist
... Show MoreAbstract: Stars whose initial masses are between (0.89 - 8.0) M☉ go through an Asymptotic Giant Branch (AGB) phase at the end of their life. Which have been evolved from the main sequence phase through Asymptotic Giant Branch (AGB). The calculations were done by adopted Synthetic Model showed the following results: 1- Mass loss on the AGB phase consists of two phases for period (P <500) days and for (P>500) days; 2- the mass loss rate exponentially increases with the pulsation periods; 3- The expansion velocity VAGB for our stars are calculated according to the three assumptions; 4- the terminal velocity depends on several factors likes metallicity and luminosity. The calculations indicated that a super wind phase (S.W) developed on the A
... Show MoreSemiconductor-based metal oxide gas detector of five mixed from zinc chloride Z and tin chloride S salts Z:S ratio 0, 25, 50, 75 and 100% were fabricated on glass substrate by a spray pyrolysis technique. With thickness were about 0.2 ±0.05 μm using water soluble as precursors at a glass substrate temperature 500 ºC±5, 0.05 M, and their gas sensing properties toward CH4, LPG and H2S gas at different concentration (10, 100, 1000 ppm) in air were investigated at room temperature which related with the petroleum refining industry.
Furthermore structural and morphology properties were scrutinize. Results shows that the mixing ratio affect the composition of formative oxides were (ZnO, Zn2SnO4, Zn2SnO4+ZnSnO3, ZnSnO3, SnO2) ratios ment
Chronic renal failure (CRF) affects thyroid function in multiple ways, including low circulating thyroid hormone concentration, altered peripheral hormone metabolism, disturbed binding to carrier proteins, possible reduction in tissue thyroid hormone content, and increased iodine store in thyroid glands.The target of study is to find a relationship between chronic renal failure and thyroid function.In addition, we tried to study the effect of CRF on serum creatinine dependent on the level of thyroid hormones (T3 and T4) and thyroid stimulating hormones(TSH). Forty patients with chronic renal failure (20 male, 20 female) were enrolled in this study in addition to forty healthy individual as control gro
... Show MoreThe recent studies suggested the possible toxicities or genetic alterations associated with biological and medical applications of silver nanoparticles (AgNPs). The current research is directed to see if AgNPs administration can lead to some changes in expression of BRAF gene in selected body organs tissues. Fifty-six male of musmusculs (Balb/C) mice from the animal house of Al-Nahrain Centre of Biotechnology were used. These animals were divided randomly to seven groups (eight mouse in each group), one of these groups represented the control group, three groups were subjected to different doses of AgNPs (0.25, 0.5and 1 mg/kg of body weight) for one week, and the remaining three groups were subjected to three different doses of AgNP
... Show MoreThe activation energy and optical band gap of different regions (p-type) polysilicon have been measured. Both microscopic studies and current-voltage characteristics of diodes prepared on different surface regions were carried out. Comparison of diodes parameters and microscopic studies indicate that the type of angles between boundaries has a significant effect on diodes parameters while the boundary lengths per unit area has less effect. The mechanism of Al-interaction with grain boundaries and their intersecting points at different temperature were also studies. The X-ray fluorescence spectrometry has been used for detection of diffused A1%.
Chemical spray pyrolysis technique was used at substrate temperature 250 ˚C with annealing temperature at 400 ˚C (for 1hour) to deposition tungsten oxide thin film with different doping concentration of Au nanoparticle (0, 10, 20, 30 and 40)% wt. on glass substrate with thickness about 100 nm. The structural, optical properties were investigated. The X-ray diffraction shows that the films at substrate temperature (250 ˚C) was amorphous while at annealing temperature have a polycrystalline structure with the preferred orientation of (200), all the samples have a hexagonal structure for WO3 and Au gold nanoparticles have a cubic structure. Atomic force microscopy (AFM) was used to characterize the morphology of the films. The optical pr
... Show MoreAim: This study aimed to compare different types of ligation methods to obtain maximum tooth movement with the least undesirable rotation. Methods: Titanium brackets bonded to acrylic canine teeth were ligated to straight stainless steel (SS) archwires using four ligation methods (figure-O and figure-8 elastics, SS ligatures, and Leone Slide ligatures). The teeth with the ligatures in place were stored in a water bath at 37ºC for 1 day, 1 week, 2, 4 or 6 weeks before testing. The teeth were retracted through softened wax along the archwire and the amount of tooth movement and degree of rotation were measured. Results: Slide ligatures showed the highest distance of tooth movement and degree of canine rotation followed by figure-O elastics
... Show More