This research aims to identify the effect of numbered heads strategy on developing oral expression skills among fifth-grade primary students in Bisha Province. To achieve this, the researcher prepared a research tool represented in the observation card which consists of (27) statements distributed in four axes. The tool was sent to (5) experts in the field to verify their validity. In light of their corrections, the tool was developed to be valid for gathering field information. To verify the validity of the content and the reliability of the tool, the researcher applied it to a sample consists of (20) students from outside the research group. The overall coefficient of correlation between the statements of the tool is as follows: (.95, .93, .87, .88). The researcher also made an equation (Alpha Cronbach). The reliability of the tool was ranged between (0.72, - 0.86) at the level of the four tool axes, it was reached at the level of the tool as a whole (0.94), which indicates that the tool is of a high degree of reliability, and the results of the research can be trusted on. The research was applied in the field at Al-Rafaya School, one of the primary schools, which belongs to the Central Education Office in Bisha Province, during the first term of the year 1440/1441 H. After applying the tool and analyzing its data, the results revealed a statistically significant difference at the significance level (0.01) between the average of the experimental group scores and the control group, in favor of the experimental group in oral expression skills in the four tool axes. The researcher used the Cohen equation to calculate the effect size. The results revealed that the value of (Z) is ranged from (3.80 to 4.50) between the control and experimental research group; all of them are significant values at the level of significance (0.01) according to Cohen's equation. The findings resulted in the positive impact of the numbered head strategy among the experimental research group in developing their oral expression skills, where the positive ranks were greater than the negative ranks in all research axes. In light of these results, the researcher presented a set of recommendations.
Diabetes mellitus (DM) has been defined as a clinical syndrome that is characterized by abnormal carbohydrate metabolism. The chronic hyperglycemia of diabetes is associated with long term damage, dysfunction, and failure of different organs, especially the liver .This study was conducted to assess the effect obesity and insulin resistance on liver enzymes in diabetic Iraqi patients.A comparative study of (90) Iraqi adults divided to three subgroup(30) obese ,(30) nonobese diabetic patients and(30)person had used as control. The analysis included Liver enzyme ALP,ALT,AST,GGT ,Fasting Plasma Glucose (FBG) , Lipid Profile , Hemoglobin A1C , insulin and homeostasis model assessment of insulin resistance (HOMA IR) were measured. Subjects
... Show MoreThe present research has investigated the effect of microwave energy on improving the flow properties of heavy crude oil. The fragmentation of crude oil molecules was carried out with and without using 1 and 10 wt. % concentration of various types of H-donors like tetralin, cyclohexane, and naphtha. Microwave power of 320, 385, and 540 W and radiation time 1-9 min, and temperature were studied. The kinematic viscosity and asphaltene content were measured for evaluation the improving of heavy crude oil.
Results show that viscosity of crude oil decreased with increase H-donor concentration, a maximum percentage of viscosity reduction was10.63 % for tetralin at 6 min radiation time, while 8.67%, and 7.34% for cycl
... Show MoreBackground: The aims of this study were to evaluate the effect of implant site preparation in low-density bone using osseodensification method in terms of implant stability changes during the osseous healing period and peri-implant bone density using CBCT. Material and methods: This prospective observational clinical study included 24 patients who received 46 dental implants that were installed in low-density bone using the osseodensification method. CBCT was used to measure the bone density pre- and postoperatively and implant stability was measured using Periotest® immediately after implant insertion and then after 6 weeks and 12 weeks postoperatively. The data were analyzed using paired t-test and the probability value <0.05 was conside
... Show MoreBackground: This study aimed to assess the effect of tooth shape ratio on mandibular incisor arrangement. Materials and methods: The sample included dental casts of some dental students and orthodontic patients having Class I dental and skeletal patterns with normal occlusion and severe crowding. The sample was divided into two groups according to the severity of crowding into: group I had Class I normal occlusion with mild or no crowded mandibular dentition and group II had Class I malocclusion with severe crowded mandibular dentition. Each group comprising of 40 subjects (20 males and 20 females). The mesio-distal and facio-lingual crown diameters were measured manually for each cast using modified vernier caliper gauge. Descriptive sta
... Show MoreThe calculation of the charge on an isolated dust grain immersed in plasma with different grain sizes is a challenging one, especially under moderately high plasma temperature when secondary electron emission significant. The discrete charging model is used to calculate the charges of dust grain in dusty plasma. In this model, we included the effect of grain size dependence on secondary electron emission. The results show that the secondary electron emission from the glass dust grains due to energetic electron (40eV) can lead to the small grain to be slightly more positive than the large grain. Under these conditions, the smaller and larger grains would be attracted rather than repelled, which possibly lead to enhanced coagulation rates.
... Show MoreThis work reports the study of heat treatment effect on the structural, morphological, optical and electrical properties of poly [3-hexylthiophene] and its blend with [6,6]-phenyl C61 butyric acid methyl ester ( P3HT:PC61BM). X-ray diffraction (XRD) measurements show that the crystallinity of the films increased with annealing. The evaluation of surface roughness and morphology was investigated using atomic force microscope (AFM), and field emission scanning microscope(FESEM). The optical properties were emphasized a strong optical absorption of P3HT compared with the blend. Hall effect measurement was used to study the electrical properties which revealed there is an increase in the electrical conductivity and Hall mobility of th
... Show MoreRare earth elements (Cerium, Lanthanum and Neodymium) doped CdS thin films are prepared using the chemical Spray Pyrolysis Method with temperature 200 oC. The X-ray diffraction (XRD) analysis refers that pure CdS and CdS:Ce, CdS:La and CdS:Nd thin films showed the hexagonal crystalline phase. The crystallite size determined by the Debye-Scherrer equation and the range was (35.8– 23.76 nm), and it was confirmed by field emission scanning electron microscopy (FE-SEM). The pure and doped CdS shows a direct band gap (2.57 to 2.72 eV), which was obtained by transmittance. The room-temperature photoluminescence of pure and doped CdS shows large peak at 431 nm, and two small peaks at (530 and 610 nm). The Current – voltage measurement in da
... Show MoreObjectives: The study aims to investigate the efficiency of physiotherapy methods to improve the
degree of the clinical recovery of the peripheral facial palsy.
Methodology: This study is carried out at the Rehabilitation Center-Baghdad from November 2009 till
March 2010. This study includes (40) patient, their ages are from (13) to (55) years old; (24) male and
(16) female with unilateral facial palsy of undetermined cause. House-Brackmann facial recovery
scores have been used before and after the physiotherapy treatment.
Results: The results show that the physiotherapy sessions obtained the best effect of the electrical
stimulation, exercises and massage in the treatment of facial palsy. Highly respondents in femal
Zinc sulfide (ZnS) thin films were deposited on glass substrates using pulsed laser deposition technique. The laser used is the Q-switched Nd: YAG laser with 1064nm wavelength and 1Hz pulse repetition rate and varying laser energy 700mJ-1000mJ with 25 pulse. The substrate temperature was kept constant at 100°C. The structural, morphological and optical properties of ZnS thin films were characterized with X-ray diffraction (XRD), scanning electron microscopy (SEM), atomic force microscope (AFM) and UV-VIS spectrophotometer.