the rationalization of energy consumption Require awareness in the possibility of bridging the local need severe shortage of electric power for daily requirements. The research aims to show that the engineers of various specializations and architects, including in particular can have an active role in about the importance of the role of energy in human life, and it’s best utilization without extravagance (which our religion forbids it). Here lies the problem of the research to find possible means and alternative methods to reduce (rationalization) electrical energy consumption in hot dry areas in general which need large energy for air conditioning because of the crucial climate of these regions that making access to the area of human thermal comfort is difficult, and especially in Iraq, as a result of suffering from constraints rationalizing the electric energy consumption, through the use of modern technologies that consistent with our environment, as well as traditional processors to limit the negative impact of climatic conditions on man’s thermal comfort. Based on the premise that there are planning methods related to the characteristics of the urban fabric and architectural solutions related to buildings design that can be used to reduce the negative impact of elements of the harsh climate in our hot dry regions and population access to thermal comfort without total reliance on artificial means of air conditioning. To achieve the goal of the research and make sure of his hypothesis, The research methodology have been based on the collection of theoretical information of climate elements and put some of the methods and processes used in urban planning and buildings design with a direct impact on the characteristics of the urban fabric through which we can reduce the negative impact of climate in our hot dry regions . The practical part adopt the comparative analysis by choosing Al- Adhamiya city in Baghdad, which contain a traditional style with traditional solutions harmonious with our environment, and the modern style with transmitted processors that are often unfit with our environment
The -mixing of - transition in Er 168 populated in Er)n,n(Er 168168 reaction is calculated in the present work by using a2- ratio method. This method has used in previou studies [4, 5, 6, 7] in case that the second transition is pure or for that transition which can be considered as pure only, but in one work we applied this method for two cases, in the first one for pure transition and in the 2nd one for non pure transitions. We take into accunt the experimental a2- coefficient for p revious works and -values for one transition only [1]. The results obtained are, in general, in agood agreement within associated errors, with those reported previously [1], the discrepancies that occur are due to inaccuracies existing
... Show MoreThe present paper addresses cultivation of Chlorella vulgaris microalgae using airlift photobioreactor that sparged with 5% CO 2 /air. The experimental data were compared with that obtained from bioreactor aerated with air and unsparged bioreactor. The results showed that the concentration of biomass is 0.36 g l -1 in sparged bioreactor with CO2/air, while, the concentration of biomass reached to 0.069 g l -1 in the unsparged bioreactor. They showed also that aerated ioreactor.with CO2/air gives more biomass production even the bioreactor was aerated with air. This study proved that application of sparging system for ultivation of Chlorella vulgaris microalgae using either CO2/air mixture or air has a significant
... Show MoreChilled ceilings systems offer potential for overall capital savings. The main aim of the present research is to investigate the thermal performance of the indirect contact closed circuit cooling tower, ICCCCT used with chilled ceiling, to gain a deeper knowledge in this important field of engineering which has been traditionally used in various industrial & HVAC systems. To achieve this study, experimental work were implemented for the ICCCCT use with chilled ceiling. In this study the thermal performances of closed wet cooling tower use with chilled ceiling is experimentally and theoretically investigated. Different experimental tests were conducted by varying the controlling parameters to investigate their effects
... Show MoreMany isolated rural communities are located in regions where there is an abundant and reliable supply of solar energy, but where the distance to the nearest power station is many tens or even hundreds of kilometre. It is therefore mainly in these areas that rural electrification is now being provided by PV generators. since Stand-Alone PV generator can offer the most cost-effective and reliable option for providing power needed in remote places. Accordingly these isolated rural canters are fitted with PV for lighting, a refrigerator, a television and socket to supply kitchen appliances
تضمن هذا العمل تحضير ليكند قاعدة شيف جديدة مشتقة من مادة البولي أكريلاميد والكلوترالديهايد [(2S, 2'S) – N, N' - (pentane-1, 5-diylidene) bis (2- methylbutan amide)] مع بعض المعادن الثقيلة (Cr + 3 Mn + 3 , Fe + 3 , ,Co + 2, Ni + 2 ,Cu + 2 Zn + 2 , Cd + 2,) لتنتج المعقدات المقابلة. تم تشخيص قواعد شيف ومعقداتها المعدنية بأستخدام طيف الأشعة تحت الحمراء والأشعة المرئية وفوق البنفسجية، والتوصيلية ,وقيم المغناطيسية والتحليل الحراري الوزني وحيود الأشعة السينية ومجه
... Show MoreObjective(s): 1- Assess the effectiveness of health educational program on nurses' knowledge toward Hemodialysis at Pediatric Teaching Hospitals.
2-To find out the relationship between nurses' knowledge about hemodialysis and their demographic Characteristics.
Methods: The study was designed in a pre-experimental pattern for the nurses' working in the Child Welfare Teaching Hospital and the Child's Central Teaching Hospital, and a targeted sample consisting of (30) nurses was selected. It is tested in three periods of pre-test, the first post-test, and the second post-test. Participants were tested before implementing the tutorial (tutorial lectures
... Show MoreA fixed firefighting system is a key component of fire safeguarding and reducing fire danger. It is installed as a permanent component in a structure to protect the entire or a portion of the building and its contents. The study aims to review the previous studies that deal with the evaluation of fire safety measures and their use in resolving problems associated with fire threats in buildings. For this reason, a number of previous studies in this field were reviewed compared with the NFPA code. The findings revealed that regulatory developments over the last several decades had created an atmosphere conducive to innovation. This has resulted in a growth in the number of fixed firefighting system types now obtainable. Th
... Show MoreObjectives: To determine Smartphone addiction among primary school students and its impacts. The samples of the study were240primary school students in derived from stratified random sampling. The questionnaire was used to collect the data. The data were then an- analyzed using correlation statistics. It also caused a negative impact on demic performance of the primary school students.
Methodology: A cross- sectional study in assessment approach in applied in order to achieve the earlier stated objectives. The study was initiated from October 1st, 2019 to April 30th, 2020. Simple random sampling (probability) sample of (240) Pupils study In primary school at Al-Rusafa first directorate schools in Baghdad City.
Results: The study re
This study examines the removal of ciprofloxacin in an aqueous solution using green tea silver nanoparticles (Ag-NPs). The synthesized Ag-NPs have been classified by the different techniques of SEM, AFM, BET, FTIR, and Zeta potential. Spherical nanoparticles with average sizes of 32 nm and a surface area of 1.2387m2/g are found to be silver nanoparticles. The results showed that the ciprofloxacin removal efficiency depends on the initial pH (2.5-10), CIP (2-15 mg/L), temperature (20-50°C), time (0-180 min), and Ag-NPs dosage (0.1-1g/L). Batch experiments revealed that the removal rate with ratio (1:1) (w/w) were 52%, and 79.8% of the 10 mg/L of CIP at 60, and 180 minutes, respectively with optimal pH=4. Kinetic models for adsorpti
... Show More